Example: marketing

The 2000Handbook A C B - F & I Industries

The 2000 HandbookAPOWERCDATABPYROLEXO fficial Cable Supplier of the 2000 Olympic GamesSAFETY WARNINGC ables are insulated and sheathed with stable materials which may contain certain toxic substances including lead. Insulation and sheathing materials should not bechewed or must be installed in accordance with the requirements of Section 3 Selection and Installation of Wiring Systems in the latest issue of AS/NZS3000 or the appropriate ruling standard in the country of installation. Cables must also beconnected by a licensed electrician, as ruled in the state or country of particular your attention is drawn to Section of the Wiring Rules (AS/NZS3000) Protection for requirements of (current edition) differ dramatically fromthose in the 1991 edition of AS3000.

SAFETY WARNING Cables are insulated and sheathed with stable materials which may contain certain toxic substances including …

Tags:

  Sheathed, Insulated, The 2000handbook a c b, 2000handbook, Insulated and sheathed

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of The 2000Handbook A C B - F & I Industries

1 The 2000 HandbookAPOWERCDATABPYROLEXO fficial Cable Supplier of the 2000 Olympic GamesSAFETY WARNINGC ables are insulated and sheathed with stable materials which may contain certain toxic substances including lead. Insulation and sheathing materials should not bechewed or must be installed in accordance with the requirements of Section 3 Selection and Installation of Wiring Systems in the latest issue of AS/NZS3000 or the appropriate ruling standard in the country of installation. Cables must also beconnected by a licensed electrician, as ruled in the state or country of particular your attention is drawn to Section of the Wiring Rules (AS/NZS3000) Protection for requirements of (current edition) differ dramatically fromthose in the 1991 edition of AS3000.

2 While the intent to enforce safe design andinstallation practices is the same, the new standard defines the requirements ratherthan specifying solutions. Designers and installers can be assured the productsprovided by Olex Cables meet the requirements of the relevant standards, but mustensure appropriate selection of cables and components for any electrical AREASI nstallation of wiring and fittings for hazardous areas, flammable or explosivegas, liquid, dust or solids must comply with Section Hazardous Areas, ofAS/NZS3000, and other relevant Australian Standards for specific hazards NOTEPVC 90 C THERMAL RATINGThe current-carrying capacities for thermoplastic cables, including flexible cordsused as fixed wiring.

3 insulated with V-90 and V-90HT PVC compounds have beenbased on a conductor operating temperature of 75 C because of the likelihood ofthermal deformation of these cable types in the temperature range 90 to 105 C (refer Table 1 Note 2).Olex Cables is a division of Australian Cables Pty Ltd. 087 542 4 POWER CABLE1 CorePVC insulated Copper51 CorePVC/PVC Copper61 CoreXLPE/PVC Copper & Aluminium72 & 3 CorePVC/PVC Flat Copper82 & 3 Core+EarthPVC/PVC Flat Copper92 & 3 Core+EarthPVC/PVC Circular Copper102 & 3 Core+EarthXLPE/PVC Circular Copper 114 Core+EarthPVC/PVC Circular Copper124 Core+EarthXLPE/PVC Circular Copper132 & 3 Core+EarthPVC/SWA/PVC Circular Copper142 & 3 Core+EarthXLPE/SWA/PVC Circular Copper154 Core+EarthPVC/SWA/PVC Circular Copper164 Core+EarthXLPE/SWA/PVC Circular Copper17 COPPER CONTROLM ulticore+EarthPVC/PVC Circular18 Multicore+EarthPVC/SWA/PVC Circular19 NEUTRAL SCREENED2.

4 3 & 4 CorePVC/PVC Copper20 AERIAL1, 2, 3 & 4 CorePVC Copper212, 3 & 4 CoreXLPE Aluminium ABC22 FLEXIBLE CORDSCore Colours232 Core, 2, 3 & 4 Core+Earth Ordinary Duty242 Core, 2, 3 & 4 Core+Earth Heavy Duty251 CorePVC261 CoreSilicone Rubber262 CorePVC Figure 8262 & 3 CoreLight Duty26 MulticoreHeavy Duty272, 3 & 4 Core+EarthFlexolex Heavy Duty283 & 4 Core+EarthFlexolex Heavy Duty Screened29 CONTENTSH andbook 20002 FLEXIBLE CABLES1 CorePVC/TPE Welding, Power & Switchboard301 CoreCPE Welding & Power31 WeldingCurrent Ratings32 VAROLEX 3 Core+3 EarthsXLPE/PVC Copper33 PYROLEX FIRE RATED1 CoreES110342, 3, 4 CoreMulticore D&W35 INSTRUMENTATION CABLE DEKORON Pairs36 Pairs SWA37 COMMUNICATIONS CABLELANC ategory 3 16 MHzPVC insulated Copper38 Category 5 StandardPVC insulated Copper39 Category 5 ExternalPVC insulated Copper39 Category 5ePVC insulated Copper40 Category 5e ExternalPVC insulated Copper40 Proposed Category 6 DataTwist 35041 Category 6 MediaTwist41 Thin EthernetPVC insulated Copper42100 Ohm TwinaxialPVC insulated Copper4278 Ohm TwinaxialBlue Hose42 FIBREI ndoor/Outdoor Riser43 Internal Light Duty Riser44 Internal Heavy Duty Riser44 External Single TubeConstruction45 External Loose TubeSingle Mode & Multi Mode46

