Example: confidence

TQ 402 & TQ 412 / EA 402 / IQS 452 TQ 402 & TQ …

First draft Vibro-Meter SA / 265-062 / / E1 / 12TQ 402 & tq 412 / EA 402 / IQS 452 Proximity System : tq 402 & tq 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner]Non-contacting measurement system based on eddy current principle]Certified for use in potentially explosive atmospheres] tq 402 conforms to API 670 recommendations]5 m and 10 m systems]Temperature compensated system]Voltage or current output with protection against short circuitsFEATURESIQS 452TQ 402TQ 412]Measuring range:2 mm or 4 mm]Transducer temperature range:-40 C to +180 C]Sensitivity:4 mV/ m or 8 mV/ A/ m or A/ m]Frequency response:DC to 20 kHz (-3 dB)CHARACTERISTICSF irst draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E2 / 12 This proximity system allows contactless measurement of the relative displacement of moving machine elements.

F ir s t d r a f t Proximity System TQ 402 & TQ 412 / EA 402 / IQS 452 © Vibro-Meter SA / 265-062 / 06.06 / E 6 / 12 TQ 402 / TQ 412 Proximity Transducer

Tags:

  Tq 402, Tq 412

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TQ 402 & TQ 412 / EA 402 / IQS 452 TQ 402 & TQ …

1 First draft Vibro-Meter SA / 265-062 / / E1 / 12TQ 402 & tq 412 / EA 402 / IQS 452 Proximity System : tq 402 & tq 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner]Non-contacting measurement system based on eddy current principle]Certified for use in potentially explosive atmospheres] tq 402 conforms to API 670 recommendations]5 m and 10 m systems]Temperature compensated system]Voltage or current output with protection against short circuitsFEATURESIQS 452TQ 402TQ 412]Measuring range:2 mm or 4 mm]Transducer temperature range:-40 C to +180 C]Sensitivity:4 mV/ m or 8 mV/ A/ m or A/ m]Frequency response:DC to 20 kHz (-3 dB)CHARACTERISTICSF irst draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E2 / 12 This proximity system allows contactless measurement of the relative displacement of moving machine elements.

2 It is particularly suitable for measuring the relative vibration and axial position of rotating machine shafts, such as those found in steam, gas and hydraulic turbines, as well as in alternators, turbo-compressors and system is based around a tq 402 or tq 412 non-contacting transducer and its matching IQS 452 signal conditioner. Together, these form a calibrated proximity system in which each component is interchangeable. The system outputs a voltage or current proportional to the distance between the transducer tip and the target ( machine shaft).The active part of the transducer is a coil of wire that is moulded inside the tip of the device, which is made of Torlon (polyamide-imide). The transducer body is made of stainless steel. The target material must, in all cases, be transducer body is available with metric or English thread.

3 The tq 412 version is intended for reverse-mount applications. The tq 402 /412 has an integral coaxial cable, terminated with an AMP-type connector. Various cable lengths (integral and extension) may be ordered. The IQS 452 signal conditioner contains an HF modulator/demodulator that supplies a driving signal to the transducer. This generates the necessary electromagnetic field used to measure the gap. The conditioner circuitry is made of high-quality components and is mounted in an aluminium tq 402 /412 transducer can be matched with a single EA 402 extension cable. Optional junction boxes and housings offer mechanical protection of the integral and extension cable proximity system is powered by associated processor modules or a rack power Overall Proximity SystemOPERATIONS ensitivity Using IQS 452 Version 0XX:4 mV/ m (100 mV/mil) Using IQS 452 Version 1 A/ m ( A/mil) Using IQS 452 Version 2XX:8 mV/ m (200 mV/mil) Using IQS 452 Version 3 A/ m ( A/mil)Linear measuring range (typical) Using IQS 452 Version 2XX or IQS 452 Version 3 - mm, corresponding to V to V output using IQS 452 Version mA to mA output using IQS 452 Version 3XX Using IQS 452 Version 0XX or IQS 452 Version 1 - mm, corresponding V to V output using IQS 452 Version mA to mA output using IQS 452 Version 1 XXLinearity:See system performance curvesFrequency response.

