Example: quiz answers

TEMPSENS - compensating cables

Teflon cables cables for Temperature Kapton cables Sensor & Instrumentation PVC cables Silicon cables Fibre Glass cables TEMPSENS . INSTRUMENTS. w w w. t e m p s e n s i n d i a . c o m w w w. c o m p e n s a t i n g c a b l e s . n e t THERMOCOUPLE cables . In most cases thermocouples are connected to other processing instruments by connecting cables . Connecting cables are divided into compensating cables and extension cables . These can again be divided into solid and stranded conductors. Extension cables are connecting cables with conductors made of thermocouple material, of the same material as the thermocouple itself. Extension cables therefore are subject to the same accuracy limits as the thermocouples.

TEMPSENS In most cases thermocouples are connected to other processing instruments by connecting cables. Connecting cables are divided into compensating cables and

Tags:

  Tempsens

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of TEMPSENS - compensating cables

1 Teflon cables cables for Temperature Kapton cables Sensor & Instrumentation PVC cables Silicon cables Fibre Glass cables TEMPSENS . INSTRUMENTS. w w w. t e m p s e n s i n d i a . c o m w w w. c o m p e n s a t i n g c a b l e s . n e t THERMOCOUPLE cables . In most cases thermocouples are connected to other processing instruments by connecting cables . Connecting cables are divided into compensating cables and extension cables . These can again be divided into solid and stranded conductors. Extension cables are connecting cables with conductors made of thermocouple material, of the same material as the thermocouple itself. Extension cables therefore are subject to the same accuracy limits as the thermocouples.

2 Extension cables are marked with an X behind the identification letter for the thermocouple. For example, KX means that the cable is an extension cable / insulated thermocouple wire for the thermocouple type K (NiCr-Ni). Compensation cables are connecting cables with conductors made of materials which only in a limited temperature range have the same thermoelectric properties as the thermocouple itself. compensating cables are marked with a C behind the identification letter for the thermocouple. For example, KC means that the cable is a compensating cable for the thermocouple type K. The insulation of the conductors as well as of the sheaths can be made of a variety of materials.

3 The following criteria must be taken into consideration when selecting the appropriate material: chemical and mechanical resistance against the ambient conditions, temperature range, insulation resistance, flexibility, outside diameter, screening etc. Apart from that there is a large number of cable types available as compensating cables or extension cables as well as those with more than two inner conductors. Many special designs are available upon request, most of them on a short term basis. RTD cables . RTD Cable are used to carry the RTD signals to the control room or field mounted instruments. Depending on the configuration, they are available in three ?

4 Wire four wire for simplex and ; six and eight wire for duplex Thermocouples & RTDs RTD. Mechanical Durability ? Two wire cables are also available on demand. The conductor normally used for RTD cable is Nickle Special cables Available on Request ? Plated Copper (NPC) or Silver Plated Copper (SPC) or Standard cables Available in Stock ? Bare Copper (BC). Calibration Certificate Provided. ? TEMPSENS . Colour Code & Wire Insulation COLOUR CODE OF THERMOCOUPLE EXTENSION AND compensating cables . IEC ANSI JIS. AMERICAN JAPANESE. THERMOCOUPLE CONDUCTOR INTERNATIONAL TO TO. JIS C 1610-1981 TOLERANCE CLASS CABLE. CONDUCTOR COLOUR CODE TEMPERATURE. COMBINATION EXTENSION compensating TO IEC 5843:1989 RANGE C.

5 TYPE CABLE CABLE 1 2. KX 60 V ( C) 100 V ( C) -25 C TO +200 C. K KCA 100 V ( C) -0 C TO +150 C. KCB 100 V ( C) -0 C TO +100 C. T TX 30 V ( C) 60 V ( C) -25 C TO +100 C. J JX 85 V ( C) 140 V ( C) -25 C TO +200 C. NX 60 V ( C) 100 V ( C) -25 C TO +200 C. N. NC 100 V ( C) -0 C TO +150 C. E EX 120 V ( C) 200 V ( C) -25 C TO +200 C. R RCA 30 V ( C) 0 C TO +100 C. RCB 60 V ( C) 0 C TO +200 C. SCA 30 V ( C) 0 C TO +100 C. S. SCB 60 V ( C) 0 C TO +200 C. B BC. Table 1. WIRE INSULATION IDENTIFICATION & APPLICATION GUIDE. INSULATION RESISTANCE TO: INSULATION APPEARANCE OF TEMPERATURE RANGE ABRASION WATER. FLEXIBILITY. CODE OVERALL CONDUCTORS THERMOCOUPLE GRADE WIRE INSULATION RESISTANCE SUBMERSION.

