FlameOff - intumescent coatings provide passive fire protection for design professionalsFlameOFF Coatings, Inc. manufactures intumescent coatings that are IBC/NFPA Code Compliant for ASTM E-119 fire endurance ratings that require 1 or 2 hour fire protection while allowing a decorative look to be intumescent coating advantages: Water-based intumescent coating with low VOC; Can be finished with a wide selection of topcoat colors; Provides a smooth architectural finish; and Provides up to 2-hour fire resistance ratings in accordance withUL 263 (ASTM E119), CAN / ULC-S101 and ISO - intumescent coatings provide the applicator an easier installation of the intumescent coatingFlameOFF FCI intumescent coatings provide the installer an easier a

FlameOff Fire Barrier Paint TM Submittal Data Sheet Structural Steel Application Equipment Guidelines General equipment guidelines are given below, and may need to be modified depending on

Tags:

  Guidelines, Barriers, Fire, Paint, Flameoff fire barrier paint, Flameoff

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TM Submittal Data Sheet FlameOff Fire Barrier Paint ...

1 FlameOff - intumescent coatings provide passive fire protection for design professionalsFlameOFF Coatings, Inc. manufactures intumescent coatings that are IBC/NFPA Code Compliant for ASTM E-119 fire endurance ratings that require 1 or 2 hour fire protection while allowing a decorative look to be intumescent coating advantages: Water-based intumescent coating with low VOC; Can be finished with a wide selection of topcoat colors; Provides a smooth architectural finish; and Provides up to 2-hour fire resistance ratings in accordance withUL 263 (ASTM E119), CAN / ULC-S101 and ISO - intumescent coatings provide the applicator an easier installation of the intumescent coatingFlameOFF FCI intumescent coatings provide the installer an easier application of the intumescent coating and offer design professionals many benefits.

2 Passive fire protection can be achieved on many different substrates. Our intumescent coatings are thin-filmed and are not like the traditional bulky and chalky coatings. This allows the design professionals to use intumescent coatings in areas that traditional fire proofing methods were once coating benefitsFlameOFF Coatings, Inc. has engineered all our intumescent coatings to offer a application process that is less complicated than other intumescent coatings on the market. FlameOff Coatings, Inc.

3 Offers an in-house/web-based certification program to insure that each and every fire proofing applicator has the product knowledge they need to install a fire protective intumescent coating that meets our requirements. Intumescent coatings that offer integrity in application and designFlameOFF Coatings, Inc. has a team of experienced intumescent coating professionals. We can assist in installation, technical, or the design phase of the project. FlameOff Coatings, Inc. offers on-site support during the intumescent coating application; we also offer design support during the project design stage.

4 FlameOff intumescent coatings that are tested to ASTM E119 - full scaleOur intumescent coatings are tested to full scale. The ASTM E-119 test method requires full scale testing to be achieved in order to classify a product as ASTM E-119 rated. IBC/NFPA Code require a product to be in a Listed directory by an IAS accredited lab that is certified to perfom ASTM E-119 fire testing for full scale structural members. Phone: (888) 816-7468 Email: Web: Coatings, Inc. owns and certifies all data in this document.

5 This document may not be altered by anyone other than FlameOff Coatings, data and suggested formulations in this bulletin are based on information believed to be reliable and are offered solely for evaluation, investigation and verification of numerous factors affecting results. FlameOff Coatings, Inc. products are sold with the understanding the purchasers will make their own tests to determine the suitability of these products for the particular use. We assume no liability or responsibility for any damage to person or property resulting from or incident to the use of our products.

6 Statements concerning the use of FlameOff Coatings, Inc. products are not be construed as recommending the infringement of any patent, and no liability for infringement arising out of any such use is Coatings, Inc. fire Barrier Paint ASTM - E-119 tested 1 hour ratings 2 hour ratingsTested to ASTM E-119 fire endurance requirements to meet the full scale requirement of IBC/NFPA building fire Barrier PaintTMSubmittal and Guide Specification Structural SteelFlameOff fire Barrier PaintTMSubmittal and Guide Specification Structural SteelFlameOFF is a water-based intumescent coating designed for fire protection of structural steel for interior applications requiring ASTM E -119 testing for full

7 Scale/load bearing FCI is a decorative thin film intumescent coating that consists of a vinyl acetate resin. It can be top coated to provide the desired color match recommended use for this product is fireproofing of interior steel beams, columns, tube steel, and Features: Designs for many types of steel section; Decorative finish - provides a hard, durable, architecturalfinish. Compatible topcoats available in a wide range ofcolors; Thin film coating - offers an economical solution toalternative fireproofing; VOC compliant; Easy repair - If damaged, product can be patched easily.

8 Third party listing Finish Off White smooth finishWet Film Thickness mils (1143 microns)Dry Film Thickness mils (762 microns)Solids Content By Volume 69%Theoretical Coverage Rate1075 ft2 at 1 mil (1002 m / at 25 microns) 36 ft2 at 30 mils ( 2 m / at 750 microns)Calculating Dry Film Thickness In order to accurately calculate the dry film thickness the following calculation should be used: WFT=(DFT/Volume Solids) X 100 Limitations Product must be top coated if there are environmental exposure requirements.

9 Refer to FlameOff Coatings, Inc. technical Preparation All surfaces must be primed and must be clean, dry, and free of oil, grease, loose mil scale, dirt, dust or other materials that would impair the bonding of FlameOff to the Topcoats For interior conditioned space, topcoats are optional. For general purpose requirements,Contact Technical Services at FlameOff Coatings, Inc to obtain a list of approved/tested topcoats.** Intumescent coating must be applied to the required DFT and cured before a topcoat is /Certification / Listing Wide Flange Columns: B1077-1 Tube Columns: B1077 Pipe Columns: B1077 Beams: GL-N609 Beams (Protected Deck): GL-D784 Beams (Unprotected Deck): GL-D935 Maintenance If coating becomes damaged, rebuild therequired thickness by spray or brush.

10 When dry, smooth and finished. Topcoat may be applied. The repair area must follow all surface preparation requirements before reapplying the coating. The coating must be built back to the original Coatings, Inc fire Barrier Paint 1 Hour ratings 2 Hour ratingsTested to ASTM E-119 fire Endurance requirements to meet the Full Scale requirement of IBC/NFPA Building Codes.**NOTE: This specification manual follows the standard specification requirements for Division 07 - 8140 - Intumescent fireproofing.