Example: tourism industry

TM 11-5895-1838-13&P - Specialized electronics …

TM 11- 5895 - 1838 -13&P. TECHNICAL MANUAL. OPERATOR'S, UNIT, AND DIRECT SUPPORT. MAINTENANCE MANUAL. (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST). FOR. REPLACEMENT FREQUENCY. MODULATED ORDERWIRE (RFMOW). (AN/GSC-69(V)1, NSN: 5895 -01-522-2119 (85 Terminal), NSN: 5975-01-529-3943 (Rack Adapter Kit for 85 Terminal), AN/GSC-69(V)2, NSN: 5895 -01-522-2117 (93 Terminal)). EIC: N/A. VERIFIED DRAFT. Rev. 01 March 20, 2007. Distribution authorized to the Department of Defense and DOD contractors only for official use or for administrative or operational purposes. This determination was made on 15 MAY 2004 Other requests for this document will be referred to Commander, US Army Communications- electronics Command and Fort Monmouth, ATTN: AMSEL-LC-COM-T- SLEP, Fort Monmouth, New Jersey 07703-5007.

Replacement Frequency Modulated Orderwire TM 11-5895-1838-13&P Safety Summary B REV 01 SAFETY SUMMARY Warnings, Cautions, and Notes which appear in this manual are defined as follows:

Tags:

  Notes, Electronic, Tm 11 5895 1838 13 amp p, 5895, 1838

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TM 11-5895-1838-13&P - Specialized electronics …

1 TM 11- 5895 - 1838 -13&P. TECHNICAL MANUAL. OPERATOR'S, UNIT, AND DIRECT SUPPORT. MAINTENANCE MANUAL. (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST). FOR. REPLACEMENT FREQUENCY. MODULATED ORDERWIRE (RFMOW). (AN/GSC-69(V)1, NSN: 5895 -01-522-2119 (85 Terminal), NSN: 5975-01-529-3943 (Rack Adapter Kit for 85 Terminal), AN/GSC-69(V)2, NSN: 5895 -01-522-2117 (93 Terminal)). EIC: N/A. VERIFIED DRAFT. Rev. 01 March 20, 2007. Distribution authorized to the Department of Defense and DOD contractors only for official use or for administrative or operational purposes. This determination was made on 15 MAY 2004 Other requests for this document will be referred to Commander, US Army Communications- electronics Command and Fort Monmouth, ATTN: AMSEL-LC-COM-T- SLEP, Fort Monmouth, New Jersey 07703-5007.

2 HANDLING AND DESTRUCTION NOTICE Comply with distribution statement and destroy by any method that will prevent disclosure of contents or reconstruction of the document. This page left blank intentionally. TM 11- 5895 - 1838 -13&P Replacement Frequency Safety Summary Modulated Orderwire SAFETY STEPS TO FOLLOW IF SOMEONE. 5 IS THE VICTIM OF ELECTRICAL SHOCK. 1 DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL. 2 IF POSSIBLE, TURN OFF THE ELECTRICAL POWER. 3 IF YOU CANNOT TURN OFF THE ELECTRICAL. POWER, PULL, PUSH, OR LIFT THE PERSON TO. SAFETY USING A DRY WOODEN POLE OR A DRY. ROPE OR SOME OTHER INSULATING MATERIAL. 4 SEND FOR HELP AS SOON AS POSSIBLE. 5 AFTER THE INJURED PERSON IS FREE OF. CONTACT WITH THE SOURCE OF ELECTRICAL. SHOCK, MOVE THE PERSON A SHORT DISTANCE.

3 AWAY AND IMMEDIATELY START ARTIFICIAL. RESUSCITATION. A REV 01. Replacement Frequency TM 11- 5895 - 1838 -13&P. Modulated Orderwire Safety Summary SAFETY SUMMARY. Warnings, Cautions, and notes which appear in this manual are defined as follows: WARNING. An operating or maintenance procedure, practice, condition, statement, etc., which, if not strictly observed, could result in injury to or death of personnel. CAUTION. An operating or maintenance procedure, practice, condition, statement, etc., which, if not strictly observed, could result in damage to, or destruction of, equipment or loss of mission effectiveness or long term health hazards to personnel. NOTE. An essential operating or maintenance procedure, condition, or statement which must be highlighted.

