Example: confidence

The AeroTherm Series Heat Pump water heater …

The AeroTherm Series Heat Pump water heater offers advanced technology and low cost to American Manufacturing, Wholesale Distribution, and Professional F * *181818 EnergyFactor(EF) Rating(FHR)656994195195235591/8591/8711/ 8603/4603/4731/2213/4213/425383/4383/450 3/8 FFloor toT& *Energy Factor and First Hour Rating are based on latest AHRI Directory OPERATIONO perating Sound Level55 DBA Average POWER / RATINGSE lectrical Circuit Required208V/240V 60 Hz Dedicated 30 Amp Min. Electrical Consumption - Lower Element4,000 Watts ( EF = 4,500 Watts)Electrical Consumption - Upper Element4,500 WattsElectrical Consumption Heat Pump4,500 Watts Maximum Heating;550 Watts Minimum Heating Energy Factor (hybrid mode)Up to Hour Rating (FHR)Up to 94 gallonsOperating Air Temperature RangeHeat Pump 35 F to 120 F (Unit operates)

The AeroTherm™ Series Heat Pump water heater offers advanced technology and low cost operation. Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

Tags:

  Pumps, Water, Water pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of The AeroTherm Series Heat Pump water heater …

1 The AeroTherm Series Heat Pump water heater offers advanced technology and low cost to American Manufacturing, Wholesale Distribution, and Professional F * *181818 EnergyFactor(EF) Rating(FHR)656994195195235591/8591/8711/ 8603/4603/4731/2213/4213/425383/4383/450 3/8 FFloor toT& *Energy Factor and First Hour Rating are based on latest AHRI Directory OPERATIONO perating Sound Level55 DBA Average POWER / RATINGSE lectrical Circuit Required208V/240V 60 Hz Dedicated 30 Amp Min. Electrical Consumption - Lower Element4,000 Watts ( EF = 4,500 Watts)Electrical Consumption - Upper Element4,500 WattsElectrical Consumption Heat Pump4,500 Watts Maximum Heating.

2 550 Watts Minimum Heating Energy Factor (hybrid mode)Up to Hour Rating (FHR)Up to 94 gallonsOperating Air Temperature RangeHeat Pump 35 F to 120 F (Unit operates in Standard/Electric Mode outside of this range) Operating water Pressure150 PSI Maximum Working Pressure(30-80 PSI recommended) ACEFDBS pecs at a GlanceATHRMB-0715 Dimensions and specifications subject to change without notice inaccordance with our policy of continuous product Bradford White AeroTherm Series water heaters combinethe installation and servicing features valued by plumbingprofessionals with the energy and cost saving benefits importantto today s energy conscious consumer.

3 Smart for YouFor plumbing professionals, the AeroTherm Series features top water connections andconvenient height and weight for quick and easy replacements and installations. The productcan also be laid on its side for greater transportation flexibility. And AeroTherm s integratedsmart control panel includes detailed diagnostic information for ease of serviceability andquick and accurate diagnostics. Just as important, the AeroTherm Series adds anothergreat line of Bradford White products you can offer your for CustomersENERGY STAR certified, AeroTherm Series water heaters are eligible for most rebateprograms throughout the country resulting in initial savings to the consumer.

4 Efficiencies upto EF (Energy Factor) result in significant energy and money savings throughout productlifetime. First hour delivery ratings up to 92-gallons per hour and ultra-quiet operation ensureconsumers get exceptional performance to meet their demands for hot water . And with fouruser-selectable operation modes (Heat Pump, Hybrid, Electric, Vacation), the newAeoTherm Series gives consumers greater control over their water heater s energyconsumption. The AeroTherm Series also comes standard with a 10-year limited AeroTherm utilizes both heat-pump technology (1) and back-up electric heatingelements (2) to heat water .

5 This integrated system helps to drive the AeroTherm 'seconomical and efficient operation. During heat pump operation, a fan (3) draws heatfrom the air into a compressor (4) and evaporator (5) to heat refrigerant. Once heated,the refrigerant travels through a coil (6) that fully surrounds the water storage is directly transferred to the water in the tank (7). The AeroTherm Series heatpump water heater provides considerable energy efficiency while greatlyreducing the cost of water AeroTherm Series control panel provides detaileddiagnostic information including water heater fault codes,tank codes, need to assess codes, and heat pump functions allow you to monitor the status oftemperature-sensing thermistors and heating components.

6 User friendly, easy to read display LED s clearly indicate the current operating mode Easy to change the temperature or operating mode Adjustments of one degree increments from 100 to140 degrees Fahrenheit Display communicates current status, mode and set point,and displays error messages when applicableWhat Makes It SmartThe AeroTherm SeriesSmart Control Panel Get The AeroTherm Series Heat Pump water for You and Smart for Your Customers. 50- and 80-gallon capacities - comparablereplacements for 40-, 50-, or 80-gallon standardelectric water heaters Provide the same amount of hot water as standardelectric 50- or 80-gallon water heaters Same footprint and electrical connections as astandard electric water heater Top water connections and a convenient height andweight for quick and easy replacements andinstallations Designed for indoor installation such as: basement,garage, closet, utility room, attic, etc.

7 Four operating modes: Heat Pump, Hybrid, Electric,and Vacation Electronic controls make it simple to change thetemperature or operating mode Northern climate tier 3 capable (RE2H50R10B andRE2H80R10B) Quiet operation 10-year limited warranty Highlights Save $403 per year inestimated annualoperating cost* Qualifies forstate andlocal utilityrebates andtax credits Exceeds ENERGYSTAR standards andprovides year-roundenergy and moneysavingsENERGY STAR QUALIFIED:12254736 Heat Pump (only) Mode Maximizes consumer savings. The most energyefficient mode as it only utilizes the heat Mode Saves while experiencing fast recovery.

8 Hybrid mode is thefactory setting combining heat pump efficiency and savings with recovery ratesof standard electric when (only) Mode Operates like a standard electric water heater , andeliminates the air flow and sound from the heat pump system when preferred(fastest recovery time, but least energy efficient).Vacation Mode Adjusts the temperature set point down to 50 F for 3-14 Modes*Information provided by the Air Conditioning,Heating and Refrigeration Institute (AHRI) andBradford White. Savings based on the estimatedannual operating cost of a standard 50-gallonelectric tank water heater using 4773 kWh peryear vs.

9 The 50-gallon, EF AeroTherm heatpump water heater using 1416 kWh per year andnational average electricity rate of 12 cents perkWh. For FTC guide information, please