Example: bachelor of science

Thermal Batt Insulation Product Data Sheet - Fransyl

Product DESCRIPTIONPINK glass fibre Thermal Insulation ,inorganic, pre-formed unfacedblankets, designed for friction-fitinstallation in frame UsesGlass fibre Thermal insulationblankets may be installed in thefollowing locations: Above ground steel or wood studframed exterior walls. Interior side of below groundfoundation walls with steel orwood framing. Floors above unheated exteriorspaces and crawl spaces. Ventilated roof-spaces (or attics)above flat or sloped ceilings. Steel or wood stud framed roofparapets and curbs. Cathedral ceilings. Steel or wood stud framedinterior partitions separatingheated spaces from unheated orrefrigerated spaces. To provide Thermal resistancearound openings in a building sexterior fibre Thermal Insulation isGREENGUARD and SCS certified Post-consumer : glass materialsrecycled from construction sites(demolition work, newconstruction and renovation) andfrom consumers blue boxes.

Thermal Batt Insulation Product Data Sheet TABLE 1 - CAN/ULC-S702 Physical Property Requirements Mean thermal resistance ≥ the design thermal resistance (as stated on the product). Mean thickness ≥ design thickness and none of the individual …

Tags:

  Product, Sheet, Data, Insulation, Insulation product data sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Thermal Batt Insulation Product Data Sheet - Fransyl

1 Product DESCRIPTIONPINK glass fibre Thermal Insulation ,inorganic, pre-formed unfacedblankets, designed for friction-fitinstallation in frame UsesGlass fibre Thermal insulationblankets may be installed in thefollowing locations: Above ground steel or wood studframed exterior walls. Interior side of below groundfoundation walls with steel orwood framing. Floors above unheated exteriorspaces and crawl spaces. Ventilated roof-spaces (or attics)above flat or sloped ceilings. Steel or wood stud framed roofparapets and curbs. Cathedral ceilings. Steel or wood stud framedinterior partitions separatingheated spaces from unheated orrefrigerated spaces. To provide Thermal resistancearound openings in a building sexterior fibre Thermal Insulation isGREENGUARD and SCS certified Post-consumer : glass materialsrecycled from construction sites(demolition work, newconstruction and renovation) andfrom consumers blue boxes.

2 Post-industrial (or pre-consumer ): glass recycled fromglass manufacturing plants waste(glass containers, flat glass and others).Includes materials that contribute to the reduction of dust and staticelectricity, ensuring a clean and easy DATAA pplicable Codes and StandardsNational Building Code of Canada1995 or 2005 Volume 2, Division B Meets requirements of (2)(including all subsequent revisions).Canadian Standards (UnderwritersLaboratories of Canada (ULC)) CAN/ULC-S702, Standard forThermal Insulation , Mineral (Glass)Fibre, for Buildings (supersedesCSA A101-M1983); Type 1, pre-formed unfaced Insulation . CAN/ULC-S102, StandardMethod of Test for SurfaceBurning Characteristics of BuildingMaterials and Assemblies. CAN4-S114, Standard Method of Test for Determination of Non-Combustibility in BuildingMaterials; Type 1 pre-formed glassfibre Thermal Insulation meets therequirements of this Canada/Workplace HazardousMaterials Information System (WHMIS).

3 Visit for a currentcopy of the Material Safety data Sheet (MSDS) for Low Density Fiber GlassInsulation unfaced .for its green content (refer toTECHNICAL data ) and cancontribute to obtaining LEEDTMC ertification credits when used asthermal Insulation in a buildingsubmitted to the LEEDCANADA-NCGreen Building Rating System (referto TABLE 2).LimitationsOwens Corning does notrecommendusing PINK FIBERGLAST hermal Insulation in the followinglocations: On the exterior side ofintermediate sheathing of cavitywalls and other locations exposedto water, humidity and wind. On the exterior side offoundation walls, whether aboveor below ground level. In locations where no vapourretarder is provided on the warmside of the Insulation . Where it is impossible to provideclearances required by Codes andRegulations (building, electrical, gasand oil) between the insulationand heat-emitting appliances,chimneys, pipes, conduits andvents to these appliances (at least50 mm) and between insulationand recessed light fixtures that arenot encased in CSA-approvedinsulated boxes (at least 75 mm).

