Example: quiz answers

Thermostat Wiring Guide - Reliant

Thermostat Wiring GuideThermostat Wiring Guide | 2 Wiring GuideThermostatThere are no standards for HVAC control Wiring . These diagrams depict some commonly used and frequently installed configurations but may not match your HVAC system. Consult a professional installer for advanced installations, or contact us at for connecTions showing c wire connecTionRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 2-wire heaT-only conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 3-wire heaT-only conTrol wires plus c wireR wire heat powerW wire heatR wire heat powerW wire heatG wire fanThermostat Wiring Guide | 3 RHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 4-wire heaT/cool-conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 5-wire heaT/cool-conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 6-wire mulTi-sTage heaT anD mulTi-sTage cool conTrol wires plus c wireW wire heatY wire cooling compressorR (or)

There are no standards for HVAC control wiring. These diagrams depict some commonly used and frequently installed configurations but may not match your HVAC system. Consult a professional installer for advanced installations, or contact us at 1.844.295.5556 for help. RH RC Z W2 W C Y Y2 G OB DefaulT connecTions showing c wire connecTion RH RC Z ...

Tags:

  Standards, Reliant

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Thermostat Wiring Guide - Reliant

1 Thermostat Wiring GuideThermostat Wiring Guide | 2 Wiring GuideThermostatThere are no standards for HVAC control Wiring . These diagrams depict some commonly used and frequently installed configurations but may not match your HVAC system. Consult a professional installer for advanced installations, or contact us at for connecTions showing c wire connecTionRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 2-wire heaT-only conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 3-wire heaT-only conTrol wires plus c wireR wire heat powerW wire heatR wire heat powerW wire heatG wire fanThermostat Wiring Guide | 3 RHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 4-wire heaT/cool-conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 5-wire heaT/cool-conTrol wires plus c wireRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 6-wire mulTi-sTage heaT anD mulTi-sTage cool conTrol wires plus c wireW wire heatY wire cooling compressorR (or)

2 RH wire powerG wire fanW wire heatY wire cooling compressorRemove jumper below W connectorRH wire powerRC wire powerG wire fanW wire heatW2 wire heatY wire cooling compressorY2 wire cooling compressorRH (or) R wire powerG wire fanThermostatThermostat Wiring Guide | 4 ThermostatRHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 4-wire heaT pump wiThouT auxiliary heaT conTrol wires plus c wire (alTernaTe)RHRCZW2 WCYY2 GOBD iagram of conTrol wire connecTions for 7-wire mulTi-sTage heaT pump wiTh mulTi-sTage auxiliary heaT conTrol wires plus c wireO wire (or) B wire changeover valve NOTE: If both O and B are present connect ONLY the O wire compressorR wire powerG wire fanO wire (or) B wire changeover valve NOTE: If both O and B are present connect ONLY the O wire auxiliary heatAux2 wire auxiliary heatY wire compressorY2 wire compressorR wire powerG wire fa