6 FLAME HUMIDITY. Polyvinyl Polyvinyl P Chloride (PVC). Chloride (PVC). -40 to 105 C Good Excellent Good Good Good PTFE PTFE. T or PFA/FEP. or PFA/FEP. -267 to 260 C Excellent Good Excellent Excellent Excellent K Kapton Kapton -267 to 316 C Excellent Good Good Good Excellent S Silicon Silicon -40 to 200 C Good Good Excellent Excellent Excellent Fiber PTFE/PFA. F Glass Braid or Fiber Glass -73 to 260 C Good Good Excellent Excellent Excellent CF Ceramic Fiber Ceramic Fiber -72 to 871 C Poor Good Poor Excellent Excellent SF Silica Silica -73 to 1038 C Poor Good Poor Excellent Fair Table 2. TEMPSENS . T Thermocouple cables Teflon H cables with a Teflon insulation are suited for dry, moist and wet rooms and high mechanical strain at high ambient temperatures.

7 Teflon-insulated cables can be laid outdoors without any problems. They can be laid firmly or flexibly. In the case of flexible laying tensile stress must be avoided. E. G). n (SW. io m at l e al m ag ul R. er ia ns Gu ov ed nd m rd ri r ist m de n tr a cto to to ti o Sq tw co uc uc du s la s of ea nd nd te pe n t/. m su Co No Fla No Ar Ite Co Ty Co In T10 7 36 Teflon Twisted - Rejects electromagnatic M Twisted Pair T11 7 32 Teflon Twisted interference Teflon Conductor T12 3 22 Teflon Twisted - T20 7 36 Teflon Flat Teflon Oval shaped for Flat. For Twisted O T21. T22. 1. 7. 22. 32. Teflon Teflon Flat Flat Teflon Teflon pair lay visible throughout the seam, rejects EMI.

8 Gas steam and T23 14 36 Teflon Flat Teflon water tight insulation. T24 3 22 Teflon Flat Teflon Teflon - Teflon C Teflon Teflon Conductor T25. T26. 7. 1. 36. 22. Teflon Teflon Twisted Twisted Teflon Teflon T27 7 32 Teflon Twisted Teflon T28 14 36 Teflon Twisted Teflon O T29. T40. 3. 7. 22. 36. Teflon Teflon Twisted Flat Teflon Teflon Round Section, Gas, steam and T41 1 22 Teflon Flat Teflon water tight; good mechenical T42 7 32 Teflon Flat Teflon strength. U T43 14 36 Teflon Flat Teflon T44 3 22 Teflon Flat Teflon Teflon - Teflon - T45 7 36 Teflon Twisted Teflon Steel Teflon Teflon Conductor Steel Braiding T46 1 22 Teflon Twisted Teflon P Braiding T47 7 32 Teflon Twisted Teflon T48 14 36 Teflon Twisted Teflon T49 3 22 Teflon Twisted Teflon L T50.

9 T51. 7. 1. 36. 22. Teflon Teflon Flat Flat Teflon Teflon Round section, rejects EMI & ESI. Gas, steam and water tight. T52 7 32 Teflon Flat Teflon T53 14 36 Teflon Flat Teflon E Teflon - Copper Screening - T54. Teflon T55. 3. 7. 22. 36. Teflon Teflon Flat Twisted Teflon Teflon Teflon Copper Teflon Conductor T56 1 22 Teflon Twisted Teflon Screening T57 7 32 Teflon Twisted Teflon T58 14 36 Teflon Twisted Teflon T59 3 22 Teflon Twisted Teflon Kapton Kapton, a kind of polyimide material, has very similar chemical properties like Teflon. Unlike Teflon, Kapton can be processed to very thin foils of very high tensile strength. It has almost no fluidity, but a high elasticity.

10 Kapton can practically not be glued to other materials. C Like glass fibre-insulated cables Kapton-insulated cables are mainly used for high temperatures in a dry environment. They have excellent electrical and mechanical properties. cables should be laid firmly as a standard and flexibly as an exception. Tensile stress cannot be tolerated. They are not suited for permanent A bending and kinks must be avoided during installation K10 7 36 Kapton Flat Kapton Good temperature witstanding. B Kapton Kapton Conductor Kapton - Kapton K11. K12. 7. 1. 36. 22. Kapton Flat Kapton Gas, steam and water tight. Kapton Twisted Kapton Lower diameter L Ordering Code T10 - KX - 1 - IEC.


Related search queries