The Handbook - Global expert in cables and …

The Handbook2012 EDITIONOnly the names have been changed to protect the cables that have been keeping Australians safe and secure for 30 years have a new is now the name to specify for the cables you ve always relied on where safety and security are critical to maintain circuit integrity for mains power, lighting, alarms, pumps and other essential services when under , backed by the Global resources of Nexans, Olex is, more than ever, your one-stop-shop for the most complete range of performance Pyrolex Envirolex cables are insulated and sheathed with stable materials which may contain certain toxic sub stances including lead. Insulation and sheathing materials should not be chewed or you require more detailed data regarding materials, please contact our Group Safety Manager on 03 9281 4444 or refer to our web site, cables must be installed in accordance with the requirements of Section 3 Selection and Installation of Wiring Systems in the latest issue of AS/NZS 3000 or the appropriate ruling standard in the country of installation.

Cables are insulated and sheathed with stable materials which may contain certain toxic substances including lead. Insulation and sheathing materials should not be

Tags:

  Handbook, Deal, Cable, Sheathed

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of The Handbook - Global expert in cables and …

1 The Handbook2012 EDITIONOnly the names have been changed to protect the cables that have been keeping Australians safe and secure for 30 years have a new is now the name to specify for the cables you ve always relied on where safety and security are critical to maintain circuit integrity for mains power, lighting, alarms, pumps and other essential services when under , backed by the Global resources of Nexans, Olex is, more than ever, your one-stop-shop for the most complete range of performance Pyrolex Envirolex cables are insulated and sheathed with stable materials which may contain certain toxic sub stances including lead. Insulation and sheathing materials should not be chewed or you require more detailed data regarding materials, please contact our Group Safety Manager on 03 9281 4444 or refer to our web site, cables must be installed in accordance with the requirements of Section 3 Selection and Installation of Wiring Systems in the latest issue of AS/NZS 3000 or the appropriate ruling standard in the country of installation.

2 cables must also be connected by a licensed electrician, as ruled in the state or country of installation. In particular your attention is drawn to Section of the Wiring Rules (AS/NZS 3000) Fundamental and installers can be assured the products provided by Olex meet the requirements of the relevant cable standard, but must ensure appropriate selection of cables for the electrical installation Areas Installation of wiring and fittings for hazardous areas, flammable or explosive gas, liquid, dust or solids must comply with Section Hazardous Areas, of AS/NZS 3000, and other relevant Australian Standards for specific hazards and NotePVC 90 C Thermal Rating The current carrying capacities for thermoplastic cables , including flexible cords used as fixed wiring, insulated with V-90 and V-90HT PVC compounds have been based on a conductor operating temperature of 75 C (refer AS/NZS Table 1 Note 2).

3 SAFETYWARNINGA lsecure Envirolex cables 7 Low Voltage1 Core PVC Insulated 9 1 Core PVC SDI 10 1 Core XLPE/PVC Single Core 11 2 & 3 Core PVC Flat 12 2 & 3 Core+Earth PVC Flat 13 2 & 3 Core+Earth PVC Circular 14 2 & 3 Core+Earth XLPE/PVC Multicore 15 4 Core+Earth PVC Circular 16 4 Core+Earth XLPE/PVC Multicore 17 2 & 3 Core+Earth PVC SWA Circular 18 2 & 3 Core+Earth XLPE/PVC SWA Multicore 19 4 Core+Earth PVC SWA Circular 20 4 Core+Earth XLPE/PVC SWA Multicore 21 Multicore+Earth PVC Control 22 Multicore+Earth PVC SWA Control 23 4 Core XLPE URD Power 24 2, 3 & 4 Core XLPE Aerial Bundled 25 Industrial2 Core, 2, 3 & 4 Core+Earth Powerlex PVC OD Cords 28 2 Core, 2, 3 & 4 Core+Earth Powerlex PVC HD Cords 29 1, 2 & 3 Core Powerlex PVC Cords 30 1 Core Versolex HD Single Core 31 2, 3 & 4 Core Versolex HD Unscreened 32 5 Core Versolex HD Unscreened 33 4 & 5 Core Versolex HD Braid Screened 34 1 Core Titanex Single Core 352 Core, Multicore+Earth Titanex Multi Core 362.