4 DC to 20 kHz (-3 dB)Interchangeability of elements:All components in system are interchangeableFirst draft Vibro-Meter SA / 265-062 / / E3 / 12 Proximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 ENVIRONMENTALUse in explosive atmospheres EC type examination certificate:LCIE 02 ATEX 6086 X II 2 G (Zones 1, 2) EEx ib IIC T6 to T3 For specific parameters of the mode of protection concerned and special conditions for safe use, please refer to the EC type examination certificate that is available from Vibro-Meter SA on demand. CSA standard:Certificate 1514309 (LR 62075-5),Class I, Divisions 1 and 2, Groups A, B, C and D Ex iaSYSTEM CALIBRATIONC alibration temperature:+23 C 5 CTarget material:VCL 140 steel ( )Note : If special calibration is required, please define the alloy precisely or supply a sample of alloy (min. 50 mm / 1 cm thick)TOTAL SYSTEM LENGTH (TSL)Due to the characteristics of the coaxial cable, an "electrical trimming" of the nominal length of the integral and extension cables is necessary to optimize the system performance and the transducer for a 5 m m minimumTSL for a 10 m m minimumSPECIFICATIONS (Continued)First draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E4 / 12 Performance Curves for tq 402 / 412 Transducer with IQS 452 Version 0XX or Version 1XX ConditionerProximity transducer: tq 402 / tq 412 Signal conditioner:IQS 452 Version 0XX or IQS 452 Version 1 XXStandard target material: VCL 140 ( )Equivalent materials.

5 A ( ), AFNOR 40 CD4, AISI 4137 SPECIFICATIONS (Continued)Conditioner output voltage (VDC)Typical sensitivity error referenced to 4 mV/ mTypical gap error ( m) referenced to 4 mV/ m lineMaximum temperature driftGAP (mm)4 mV/ mT = 23 CCopper, AluminiumStainless steelVCL 140 ( )standard targetFirst draft Vibro-Meter SA / 265-062 / / E5 / 12 Proximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Performance Curves for tq 402 / 412 Transducer with IQS 452 Version 2XX or Version 3XX ConditionerProximity transducer: tq 402 / tq 412 Signal conditioner:IQS 452 Version 2XX or IQS 452 Version 3 XXStandard target material: VCL 140 ( )Equivalent materials:A ( ), AFNOR 40 CD4, AISI 4137 SPECIFICATIONS (Continued)Conditioner output voltage (VDC)Typical sensitivity error referenced to 8 mV/ mTypical gap error ( m) referenced to 8 mV/ m lineMaximum temperature driftGAP (mm)8 mV/ mT = 23 CCopper, AluminiumStainless steelVCL 140 ( )standard targetFirst draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E6 / 12TQ 402 / tq 412 Proximity TransducerGENERALT ransducer input requirements:High-frequency power source via matching conditioner type IQS 452 ENVIRONMENTALT emperature ranges Transducer:-40 C to +180 C with drift < 5% (operation)+180 C to +220 C with drift > 5% (short-term survival) Cable:-100 C to +200 C Connector:-65 C to +85 C Heat shrinkable sleeve (modified Polyolefin):-55 C to +135 CProtection class (according to IEC 529 and DIN 40050).

6 The tip of the transducer is rated IP 67 The connection between the transducer body and its integral cable is rated IP 64 Transducer construction:Wire coil 8 mm, Torlon (polyamide-imide) tip, encapsulated in stainless steel body (AISI 316L) with high-temperature epoxy glueIntegral cable:FEP covered 70 coaxial cable, mm Option:BOA stainless steel armour sheathingNote : The BOA sheathing is not leaktight and the heat-shrinkable sleeve is splashproof onlyConnector:Miniature coaxial male connector type AMP 1-330 723-0NB : This should be hand-tightened only when connectingIQS 452 Signal ConditionerOUTPUT CHARACTERISTICSV oltage output, 3-wire configuration Voltage at min. V Voltage at max. V Dynamic range:16 V Output impedance:500 Short-circuit current:45 mACurrent output, 2-wire configuration Current at min. mA Current at max. mA Dynamic range:5 mAOutput capacitance:1 nFSPECIFICATIONS (Continued)First draft Vibro-Meter SA / 265-062 / / E7 / 12 Proximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Output inductance:100 HSUPPLYV oltage:-20 V to -32 VCurrent:13 1 mA (25 mA max.)

7 Supply input capacitance:1 nFSupply input inductance:100 HENVIRONMENTAL CHARACTERISTICS(According to DIN 40040)Temperature range Operation:-30 C to +70 C Storage:-40 C to +80 CHumidity Operation and storage:Max. 95% non condensingVibration Operation and storage:2 g peak between 10 Hz and 500 HzProtection class:IP 40 PHYSICAL CHARACTERISTICSC onstruction material:Injection moulded aluminiumELECTRICAL CONNECTIONSI nput:Stainless steel coaxial female socketOutput and power:Screw terminal stripWEIGHTS tandard version:Approx. 140 gExi version:Approx. 220 gSPECIFICATIONS (Continued)First draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E8 / 12 DIMENSIONS AND ORDERING INFORMATION tq 402 Proximity TransducerStainless steel BOA protection, minimum bending radius 50 mmFEP coaxial cable, minimum bending radius 20 mmHeat-shrinkable sleeveBodyThread (B) -24 UNF65/8 -18 UNF71/2 -20 UNF8 Blue marker sleeves for intrinsically safe version14 (HEX,) for M10x1 and 3/8 -24 UNF17 (HEX,) for 1/2 -20 UNF22 (HEX,) for othersTotal System Length (H)055 m length1010 m lengthMovable BOAfor tq 402 Optional stuffing gland, type SG 102(see separate data sheet)Movable BOA protectionTQ 4027 (2 Flats)Ordering Number : 111 - 402 - 000 -Environment (A)Standard1 Explosive2 Cable Protection (F)0 None1 BOA2 BOA + sleeve3 Movable BOA4 Movable BOA + sleeveBOA Length (G)Each m,from 0 to m000 None001 Min.

