Current as at 23/02/2015 TRACHEOSTOMY SIZING CHART PORTEX BLUE LINE ULTRA and PORTEX SUCTIONAID TRACHEOSTOMY TUBES Size ID (mm) ID with Inner Cannula (mm) OD (mm) Length (mm) Cuff OD(mm) 6 7 8 9 10 PORTEX BLUE LINE ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff OD(mm) 6 59-81 7 64-84 8 73-97 9 78-111 10 84-123 PORTEX UNIPERC ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) without inner cannula ID with Inner Cannula (mm) OD (mm) Length (mm) 7 62 8 68 9 74 BIVONA (TTS* and CUFFLESS) TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff (mm) 6 7 8 9 N/A BIVONA AIRE CUFF TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff (mm) 6 7 8 9 BIVONA HYPERFLEX ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Maximum Length (mm) Cuff(mm) 6 11 7 12 8 13 9 WATER in cuff AIR in cuff WATER in cuff Only use in ICU/HDU AIR in cuff Suctionaid model has above cuff line AIR in cuff AIR in cuff Has inner cannula Copyright 2016 by Austin HealthDisclaimer: This document has been developed by Austin Health and has been specifi cally designed for Austin Health circumstances.

Current as at 23/02/2015 promotional activities where versions of this document are used. The information is current at the date of printing. Clinical practices may change and updates to this material

Tags:

  Chart, Sizing, Tracheostomy, Tracheostomy sizing chart

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TRACHEOSTOMY SIZING CHART

1 Current as at 23/02/2015 TRACHEOSTOMY SIZING CHART PORTEX BLUE LINE ULTRA and PORTEX SUCTIONAID TRACHEOSTOMY TUBES Size ID (mm) ID with Inner Cannula (mm) OD (mm) Length (mm) Cuff OD(mm) 6 7 8 9 10 PORTEX BLUE LINE ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff OD(mm) 6 59-81 7 64-84 8 73-97 9 78-111 10 84-123 PORTEX UNIPERC ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) without inner cannula ID with Inner Cannula (mm) OD (mm) Length (mm) 7 62 8 68 9 74 BIVONA (TTS* and CUFFLESS) TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff (mm) 6 7 8 9 N/A BIVONA AIRE CUFF TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Length (mm) Cuff (mm) 6 7 8 9 BIVONA HYPERFLEX ADJUSTABLE FLANGE TRACHEOSTOMY TUBES Size ID (mm) OD (mm) Maximum Length (mm) Cuff(mm) 6 11 7 12 8 13 9 WATER in cuff AIR in cuff WATER in cuff Only use in ICU/HDU AIR in cuff Suctionaid model has above cuff line AIR in cuff AIR in cuff Has inner cannula Copyright 2016 by Austin HealthDisclaimer: This document has been developed by Austin Health and has been specifi cally designed for Austin Health circumstances.

2 Austin Health shall not be liable forany claims or loss arising from the use of this document and information in any organization outside of Austin Health. Other clinicians and institutions are granted license touse this clinical instruction sheet and to modify it for their own purposes. It is a condition of this license that Austin Health TRAMS is acknowledged within all educational andpromotional activities where versions of this document are used. The information is current at the date of printing. Clinical practices may change and updates to this materialwill not be provided by Austin as at 23/02/2015 SHILEY XLT TRACHEOSTOMY TUBES SHILEY FLEXIBLE TRACHEOSTOMY TUBES (CN/UN) Size(mm) ID (mm) without inner cannula ID with Inner Cannula (mm) OD (mm) Length (mm) 4 62 5 68 6 74 7 77 8 79 9 79 10 79 SHILEY STANDARD TRACHEOSTOMY TUBES (DCT/DFEN/DCFS/DCFN) Size ID (mm) OD (mm) Length (mm) 4 62 6 74 8 79 10 79 Shiley XLTD extra length distally For long tracheal anatomy, tracheal stenosis or malacia Shiley XLTP extra length proximally For swollen or thick neck anatomy Copyright 2016 by Austin HealthDisclaimer: This document has been developed by Austin Health and has been specifi cally designed for Austin Health circumstances.

3 Austin Health shall not be liable forany claims or loss arising from the use of this document and information in any organization outside of Austin Health. Other clinicians and institutions are granted license touse this clinical instruction sheet and to modify it for their own purposes. It is a condition of this license that Austin Health TRAMS is acknowledged within all educational andpromotional activities where versions of this document are used. The information is current at the date of printing. Clinical practices may change and updates to this materialwill not be provided by Austin as at 23/02/2015 COOK VERSA TRACHEOSTOMY TUBE Size(mm) ID (mm) ID with Inner Cannula (mm) OD (mm) Length (mm) Cuff OD(mm) Angle ( ) Colour code 7 96 Green 8 96 White 9 98 Blue TRACOE COMFORT TRACOE TWIST PLUS Copyright 2016 by Austin HealthDisclaimer: This document has been developed by Austin Health and has been specifi cally designed for Austin Health circumstances.

4 Austin Health shall not be liable forany claims or loss arising from the use of this document and information in any organization outside of Austin Health. Other clinicians and institutions are granted license touse this clinical instruction sheet and to modify it for their own purposes. It is a condition of this license that Austin Health TRAMS is acknowledged within all educational andpromotional activities where versions of this document are used. The information is current at the date of printing. Clinical practices may change and updates to this materialwill not be provided by Austin Health.


Related search queries