4 3 & 4 Core+Earth Flexolex HD Unscreened 37 3 & 4 Core+Earth Flexolex HD Screened 38 3 Core+3 Earths Varolex VSD/EMC 39 Multicore+Earth PVC Flexible Control 40-41 Multicore+Earth PVC/EMC Flexible Control 42 1 Core Silicone Single Core 43 Multicore Silicone Multicore 44 Pairs Instrolex Instrumentation 45 Pairs Instrolex Instrumentation SWA 46 CONTENTSThe 2012 Handbook34 Fire Performance1 Core Alsecure Premium Ceramifiable Single Core Flex 48 Multicore Alsecure Premium Ceramifiable Multicore 49 Single & Multipair Alsecure Premium Ceramifiable Instrumentation & Data 51 Data/CommsSecurity 53 Security/Audio 54 LAN 55 Coaxial 56-57 Optical Fibre 58 Telephone Internal 59 Telephone External 60 PVC Garden Lighting 61 Fire Alarm 62 Data 63 AccessoriesAlco Metal cable Glands EMC, UW, HUW, AW, HAW 65-69 Alco Earth Tags Nickel Plated 70 Alco Gland Shrouds 71 CONTENTS4 The 2012 Handbook5 Current RatingsFlexible cable Cord Colours 72 PVC Flexible Cords 73 Versolex & Flexolex Flexible Installation 74 Welding 75 Aluminium Aerial 76 Copper Aerial 77 Single Phase 2x1 Core PVC, XLPE, 110 C 78-80 Single Phase 2 Core PVC, XLPE 81-82 Three Phase 3x1 Core PVC, XLPE, 110 C 83-85 Three Phase 3 & 4 Core PVC, XLPE.

5 110 C 86-88 General DataCable Selection 89-91 cable Installation 92 Minimum Size of Copper Earthing Conductors 93 Maximum Operating Temperatures 93DC Resistance 943 Phase Formulae & Conductor Size Conversion 96 Bending Radii & Motor Current 97 Number of cables in Conduit 98-99 cables in Conduit Space Factors 100 Pulling Tension 100 Abbreviations 101 LocationsLocations 102 The Olex cable RangeHandbook Subscription 107 The Olex cable Range 1086 ALSECURE ENVIROLEX CABLESA lsecure Envirolex cables are an extensive range of enhanced performance cables for the construction industry engineered to dramatically reduce environmental impact, particularly under fire conditions, while retaining the excellent mechanical and electrical properties designed into Olex cables . Olex uses a variety of inorganically filled polyolefin based materials to engineer the cables in the Alsecure Envirolex range to meet a wide variety of end uses and performance of Alsecure Envirolex cables Conductor range up to 630mm2 cable types from building wires to SWA, to multicore control 90 C rated for superior thermal performance Improved performance under fire conditions: Flame retardant/self-extinguishing Reduced acid, gas and smoke generation Non-corrosive in fire situations Reduced toxicity of fumes during fire Halogen free ( no chlorine, bromine etc.)

6 Lead free No special termination or installation requirements Made in accordance with Australian Standards Alsecure Envirolex cables have been tested according to and comply with the requirements of the single flame tests specified in AS Envirolex products include readily strippable cables for general construction purposes as well as the tougher products commonly found in cables with higher fire performance Envirolex materials can also be used as alternatives to all other low voltage power and control cables (refer tables on pages 8 to 25). cables are available on request, subject to minimum production on the Alsecure Fire Performance range of cables can be found on pages 47 to 51 of this & 3 core+earth flat, 450/750V X-90 (XLPE) insulated, HFS-90-TP sheathed to AS/NZS , copper conductors, 90 C. Note: Alsecure Envirolex cables are lead and halogen free and are suitable for green building ENVIROLEX FLAT Nom.

7 Main Nom. Nom. Earth Nominal Approx. Product cond. conductor insul. sheath cond. overall mass code area type thick. thick. area diameter mm2 mm mm mm2 mm kg/100m2C+E Solid Cu CTCP02JA002 Strand Cu CTCP05JA002 Solid Cu CTCP06JA002 Strand Cu CTCP07JA002 Strand Cu CTCP09JA002 Strand Cu CTCP11JA002 Strand Cu CTCP13JA002 Strand Cu CTCP15JA0023C+E Strand Cu ETCP05JA003 Strand Cu ETCP07JA0038 Powering where we has a proud history of cable manufacturing expertise, with more than half a century of experience in the industry. Offering a comprehensive range of low voltage power and control cables , Olex has the cable you VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM SMINI NGLOW VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM SMINI NG9 LOW VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM S MINI NG Nominal Main Nominal Nominal Approximate Product conductor conductor insulation overall mass code area type thickness diameter mm2 mm mm kg/100m Solid Cu BAAP01AA001 Solid Cu BAAP02AA001 Strand Cu BAAP03AA001 Strand Cu BAAP05AA001 Strand Cu BAAP07AA001 4 Strand Cu BAAP09AA001 6 Strand Cu BAAP11AA001 10 Strand Cu BAAP13AA001 16 Strand Cu 17 BAAP15AA001 25 Compact Cu 26 BAAC17AA001 35 Compact Cu 35 BAAC18AA001 50 Compact Cu 48 BAAC19AA001 70 Compact Cu 67 BAAC20AA001 95 Compact Cu 96

