Example: bachelor of science

TP, TPD, TPE, TPED - Recondi Brasov

GRUNDFOS DATA BOOKLET. TP, TPD, TPE, TPED. In-line circulator pumps 50 Hz Contents Pump data TP Series 400 pumps Introduction 4 Technical data 25. TP, mains-operated pumps 4 Construction 25. TPE, speed-controlled pumps 4 Materials 25. Type key 5 Mechanical shaft seal 26. Codes for shaft seal 5 Connections 26. Features and benefits 26. Performance range Performance range, 2-pole, PN 6, 10, 16 6 TPE Series 1000 pumps Performance range, 4-pole, PN 6, 10, 16 7 Technical data 27. Performance range, 6-pole, PN 16 8 Construction 27. Performance range, 2-pole, PN 25 9 Applications 27.

TP, TPD, TPE, TPED 4 Pump data Introduction TP pumps are designed for applications such as • district heating systems • heating systems • air-conditioning systems • district cooling systems • water supply • industrial processes • industrial cooling.

Tags:

  Dept

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TP, TPD, TPE, TPED - Recondi Brasov

1 GRUNDFOS DATA BOOKLET. TP, TPD, TPE, TPED. In-line circulator pumps 50 Hz Contents Pump data TP Series 400 pumps Introduction 4 Technical data 25. TP, mains-operated pumps 4 Construction 25. TPE, speed-controlled pumps 4 Materials 25. Type key 5 Mechanical shaft seal 26. Codes for shaft seal 5 Connections 26. Features and benefits 26. Performance range Performance range, 2-pole, PN 6, 10, 16 6 TPE Series 1000 pumps Performance range, 4-pole, PN 6, 10, 16 7 Technical data 27. Performance range, 6-pole, PN 16 8 Construction 27. Performance range, 2-pole, PN 25 9 Applications 27.

2 Performance range, 4-pole, PN 25 10 TPE(D) pumps with extended performance range 28. Operating modes of twin-head pumps 28. Control options 28. Product range Product range, 2-pole, PN 6, 10, 16 11. Product range, 4-pole, PN 6, 10, 16 13 TPE Series 2000 pumps Product range, 6-pole, PN 16 15 Technical data 29. Product range, 2-pole, PN 25 15 Construction 29. Product range, 4-pole, PN 25 16 Applications 29. TPE(D) pumps with extended performance range 30. Operating modes of twin-head pumps 30. Operating conditions Control options 30. System and test pressures 17. Sound pressure level 17.

3 Ambient temperature 17 Communication Communication with TPE, TPED pumps 31. Pumped liquids Pumped liquids 18 Speed regulation of TPE pumps Liquid temperature 18 Affinity equations 32. List of pumped liquids 19. TP, TPE pumps in parallel TP Series 100 and 200 pumps Control of TP, TPE pumps connected in parallel 33. Technical data 21 Alternation/standby function of TPED pumps 33. Construction 21 TP, TPE pumps connected to Control MPC 33. Materials 21 TPE Series 2000 pumps connected to Control MPC. Mechanical shaft seal 22 Series 2000 34. Connections 22. Features and benefits 22.

4 Grundfos CUE. TP pumps connected to Grundfos CUE, external TP Series 300 pumps frequency converters 35. Technical data 23 Functions 35. Construction 23 External communication 35. Materials 23. Mechanical shaft seal 23. Connections 24 Motor data Features and benefits 24 Motors 36. Motor protection 37. Electrical data, mains-operated motors 38. Electrical data, speed-controlled motors 40. 2. Contents Installation Mechanical installation 41. Electrical installation 46. Flanges for TP pumps Flange dimensions 48. Curve charts How to read the curve charts 49. Curve conditions 50.

5 Technical data/performance curves TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16 52. TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16 74. TP, TPD, TPE, TPED, 6-pole, PN 16 100. TP, 2-pole, PN 25 104. TP, 4-pole, PN 25 106. Weights and shipping volume TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16 120. TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16 121. TP, TPD, 6-pole, PN 6, 10, 16 123. TP, 2-pole, PN 25 123. TP, 4-pole, PN 25 123. Accessories Unions and valves 125. Counter flanges 126. Base plates 129. Blanking flanges 131. Insulating kits 135. Sensors 136. Potentiometer 137. R100 137. CIU communication interface units 137.

6 CIM communication interface modules 138. EMC filter 138. Minimum inlet pressure - NPSH. TP, TPD, 2-pole, PN 6, 10, 16 140. TP, TPD, 4-pole, PN 6, 10, 16 141. TP, TPD, 6-pole, PN 16 141. TP Series 400, 2-pole, PN 25 141. TP Series 400, 4-pole, PN 25 142. Further product documentation WebCAPS 143. WinCAPS 144. 3. Pump data TP, TPD, TPE, TPED. Introduction TPE Series 1000 pumps The difference between the TP and the TPE Series TP pumps are designed for applications such as 1000 pump range is the motor. The motors of TPE. district heating systems Series 1000 pumps have built-in frequency converter.

7 Heating systems Via an external signal (from a sensor or a controller), air-conditioning systems TPE Series 1000 pumps allow for any configuration and district cooling systems control method required: Constant pressure, water supply temperature or flow. industrial processes For further information, see page 27. industrial cooling. TPE Series 2000 pumps The pumps are available with either mains-operated The main differences between the TP and the TPE. motors (TP and TPD) or electronically speed-controlled Series 2000 pumps are the motor and the factory-fitted motors (TPE and TPED).

8 Differential-pressure sensor. The pumps are all single-stage, in-line centrifugal TPE Series 2000 pumps are factory-set to proportional- pumps with mechanical shaft seal. The pumps are of pressure control. the close-coupled type, pump and motor are The motors of TPE Series 2000 pumps have built-in separate units. Consequently, the pumps are less frequency converter for continuous adjustment of the sensitive to impurities in the pumped liquid than similar pressure to the flow rate. pumps of the canned rotor type. The TPE Series 2000 range is recognized as a preset TP, mains-operated pumps solution for quick and safe installation.

9 The TP range is divided into the following four groups For further information, see page 29. based on their construction: TP Series 100, 200, 300. and 400. Why select a TPE pump? A TPE pump with electronic speed control offers these TP Series 100 with union or flange connection obvious benefits: Rp 1 (DN 25) to Rp 1 1/4 (DN 32) and motor sizes from to kW. energy savings increased comfort For further information, see page 21. control and monitoring of pump performance TP Series 200 with flange connection communication with the pump. DN 32 to DN 100 and motor sizes from to kW.

10 ATEX-approved TP pumps For further information, see page 21. On request, Grundfos offers TP and TPD pumps with TP Series 300 with flange connection ATEX-approval. DN 32 to DN 200 and motor sizes from to 132 kW. All ATEX-approved TP pumps are in accordance with For further information, see page 23. Council directive 94/9/EC (Group II, category 3). If an ATEX-approved dry-running protection is TP Series 400 with flange connection installed, the pump can be upgraded to category 2G. Grundfos offers two TP Series 400 versions: High-efficiency motors 10 bar version with DN 250 flange and motor sizes TP pumps are fitted with high-efficiency motors.


Related search queries