4 B REV 01. TM 11- 5895 - 1838 -13&P Replacement Frequency Safety Summary Modulated Orderwire WARNING. Proper grounding is an important safety feature, and must be a primary consideration in all electrical and electronic equipment installations. Ensure that all grounding connections are secure and that all grounding cables are kept out of vehicle and personnel paths. WARNING. Use extreme care when working around electrical equipment to avoid the possibility of severe or fatal electrical shock. Remove all jewelry ( rings, necklaces, etc.) before working with the RFMOW. WARNING. Ensure that all power connections are properly insulated, clean, and mechanically secure to prevent personnel injury when the RFMOW is powered up and operated. When the RFMOW power cables are installed, carefully inspect all connectors and wiring for worn or broken parts.

5 Make any necessary repairs before powering up the RFMOW. If any cable or connector damage is discovered while the RFMOW is operating, the RFMOW should be powered down and the damage repaired immediately. WARNING. Even with covers removed, lethal voltages may still be present inside the RFMOW. Failure to exercise caution could result in fatal or serious injury to personnel. WARNING. High voltage, 120 VAC, is present in this equipment. Use extreme caution and ensure that at least two people are present while performing inspection, test, and maintenance procedures. Failure to comply may result in fatal or serious injury to personnel. WARNING. Ensure that power is removed during the performance of equipment replacement and cleaning procedures.

6 Do not open equipment enclosures when cleaning. Use of damp cleaning materials can cause shock, resulting in fatal or serious injury to personnel. WARNING. Hazardous voltages are present. Use care when measuring for voltage. Failure to do so can result in fatal or serious injury to personnel. C REV 01. Replacement Frequency TM 11- 5895 - 1838 -13&P. Modulated Orderwire Safety Summary WARNING. RFMOW weight in the crate is approximately 180 lbs. ( kg). A forklift or equivalent is required to move the crate. Individual weights of items in the crate are listed in section (not including shipping materials). Two persons are required to install the RFMOW Rack, which is approximately 74 lbs. ( kg). Failure to comply may result in fatal or serious injury to personnel, and/or damage to the equipment.

7 CAUTION. This equipment contains static-sensitive devices. Always follow ESD handling procedures when working on this equipment. D REV 01. TM 11- 5895 - 1838 -13&P Replacement Frequency Foreword Modulated Orderwire FOREWORD. PURPOSE: This manual provides operation and maintenance information for the Replacement Frequency Modulated Orderwire (RFMOW). HOW TO USE THIS MANUAL: Step-by-step procedures with illustrations give all the necessary information to setup, operate, and maintain this equipment at unit levels only. Do not attempt any procedure before first becoming familiar with the entire procedure. For general information, use the table of contents in the front of this book to locate chapters and sections containing this information.

8 SCOPE: This technical manual covers procedures and supporting information required for operating and maintaining the RFMOW. Coverage includes operating, maintenance instructions, troubleshooting, test, and repair data. The material presented in this manual is written for experienced operator and maintenance personnel responsible for the RFMOW. Standard shop practices used during maintenance are not described. ARRANGEMENT: This manual is arranged into five chapters and five appendixes. A brief description of each chapter follows: Chapter 1 Equipment Description and Data Provides general information and brief description of the RFMOW including system description, technical characteristics, equipment supplied, and equipment required but not supplied.

9 Chapter 2 Operating Instructions Provides identification of all operating controls, indicators, connectors, and operating procedures. Operating procedures for power up, system initialization, preliminary checkout, operation and power down are included. Chapter 3 Troubleshooting Provides information on troubleshooting the RFMOW, as well as pin out diagrams and schematics. Chapter 4 Maintenance Instructions - Contains maintenance concept, preventive and corrective maintenance procedures, and removal and replacement procedures. Chapter 5 Repair Parts and Special Tools List - Provides part lists for the RFMOW. Appendix A Reference Publications Provides information on reference documentation related to the RFMOW. Appendix B Maintenance Allocation Charts Provides the Maintenance Allocation Chart (MAC).

10 For the RFMOW 41700-8593. Appendix C Components of End Item and Basic Issue Items Lists items required to enable safe and efficient operation of the RFMOW. Appendix D Expendable/Durable Items List Lists items needed to operate and maintain the RFMOW. Appendix E Manual Equipment Configuration Procedures Lists items needed to be manually configured. Appendix F Power Balance/Alignment Procedure Provides procedure for aligning the terminal. Appendix G Software Operation Provides procedures to power up and to conduct normal network operations. Appendix H Glossary Lists acronyms and abbreviations used in this manual. E REV 01. Replacement Frequency TM 11- 5895 - 1838 -13&P. Modulated Orderwire Safety Summary DEFINITIONS: The word "shall" is used in this manual to express a provision that is binding.


Related search queries