8 M100 Max. mBody Length (C)Each 1 mm,from 20 to 250 mmMin. 20 mm020 Max. 250 mm250 UnthreadedLength (D)Each 1 mm,from 0 to 230 mmMin. 0 mm000 Max. 230 mm230 Integral Cable (E) m length0051 m m length0152 m length0205 m length05010 m length100 ABCDEFGHN otes :(1) All dimensions are in mm.(2) The total system length (dimension H ) is the sum of the lengths of the integral cable and the extension cable.(3) For details on cable length tolerances, please refer to the section Total System Length (TSL) on page draft Vibro-Meter SA / 265-062 / / E9 / 12 Proximity SystemTQ 402 & tq 412 / EA 402 / IQS 452TQ 412 Proximity TransducerEA 402 Extension CableDIMENSIONS AND ORDERING INFORMATION (Continued)Stainless steel BOA protection, minimum bending radius 50 mmFEP coaxial cable, minimum bending radius 20 mmHeat-shrinkable sleeveOrdering Number : 111 - 412 - 000 - 01 Environment (A)Standard1 Explosive2 Cable Protection (F)None0 BOA1 BOA + sleeve2 Movable BOA3 Movable BOA + sleeve4 BOA Length (G)Each m,from 0 to m000 None001 Min.

9 M100 Max. mTotal System Length (H)055 m length1010 m lengthBody Thread (B)M10x113/8 -24 UNF6 Blue marker sleeves for intrinsically safe version14 (HEX,) for M10x1 and 3/8 -24 UNF10 (2 FLATS)13/32 (2 FLATS)Integral Cable (E) m length0051 m m length0152 m length0205 m length05010 m length100 ABEFGHM ovable BOAfor tq 412 Optional stuffing gland, type SG 102(see separate data sheet)Movable BOA protectionTQ 412 Notes :(1) All dimensions are in mm.(2) The total system length (dimension H ) is the sum of the lengths of the integral cable and the extension cable.(3) For details on cable length tolerances, please refer to the section Total System Length (TSL) on page draftProximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 Vibro-Meter SA / 265-062 / / E10 / 12 DIMENSIONS AND ORDERING INFORMATION (Continued)Environment (A)Standard1 Explosive2 Cable Length (E) m095 Cable Protection (F)None0 BOA1 BOA + sleeve2 Ordering Number : 913 - 402 - 000 - 01 AEFGBOA Length (G) mNote : (1) All dimensions are in mm unless otherwise stated.

10 (2) For details on cable length tolerances, please refer to the section Total System Length (TSL) on page steel BOA protection,minimum bending radius 50 mmFEP coaxial cable,minimum bending radius 20 mmon the shrinksleeveBlue marker sleeves for intrinsically safe versionFirst draft Vibro-Meter SA / 265-062 / / E11 / 12 Proximity SystemTQ 402 & tq 412 / EA 402 / IQS 452 IQS 452 Signal ConditionerDIMENSIONS AND ORDERING INFORMATION (Continued)To order please specify :IQS TypeMeasuring RangeModeSensitivityTotal System LengthVersionOrdering NumberIQS 452,versionsM0 XXor M1XX4 mmVoltageoutput,3-wireconfiguration4 mV/ m5 m10 m5 m10 mStandardStandardExiExi204-452-000-01204 -452-000-02204-452-000-03204-452-000-04 Currentoutput,2-wireconfiguration 1) A/ m5 m10 m5 m10 mStandardStandardExiExi204-452-000-11204 -452-000-12204-452-000-13204-452-000-14 IQS 452,versionsM2 XXor M3XX2 mmVoltageoutput,3-wireconfiguration8 mV/ m5 m10 m5 m10 mStandardStandardExiExi204-452-000-21204 -452-000-22204-452-000-23204-452-000-24 Currentoutput,2-wireconfiguration 1) A/ m5 m10 m5 m10 mStandardStandardExiExi204-452-000-31204 -452-000-32204-452-000-33204-452-000-341 )


Related search queries