5 External Armoured Loose Tube Cable47 TELEPHONE CABLEI nternal48 Underground External49 External Jelly Filled50 External Jelly Filled & Moisture Barrier51 Aerial51 Telstra Approved Ex ternal52 Jumper Wire53 Jumper WireCategory 553 CONTENTSDATA CABLEA udio Control54RS485 Screened DataLow Capacitance55RS232 Screened Data55RS232 Screened DataMid Capacitance56 ISDN Foil or Braid 120 Ohm56 SCSI Cables57 Traffic Detector Cable57 SECURITY CABLESM ulticore Circular 58 Flat (Figure 8)58 MICROPHONE59 ACCESSORIESALCO Earth Tags60 ALCO Locknuts60 ALCO PVC Shrouds61 Clipsal A4 Industrial Glands61 Glands UA, UG, UFPR, G, WG, FLPW62 67 CURRENT RATINGSF lexible Cords68 PVC Aerial CablesCopper69 Flexible & Welding Cables70 Single Phase2 x 1 Core PVC, XLPE71 72 Single Phase2 Core PVC, XLPE73 74 Three Phase3 x 1 Core PVC, XLPE75 76 Three Phase3 & 4 Core PVC.

6 XLPE77 78 GENERALC able Selection79 80 Installation81 Minimum Size of Copper Earthing Conductors82 Maximum Operating Resistance833 Phase & Conductor Size Conversion85 Bending Radii86 Diameter to Cross-sectional Area87 Number of Cables in Conduit88 Cables in Conduit Space Factors89 Pulling Tension89 Abbreviations90 CONTENTS34 Olex Envirolex cables are an extensive range of enhanced performancecables for the construction industry engineered to dramatically reduceenvironmental impact, particularly under fire conditions, while retainingthe excellent mechanical and electrical properties designed into Olex cables. Olex uses a variety of inorganically filled polyolefin basedmaterials to engineer the cables in the Envirolex range to meet a widevariety of end uses and performance of Olex Envirolex cables Conductor range up to 630mm2 Cable types from building wires to SWA, to multicore control 90 C rated for superior thermal performance Improved performance under fire conditions: Flame retardant/self-extinguishing Reduced acid, gas and smoke generation Non-corrosive in fire situations Reduced toxicity of fumes during fire Halogen free ( no chlorine, bromine etc.)

7 Lead free No special termination or installation requirements Made in accordance with Australian Standards Envirolex cables have been tested according to and comply with therequirements of the single and bunched flame tests (as applicable)specified in products include readily strippable cables for general construction purposes as well as the tougher products commonly found in cables with higher fire performance materials are used as alternatives to all low voltage power and control cables (refer tables on pages 5 to 23). Cables are available on request, subject to minimum production NominalNominalNominalApproximateProductc onductorinsulationoverallmasscodeareathi cknessdiametermm2 core PVC insulated copper earth : Compacted conductor.

8 Other temperature grades subject to minimum production core, PVC insulated , unsheathed to , Copper conductors, 90 INSULATEDPOWERNEWSTANDARDAS/NZS5000 NominalNominalNominalNominal ApproximateProductconductorinsulationshe athoverallmasscodeareathickness thicknessdiametermm2 : Compacted core, PVC insulated , PVC sheathed to AS/NZS5000, Copper conductors, 90 C. to 25mm2450/750V to 35 to to BDBA17 BDBA18 BDBA19 BDBA20 BDBA22 : Compacted Copper conductors. Al Aluminium INSULATEDPOWER7 Single core, XLPE insulated , PVC sheathed to , Copper and Aluminium conductors, 90 & 3 core flat, 450/750V PVC insulated , PVC sheathed to , Copper conductors, 90 FLATN ominalConductorNominalNominalApproximate Productconductortypeearthoverallmasscode areaareadimensionsmm2mm2 :For insulation thickness refer to page & 3 core+earth flat, 450/750V PVC insulated , PVC sheathed to , Copper conductors, 90 FLATPOWERN ominal ConductorNominalNominalApproximateProduc tconductortypeearthoverallmasscodeareaar eadimensionsmm2mm2mmkg/100m2C+ +.

9 For insulation thickness refer to page Earth NominalApproximateProductconductor conductoroverallmasscodeareaareadiameter mm2mm2mmkg/100m2C+ 3C+ : Compacted conductor. Earth cores smaller than 25mm2 are not +E, 35mm2and above, subject to minimum production run. For insulation thickness refer to page & 3 core+earth, circular, PVC insulated , PVC sheathed to AS/NZS5000, Copper conductors, 90 C. to 6mm2450/750V to 10 to to CIRCN ominalMainSheathNominalApproximateProduc tconductorconductorthickness overallmasscodeareatypediametermm2mmmmkg /100m2C+ + : Compacted conductor.

10 Earth cores smaller than 25mm2 are not compactedFor insulation thickness refer to page 7. 31 2core (3 core+reduced neutral with or without earth) available on request subject to minimum production & 3 core+earth, circular, XLPE insulated , PVC sheathed to , Copper conductors, 90 INSULATEDPOWERN ominalEarthNominalApproximateProductcond uctorconductoroverallmasscodeareaareadia metermm2mm2mmkg/100m4C+ : Compacted conductor. Earth cores smaller than 25mm2are not insulation thickness refer to page core+earth, circular, PVC insulated , PVC sheathed to AS/NZS5000, Copper conductors, 90 C. to 6mm2450/750V to 10 to to CIRC12 NEWSTANDARDAS/NZS5000 NEWSTANDARDAS/NZS5000134 core+earth, circular, XLPE insulated , PVC sheathed to , Copper conductors, 90 INSULATEDPOWERN ominalMainSheathNominal ApproximateProductconductorconductorthic kness overallmasscodeareatypediametermm2mmmmkg /100m4C+ : Compacted conductor.


Related search queries