Example: barber

TM 3-4240-313-10 OPERATOR'S MANUAL - …

TM 3-4240-313-10 OPERATOR'S MANUALSIMPLIFIED COLLECTIVEPROTECTION EQUIPMENT: M20A1(NSN 4240-01-330-7806)WARNING - This document contains export-controlled technical data whose export isrestricted by the Army Export Control Act (Title 22, US C, Sec2751 et deq)or ExecutiveOrder 12470 Violation of these export laws are subject to severe criminal STATEMENT C Distribution authorized to Government agenciesand their contractors to protect technical or operational information from automaticdissemination under the International Exchange Program or by other means. Thisdetermination was made on 13 Nov 1986. Other requests for this document will bereferred to Technical Director, U S Army Edgewood Research, Development andEngineering Center ATTN SCBRD EN-V, Aberdeen Proving Ground MD NOTICE - Destroy by any method that will prevent \ disclosure ofcontents or reconstruction of the , DEPARTMENT OF THE ARMY17 NOVEMBER 1995TM 3-4240-313-10 WARNINGTOXIC HAZARDD econtaminate all contaminated equipment and personnel before erecting Simplified CollectiveProtection Equipment (SCPE).

TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document contains export-controlled technical data whose export is

Tags:

  Manual, Operator, 4402, 3 4240 313 10 operator s manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TM 3-4240-313-10 OPERATOR'S MANUAL - …

1 TM 3-4240-313-10 OPERATOR'S MANUALSIMPLIFIED COLLECTIVEPROTECTION EQUIPMENT: M20A1(NSN 4240-01-330-7806)WARNING - This document contains export-controlled technical data whose export isrestricted by the Army Export Control Act (Title 22, US C, Sec2751 et deq)or ExecutiveOrder 12470 Violation of these export laws are subject to severe criminal STATEMENT C Distribution authorized to Government agenciesand their contractors to protect technical or operational information from automaticdissemination under the International Exchange Program or by other means. Thisdetermination was made on 13 Nov 1986. Other requests for this document will bereferred to Technical Director, U S Army Edgewood Research, Development andEngineering Center ATTN SCBRD EN-V, Aberdeen Proving Ground MD NOTICE - Destroy by any method that will prevent \ disclosure ofcontents or reconstruction of the , DEPARTMENT OF THE ARMY17 NOVEMBER 1995TM 3-4240-313-10 WARNINGTOXIC HAZARDD econtaminate all contaminated equipment and personnel before erecting Simplified CollectiveProtection Equipment (SCPE).

2 When erecting SCPE in a toxic environment, protective mask and clothing must be worn by allpersonnel until SCPE is deployed and operational. The level of protective clothing will bedetermined by the unit SCPE is deployed in a toxic environment, it may take up to 1-1/2 hours from time blower isturned on to purge liner of toxic vapors. Personnel who must enter SCPE during 1-1/2 hourpurge time shall wear clean, uncontaminated protective clothing. Failure to do so could result inprolonged purge time and recontamination of not locate blower near an area where exhaust gasses are generated because filter will notremove carbon HAZARDThe blower operating noise may be hazardous to operator hearing. Hearing protection must beworn when remaining within 4 feet of blower in HAZARDT hree major components of SCPE weigh approximately 100 pounds each.

3 Lifting and/or carryingcan be accomplished by no fewer than two lifting of PE top when erecting may cause back strain to personnel. To avoid backstrain follow, proper lifting edges of the filter canister can cause injury to personnel. Use care when connecting ordisconnecting air ducts to hands clear of leg hinges when erecting or striking protective entrance (PE).FIRE HAZARDKeep flame, spark and heat clear of VOLTAGEHigh voltage exists in motor blower and recirculation filter. To prevent electrical shock ensuremotor blower power switch is in off (down) position before connecting or disconnecting power cable before performing any maintenance AIDFor first aid information, refer to FM (b blank)TM 3-4240-313-10 Technical ManualHEADQUARTERSNo. 34240-413-10 Department of the ArmyWashington, , 17 November 1995 OPERATOR'S MANUALFORSIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1(NSN 4240-01-330-7806)REPORTING ERRORS AND RECOMMENDING IMPROVEMENTSYou can help improve this MANUAL .

4 If you find any mistake or if you know of a way toimprove the procedures, please let us know. Mail your letter or DA Form 2028(Recommended Changes to Publications and Blank Form) direct to: Technical Director, Army Edgewood Research, Development and Engineering Center, ATTN: SCBRD-ENL-V, Aberdeen Proving Ground, MD 21010-5423. A reply will be furnished to document contains export-controlled technical data whose export is restricted by the ArmyExport Control Ac (Title 22, , Sec 2751 et seq) or Executive Order 12470. Violation of theseexport laws are subject to severe criminal STATEMENT C: Distribution authorized to Government agencies and theircontractors to protect technical or operational information from automatic dissemination underthe International Exchange Program or by other means. This determination was made on 13 Nov86.