4 PINK FIBERGLAST hermal Insulationcan also enhance the acousticalperformance of an acousticseparation, but Owens Corningrecommends using QuietZone Acoustic Batt Insulation ; seeQUIETZONEData Sheet 09 , bonded glass fibre,manufactured from recycledmaterials obtained from two sources: Product data Sheet07 21 FIBERGLAS Thermal Batt InsulationThermal resistanceThicknessWidthLengthSurface burning characteristicsSmoulder resistance(1)Refer to CAN/ULC-S702, TABLE 207 21 FIBERGLAS Thermal Batt InsulationProduct data SheetTABLE 1 - CAN/ULC-S702 Physical Property RequirementsMean Thermal resistance the designthermal resistance (as stated on theproduct).Mean thickness design thickness andnone of the individual thickness less than 90% of the design thickness. 0%, + 3% 1%, + 3%Flame spread classification max 25;smoke developed max mean mass loss shall not exceed5% and none of the individual samplesshall exceed 10%.CompliesCompliesCompliesCompliesFlam e spread: 15 Smoke contributed: < 5 CompliesPropertiesCAN/ULC-S702 requirements for pre-formed unfaced Insulation (1)PINK FIBERGLASI nsulationPhysical PropertiesCanadian Construction MaterialsCentre (CCMC) Product EvaluationPINK FIBERGLAST hermal Insulationis evaluated as a Product meetingrequirements of NBC 2005 andCAN/ULC-S702.

5 data valid for productsmanufactured at facilities inEdmonton (Alberta), Scarborough(Ontario) and Candiac (Quebec). Product Evaluation ListingNumber by IndependentThird Party Agencies - Recycled Content and IndoorAir Quality StandardsSCS Certification (ScientificCertification Systems) for recycledmaterials based on environmentalclaims certification program: 35% minimum certified recycledmaterials content distributed as follows: 26% post-industrial (or pre-consumer ) recycled materialscontent; average for all NorthAmerican manufacturing plants; 9% post consumer recycledmaterials content;Recycled Materials ContentDeclared by Owens Corning forits Canadian ManufacturingFacilitiesThe average recycled materialscontent is at least 60% for thefollowing Canadian manufacturingfacilities: Candiac (Quebec): 0% post-industrial (or pre-consumer ) recycled materials; 60% + post-consumer recycled materials. Scarborough (Ontario): 10% post-industrial (or pre-consumer ) recycled materials; 50% + post-consumer recycled materials.

6 Edmonton (Alberta): 0% post-industrial (or pre-consumer ) recycled materials; 60% + post-consumer recycled materials. Certificate of Achievement : manufactured by Owens Corning(various forms and sizes) . For up-to-date Certification informationgo to FIBERGLAS Thermal Insulation isGREENGUARD Certified to meetstringent indoor air quality is in accordance withthe GREENGUARD Standard forLow Emitting Products: Individual VOCs < TLV ppm Total mg/m3 Total ppm Respirable mg/m3 GREENGUARD Indoor Air QualityCertified certification: OwensCorning PINK FIBERGLAST hermalInsulation. For up-to-dateCertification information go (1)Refer to the LEED- Green Building Rating Systemfor new construction and important renovations, LEEDC anada-NC , as promoted by the CaGBC.(2)Model National Energy Code for Buildings 1997.(3)The recycled content of a material or furniture must be determined by dividing the weight of the recycled content of the item by the total weight of the whole item, then by multiplying the resulting ratio by the total cost of the 21 FIBERGLAS Thermal Batt InsulationProduct data SheetConsult the Product Safety DataSheet (MSDS) (see above).

