Transcription of Thru-Door Voltage Indicator - Graceport
1 ???????Redundant Circuitry / Long Life LED's40-750 VAC / 30-1000 VDC / 35-600 VAC 1 Potted Construction with 6' LeadsPhase Insensitive30mm Pushbutton or Pilot HoleHigh Surge ImmunityUL Listed, Type 4X, 12, 13?????Circuit Breaker Disconnects - No Visible BladesHigh Energy Panels (NFPA 70E Category 3 or 4 Frequently Accessed PanelsMechanical LOTO: Indicating Zero EnergyPanels with Multiple Power SourcesVoltage Indicatorwith Solid-on LEDs or Flashing LEDsThru-Door Voltage IndicatorFlashing and Non-FlashingProduct Data SheetCatalog NumbersR-3W / R-3W-SR(1)(3)Must be purchased as an assembly for UL ListingSee R-3W2 datasheet for specifications and UL information(2)For the R-3W-SR, the LED appearance for differing voltages as follows: 32-159V(FLASH).)
2 160-329V(SHIMMER); 330V+(SOLID)).SafeSidethru-door Voltage indicators provide electricalsafety information while the panel doors are safely one-size-fits-all solution detects 3-phase AC or DCvoltage from 40-750 VAC/30-1000 VDC. The encapsulatedconstruction and redundant circuit design means ruggedreliability. SafeSideproducts are available with flashingLEDs (R-3W) and non-flashing LEDs (R-3W-SR).Keeping personnel away from live Voltage is foundational toelectrical safety. Electrical safety demands a precise answerto the question 'Is Voltage present?
3 '. Thru-Door voltageindicators provide visibility of Voltage from outside theenclosure without exposing personnel to performing mechanical LOTO must isolateelectrical energy. An externally-mounted Voltage detectorprovides a means to check Voltage inside an electricalpanel. Without a Voltage Indicator , a mechanic performingmechanical LOTO would be required to work in tandem withan electrician using a voltmeter to physically verify voltageinside an electrical panel. In this case, the electrician isexposed to Voltage . With Thru-Door Voltage detectors, themechanic can verify zero electrical energy without anyexposure to is the common denominator in an electrical accidentor an arc flash; no Voltage means no accident, no arc performing electrical LOTO with a Thru-Door voltagedetector installed, the electrician can pre-check the internalvoltage state without opening the enclosure.
4 Next, theelectrician should replicate a zero Voltage reading with hisvoltmeter as per NFPA 70e (5). This low-cost,redundant Voltage -verification task reduces arc flash riskand increases electrical safety for workers. Safer Lock-Out Tag-Out (LOTO)More Productivity in Mechanical LOTOR educed Voltage Exposure and Arc Flash RiskR-3W-SR2 Non-FlashingR-3W-SR-KB1 Flush Mount Assembly with Bezel and R-3W-SR (UL)R-3W-SR-LAdhesive-Backed Warning Label(slips over installed R-3W-SR)R-3W23 Hazardous Location Flashing Voltage Indicator (Suitable foruse in Class 1, Division 2 (Zone 2), Groups A, B, C, D hazardousLocation, or Non-Hazardous Locations Only)R-3W2-KB1 Flush Mount Assembly with Bezel and R-3W2 (UL)R-3W-LAdhesive-Backed Warning Label(slips over installed R-3W2)
5 Three Phase 40-750 VAC/30-1000 VDC UL-Listed VoltageIndicator for Type 4X/12/13 for 30mm MountingLISTEDL CUSUL TYPE 4 XIND. CONT. File: E256847 RoHSR-3 WFlashingR-3W-KB1 Flush Mount Assembly with Bezel and R-3W (UL)R-3W-LAdhesive-Backed Warning Label(slips over installed R-3W)5001 Tremont AvenueDavenport, IA 52807(800) 280-9517 Fax: (563) 2014 Grace Engineered Products, :R-3W/R-3W-SR:08/2014 LIT-DS-R3 WSafeSideis a Trademark of Grace Engineered Products, Inc. FEATURES:APPLICATIONS:R-3W-KB-LAdhesive- Backed Warning Label(slips over installed R-3W-KB)R-3W-KB-LAdhesive-Backed Warning Label(slips over installed R-3W-SR-KB)R-3W-KB-LAdhesive-Backed Warning Label(slips over installed R-3W2-KB)Warning:Verify an electrical conductor has been de-energized using an adequately ratedvoltage detector before working on it.
6 Follow appropriate Energy Control (Lockout/Tagout)procedures as per OSHA Subpart S; the current edition of NFPA 70E; and the currentedition of CSA Single or 3-Phase: 40-750 VOperates up to 400 Hz30 to 1000 VDC750 VAC/1000 VDC - Surge 4300V for Watts @ 750 VAC (Approximately)Operate: -20 C to +55 C, Storage: -45 C to+85 C-PhaseOPERATIONAL RANGE:DC OR STORED ENERGY:MAXIMUM Voltage :POWER CONSUMPTION:TEMPERATURES:FAILURE CURRENT:FUSING:50/60 HzMaximum single component failure fault currentis @ 750 3 Follow all Local, State, and national ElectricalCodes when installing this protection of the supply leads maybe necessary.
7 The installation of overcurrentprotection shall be in accordance with therequirements in the NEC (NFPA 70) or endproduct standard(s) when used in the IndicatorTYPICAL CONFIGURATION* [ ]CUSTOMER PANELO-RING SEAL30mm HEX DIA. 4G6G [ ] [ ]POWERVACVDCL1L2L3 GND----++++ DIA.[ ] [ ] -0+.012[ -0+.03] +[ ]3+UP TO 1 ANTI-ROTATIONLOCATIONSWire: 18 AWG,Style 1452,THREE PHASE DELTA, 3W + GNDFUSEDSAFETYSWITCHORBREAKERREDYELBLUGR NL1 MAINFEEDGROUNDORISOLATEDL2L33-PHASE LINE-TO-LINE<2930120240480600750 FLASHES/SEC (TYPICAL) OR STORED ENERGY (VDC)<2730481103006001000 FLASHES/SEC (TYPICAL) FLASH RATES for the R-3W only (L1,L2,L3,GND)Accessories:WARNING!
8 Read instructionsbefore installingENGINEEREDPRODUCTS, IF FLASHINGSAFETY PROCEDURES STILL BEFORE Indicator Alert LabelThis adhesive-back label fits over an installed power warning language differs for flashing and non-flashing ! Bezel-mount Installation for Voltage Indicator !Create a near-flush look by purchasing your Voltage Indicatorwith our new !R-3W-KBR-3W-SR-KBPart NumberDescriptionFlashing Voltage Indicator with BezelNon-Flashing Voltage Indicator with BezelDimensions of the Bezel - Diameter: Outside cabinet depth: .20 Inside cabinet depth: R-3W-LR-3W-SR-LPart NumberDescriptionLabel for Flashing and Class 1 Div 2 Voltage IndicatorLabel for Non-Flashing Voltage IndicatorLabel dimensions are 3"W x " Part #: R-3W-NPT125A 30mm to 1 NPT conduit adapter.
9 Thisassembly fits into a standard conduit LB formounting on the outside of an #: R-3W-DR-C6 Use this door mount accessory for additional Voltage a 30mm adapter and 6' of NW10 flexible conduit.(Allow " depth into panel). R-3W2-KBClass 1 Div 2 Voltage Indicator with Bezel*Corresponding label available for bezel-mount : When mounting the Bezel (part numbers with -KB), thediameter of the cut-out is as follows: inches ( ).R-3W-KB-LLabel for all Bezel Units