5 Other requests for this document will be referred to: Technical Director, ArmyEdgewood Research, Development and Engineering Center, ATTN: SCBRD-ENL-V, AberdeenProving Ground, MD NOTICE Destroy by any method that will prevent disclosure of contents orreconstruction of the OF CONTENTSPageHOW TO USE THIS MANUAL ..ivCHAPTER 1 INTRODUCTION ..1-1 Section IGeneral Information ..1-1 Section IIEquipment Description and Data ..1-3 Section IIIP rinciples of 3-4240-313-10 TABLE OF CONTENTS (CONT)PageCHAPTER 2 OPERATING INSTRUCTIONS ..2-1 Section IDescription and Use of Operators Controls and Indicators ..2-2 Section IIPreventive Maintenance Checks and Services (PMCS) ..2-5 Section IIIO peration Under Usual Conditions ..2-22 Section IVOperation Under Unusual Conditions ..2-63 CHAPTER 3 MAINTENANCE INSTRUCTIONS ..3-1 Section ILubrication Instructions.

6 3-1 Section IITroubleshooting IIIM aintenance Procedures ..3-5 APPENDIX AREFERENCES ..A-1 APPENDIX BCOMPONENTS OF END ITEM AND BASIC ISSUE ITEMS UST ..B-1 APPENDIX CADDITIONAL AUTHORIZATION UST (AAL)..C-1 APPENDIX DEXPENDABLE AND DURABLE ITEMS (iii blank)TM 3-4240-313-10M20A1 Simplified Collective Protection Equipment1-0TM 3-4240-313-10 CHAPTER 1 INTRODUCTIONS ection I. GENERAL INFORMATION1-1. of MANUAL . This is the OPERATOR'S MANUAL for use with the M20A1 Simplified Collective ProtectionEquipment (SCPE). Name and Model Number. Simplified Collective Protection Equipment: of Equipment. The SCPE provides a clean-air shelter for use against chemical and biological warfareagents and radioactive particles. The SCPE is an inflatable shelter which allows personnel to perform duties withoutwearing individual protective Limitations.

7 The M20A1 SCPE should be deployed in a structurally sound building. It MUST NOT bedeployed outside, where it would be subject to wind, rain, solar heat loading, or direct contact with liquid agents. TheSCPE does not provide:(1)Environmental control equipment (heating and cooling); however, interfaces are provided.(2)A portable source of electrical power (electrical generator).(3)NBC detection devices.(4)Protection from nuclear radiation, however, the SCPE does provide protection against radioactiveparticles.(5)Protection from carbon monoxide exhaust MAINTENANCE FORMS AND of the Army forms and procedures used for equipment maintenance will be those prescribed by DAPAM 738-750, The Army Maintenance Management System (TAMMS).1-3. DESTRUCTION OF ARMY MATERIEL TO PREVENT ENEMY SCPE destruction procedures to prevent enemy use, refer to TM 43)0002-31 Destruction of ChemicalWeapons and Defense Equipment to Prevent Enemy REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATION (EIR).

8 If your SCPE needs improvement, let us know. Send us an EIR You, the user, are the only one who can tell uswhat you don't like about your equipment. Let us know why you don't like the design or performance. Put it on aStandard Form 368, Quality Deficiency Report. Mail it to us at Armament and Chemical Acquisition and LogisticsActivity, ATTN: AMSTA-AR-QAW-A, Rock Island, IL 61299-6000. We will send you a 3-4240-313-101-5. CORROSION PREVENTION AND CONTROL (CPC). Prevention and Control (CPC) of Army material is a continuing concern. It is important that anycorrosion problems with this item be reported so that the problem can be corrected and improvements can be made toprevent the problem in future corrosion is typically associated with rusting of metals, it can also include deterioration of other materialssuch as rubber and plastic.

9 Unusual cracking, softening, swelling, or breaking of these materials may be a a corrosion problem is identified, it can be reported using Standard Form 368. Use of key words such as"corrosion," "rust," "deterioration," or "cracking" will assure that the information is identified as a CPC Standard Form 368 should be submitted Army Armament and Chemical Acquisition and Logistics ActivityATTN: AMSTA-AR-QAW-A/ Customer Feedback CenterRock Island, Illinois 61299-60001-6. NOMENCLATURE CROSS-REFERENCE NameOfficial NomenclatureGageDifferential Pressure GageM20Al SCPES implified Collective Protection Equipment: M20Al1-7. LIST OF Thermal UnitcfmCubic feet per minutecmCentimeterDOTD epartment of TransportationECUE nvironmental Control UnitHSFCH ermetically Sealed Filter CanisterHzHertziwgInches of water gagekgKilogramkwKilowattmMeterNANot ApplicableNBCN uclear, Biological, ChemicalPEPressurized Protective EntranceVACVolt Alternating CurrentVDCVolt Directing Current1-2TM 3-4240-313-10 Section II.

10 EQUIPMENT DESCRIPTION1-8 EQUIPMENT CHARACTERISTICS, CAPABIUTIES, AND Characteristics.(1)Transported by truck.(2)Operates from 110/220 VAC, 50/60 Hz power.(3)Easily maintained.(4)System can be deployed using two and Features.(1)Includes liquid agent resistant liner.(2)Provides a recirculation filter which filters and cleans air inside the shelter.(3)Has a PE that allows personnel to move from a contaminated area into the protective shelter without introducing contaminants.(4)Can be operated without HSFC when system is used for training.(5)Accessory package contains material and repair tape for restoring damaged liners, hoses, and PE tousable condition.(6)Provides adapters to interface with environmental control unit (ECU). Two types of MIL-A-52767 ECU can be interfaced:Type 1, Size C, 18,000 BTU compact vertical air conditioner orType 2, Size C, 18,000 BTU compact horizontal air conditioner.


Related search queries