7 PreparationWhere there are soffit vents, takeappropriate measures to preventthermal batt Insulation from blockingthe air ventilation. Install OwensCorning raft-R-mate attic cavities to be insulated havebeen inspected, notably: The installation of the supportmaterials located on the cold side(plywood or gypsum boards orother sheathing type panels). Mechanical and electrical servicelines passing in or through thewall Insulation must beinstalled so that at least one face isin full and continuous contact withcladding, sheathing, or some othermembrane. Where blanket-typeEA(Energy andAtmosphere) Credit 1for energy performanceoptimization of new orexisting (Materials andResources) Credits for recycledmaterials content.(3)MR(Materials andResources) Credits & for locallyor regionallyproduced (Innovation & DesignProcess) Credit energy costreduction compared toNMECB(2)and ASHRAE/IESNA : 1 to 10 points, basedon % reduction.

8 Post-consumer recycled content plusone half post-industrial recycled materials:1 point for at least and 2 pointsfor at least 15%.Materials regionallyextracted andmanufactured: 1 point forat least 10% and 2 pointsfor at least 20%.1-4 points dependent oneffectiveness of theinnovation being contributessignificantly to thereduction of a building senergy demand. Globalcontribution depends on the design RSI FIBERGLAST hermalBatt Insulation (Candiac0% post-industrial, 60% +post-consumer ; Scarborough10% post-industrial, 50% +post-consumer ; Edmonton0% post-industrial, 60% +post-consumer).Canadian Insulation productsoriginating from the 3 glassfibre plants (Candiac,Scarborough, Edmonton)contribute towards creditsfor this fibre thermalinsulation is also effectivein reducing noise transferthrough buildingassemblies. The Project Manageris responsible forthe energy analysisconcerning the globalenergy efficiency ofthe building (ex.)

9 LEED standard form letter).Recycled content certificationsby Scientific CertificationSystems for PINK FIBERGLAST hermal Batt Insulation (>35%North American average).Minimum 60% average forCanadian with local salesrepresentatives todetermine the Product with local technicalrepresentative for and performance criteriaRequirements to meet toobtain a voluntary creditInsulation s contributionto the performanceAdditional commentsCONTRIBUTION TO LEEDCANADA CERTIFICATIONTABLE 2: Contribution of Owens Corning Canada s PINK FIBERGLAST hermal Batt Insulation Toward LEEDCANADA-NC credits(1).IDENTIFICATION ANDAVAILABLE SIZESP ackage IdentificationEach bag of Insulation is labelledwith information as required byCAN/ULC-S702 along with theCCMC Evaluation Listing Measures:Applicator ProtectionEnsure applicator s personnel wearsprotection equipment such asbreathing masks (dust-proof typemasks prescribed in Material SafetyData Sheet ), face and eyeprotection (safety goggles or eyeglasses) and skin protection (gloves,long-sleeved shirts and pants).

10 ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ " " " " "** " "121420/192224**2831 WOOD FRAMEWOOD FRAMESTEEL FRAMEWOOD FRAMEWOOD FRAMESTEEL FRAMEWOOD 3 - Typical Physical Properties & *4748*484847474748*474748*48484747474748 484848484848484848mm11941219119412191219 1219119411941194121911941194121912191219 1194119411941194121912191219121912191219 1219121912191219sq. ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ " "267279* R12 and R20 48" long batts for wood frame construction is available in Qu bec only. ** R24 available in Ontario only.^ coverage based on SpaceSaver packaging formatinsulation is installed in attics underflat or sloped roofs, or betweenrafters in cathedral ceilings, provideat least 65 mm (2 1/2") air spacebetween the cold side of theinsulation blanket and the roof deck Insulation must be replaced orleft to dry by providing an adequateair circulation. If the Insulation is notcompressed, it will recover its initialthermal AND COSTCost EstimatesCost estimates are readily availablefrom a physical descriptionconsisting of drawings and a briefspecification based on theinformation contained in thisProduct data SERVICESO wens Corning publishes manytechnical bulletins and offers in-depth consultation services anddew point analysis to help youselect the appropriate products for your designs and prepare details, and specifications.


Related search queries