8 BAAC22AA001 120 Strand Cu 118 BAAP23AA001 150 Strand Cu 144 BAAP24AA001 185 Strand Cu 180 BAAP25AA001 240 Compact Cu 236 BAAP26AA001 300 Strand Cu 296 BAAP27AA001 400 Strand Cu 376 BAAP28AA001 500 Strand Cu 477 BAAP30AA001 630 Strand Cu 613 BAAP32AA001 Single Core PVC Insulated Copper Earth Conductor Strand Cu AATP05AA001 Strand Cu AATP07AA001 Note: Other temperature grades subject to minimum production INSULATEDS ingle core, V-90 insulated, to AS/NZS (unsheathed), copper conductors, 90 VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM S MINI NG Nominal Main Nominal Nominal Nominal Approx. Product conductor conductor insulation sheath overall mass code area type thickness thickness diameter mm2 mm mm mm kg/100m Strand Cu AABP02AA001 Strand Cu AABP05AA001 Strand Cu AABP07AA001 4 Strand Cu AABP09AA001 6 Strand Cu AABP11AA001 10 Strand Cu AABP13AA001 16 Strand Cu AABP15AA001 25 Compact Cu BABC17AA001 35 Compact Cu 43 BABC18AA001 50 Compact Cu 56 BABC19AA001 70 Compact Cu 77 BABC20AA001 95 Compact Cu 107 BABC22AA001 120 Strand Cu 130 BABP23AA001 150 Strand Cu 158 BABP24AA001 185 Strand Cu 197 BABP25AA001 240 Compact Cu 257 BABP26AA001 300 Strand Cu 320 BABP27AA001 400 Strand Cu 406 BABP28AA001 500 Strand Cu 510 BABP30AA001 630 Strand Cu 653 BABP32AA001 Single core.

9 V-90 insulated, PVC sheathed to AS/NZS 5000, copper conductors, 90 C. to 16mm2 450/750V to AS/NZS 25 to 630mm2 to AS/NZS SDI11 LOW VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM S MINI NGXLPE/PVC SINGLE CORE Nom. Main Nominal Nominal Nominal Approximate Product cond. conductor insulation sheath overall mass code area type thickness thickness diameter mm2 mm mm mm kg/100mCopper Conductor 16 Strand Cu 21 BDBP15AA001 25 Compact Cu 30 BDBC17AA001 35 Compact Cu 40 BDBC18AA001 50 Compact Cu 52 BDBC19AA001 70 Compact Cu 73 BDBC20AA001 95 Compressed Cu 101 BDBC22AA001 120 Compressed Cu 123 BDBP23AA001 150 Compressed Cu 152 BDBP24AA001 185 Compressed Cu 189 BDBP25AA001 240 Compressed Cu 246 BDBP26AA001 300 Compressed Cu 306 BDBP27AA001 400 Strand Cu 386 BDBP28AA001 500 Strand Cu 491 BDBP30AA001 630 Strand Cu 635 BDBP32AA001 Aluminium Conductor 25 Compact Al 15 BDBA17AA001 35 Compact Al 18 BDBA18AA001 50 Compact Al 23 BDBA19AA001 70 Compact Al 31 BDBA20AA001 95 Compact Al 40

10 BDBA22AA001 120 Compact Al 49 BDBA23AA001 150 Compact Al 60 BDBA24AA001 185 Compact Al 72 BDBA25AA001 240 Compact Al 91 BDBA26AA001 300 Compact Al 112 BDBA27AA001 400 Compact Al 142 BDBA28AA001 500 Compact Al 185 BDBA30AA001 630 Compact Al 233 BDBA32AA001 Single core, X-90 insulated, PVC sheathed to AS/NZS , copper or aluminium conductors, 90 VOLTAG EINDU STRIA LHIGH VOLTAG EFIRE RATE DDATA/COMM S MINI NG2 & 3 core flat, 450/750V V-90 insulated, PVC sheathed to AS/NZS , copper conductors, 90 FLAT Nom. Main Nominal Nominal Nominal Approximate Product cond. conductor insulation sheath overall mass code area type thickness thickness diameter mm2 mm mm mm kg/100m2C Solid Cu CACP02AA002 Strand Cu CACP05AA002* Strand Cu CACP07AA002 4 Strand Cu CACP09AA002 6 Strand Cu CACP11AA002 10 Strand Cu CACP13AA002 16 Strand Cu CACP15AA0023C Strand Cu EACP05AA003 Strand Cu EACP07AA003 Note: *Red sheath 450/750V version available for fire alarm wiring systems.