Example: confidence

Trane Advantage VRF Outdoor Unit / Product Catalog

Variable Refrigerant Flow (VRF)Air Source Heat Pump and Heat RecoveryOutdoor Units4 TVH*/4 TVR*February 2015 VRF-PRC008B-ENProduct Catalog 2015 Trane All rights reservedVRF-PRC008B-ENIntroductionTrane VRF variable refrigerant systems are efficient, effective, reliable heating and coolingsolutions you can trust. When VRF is the right solution for your application, Trane will help youensure it's the best is well suited for historic buildings without existing ductwork, aswell as schools and mid-rise office buildings with multiple interior spaces and diverse VRF systems are designed for exceptional energy efficiency, offering industry leadingperformance up to 33 IEER and 32 VRF utilizes inverter compressors (some modelfeature dual compressors) with vapor injection for improved performance and are available for both heat pump and simultaneous heating and cooling operation.

Application matrix Capacity 7.5 MBh 9.0 MBh 9.5 MBh 12 MBh 18 MBh 20 MBh 24 MBh 30 MBh 36 MBh 42 MBh 48 MBh 60 MBh 76.8 MBh 96 MBh Type Slim one ... VRF Wireless Remote Control TVCTRLTRDH00UT ... Product Specifications Outdoor Units

Tags:

  Product, Wireless, Matrix, Trane

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Trane Advantage VRF Outdoor Unit / Product Catalog

1 Variable Refrigerant Flow (VRF)Air Source Heat Pump and Heat RecoveryOutdoor Units4 TVH*/4 TVR*February 2015 VRF-PRC008B-ENProduct Catalog 2015 Trane All rights reservedVRF-PRC008B-ENIntroductionTrane VRF variable refrigerant systems are efficient, effective, reliable heating and coolingsolutions you can trust. When VRF is the right solution for your application, Trane will help youensure it's the best is well suited for historic buildings without existing ductwork, aswell as schools and mid-rise office buildings with multiple interior spaces and diverse VRF systems are designed for exceptional energy efficiency, offering industry leadingperformance up to 33 IEER and 32 VRF utilizes inverter compressors (some modelfeature dual compressors) with vapor injection for improved performance and are available for both heat pump and simultaneous heating and cooling operation.

2 Bothfeature individual zone control to provide individual occupant simultaneous heatingand cooling models offer the ability to heat and cool adjacent zones, intelligently exchangingenergy between them through strategically located mode control units are available in a wide variety of configurations and capacities, allowing architects theflexibility to satisfy almost any design offers a complete line-up of controls to complete yourVRF range fromeasy to use individual zone controls, to centralized systems for building monitoring and control,as well as optional BACnet connectivity for centralizedTrane Tracer of all, yourTrane VRF system is supported by theTrane nationwide network of sales andservice document and the information in it are the property ofTrane, and may not be used orreproduced in whole or in part without written reserves the right to revise thispublication at any time, and to make changes to its content without obligation to notify any personof such revision or trademarks referenced in this document are the trademarks of their respective HistoryVRF-PRC008B-EN (17 February 2015) AHRI-1230 ratings updated and now include larger capacity systems previously not covered.

3 Low ambient heating range expanded from -4 F to -13 of of 4 Model Number 10 Operation Limit - Outdoor Correction 31 Electrical Wiring Diagrams - Outdoor Levels - Outdoor 38 Sound 40NR 40 Cycle of Outdoor Unit (HP).. 42 Parts of Outdoor Unit (HR).. 45 Dimensional Pump/Heat 484 VRF-PRC008B-ENSystem Features Individual modules are available as standard heat pump or simultaneous heating and cooling(heat recovery) configuration; units can be combined as double or triple modules for largercapacity requirements. 3rdgenerationcompressortechnologyfeature sallinvertercompressorsforsuperioreffici encyand reliability Asymmetric scroll is designed to minimize frictional loss Dual inverter compressors (available in many models) are designed to equally share load forhigher reliability Improved vapor injection system increases refrigerant flow rate up to 20% for superior heatingperformance Intercooler uses a plate heat exchanger for improved heating and cooling efficiency 8,400 RPM (maximum speed)

4 Compressor assures quick start cooling and heating performance Auto oil balancing eliminates the need for an oil balancing pipe Compressor inverter drives are liquid cooled for improved reliability Longer pipe lengths are the result of large oil storage capacity and low oil circulation rate Total harmonic distortion is reduced through adaptive sine wave control Refrigerant pump down and pump out facilitates maintenance and repair Automatic refrigerant balancing between indoor units optimize refrigerant distribution forbetter comfort and performance Optional quiet operation mode for reduced sound levels at night Auto snow blowing function removes accumulated snow when conditions require it Special hydrophilic heat exchanger coating minimizes frost build up on the Outdoor coils andfacilitates the defrost cycle.

5 Anti-corrosion finish provides added protection in harsh environments Four and six port mode control units are light and compact. Distributed installation flexibilityprovides superior performance during simultaneous heating and cooling operation. Trane VRF systems feature self-diagnosis, including system monitoring and error codereportingVRF-PRC008B-EN5 Digit 1 Refrigerant4 = R-410 ADigit 2 Brand NameT = TraneDigit3 SystemTypeV = Variable Refrigerant FlowDigit4 FunctionalTypeOutdoor UnitH = Heat Pump, DC Inverter (VRF)R = Heat Recovery (three pipe), DCInverterDigit 5 Special Application0 = StandardDigit 6,7,8 Nominal CapacityImportant:Btuh x1,000072 = 72,000 Btuh096 = 96,000 Btuh120 = 120,000 Btuh144 = 144,000 Btuh4 TVR0096B300NB1234567891011121314 Digit 9 Major DevelopmentSequenceB = Second Development SequenceDigit 10 Electric Power SupplyCharacteristics3 = 208 230/60/34 = 460/60/3 Digit 11 Reserved for FutureUse0 = Not currently usedDigit 12 Reserved for FutureUse0 = Not currently usedDigit 13 Region of SaleN = North America (UL or ETL)Digit 14 Minor DesignSequenceB = Second Design SequenceSystem Combination Line-upTons 4 TVH/R0072B 4 TVH/R0096B 4 TVH/R0120B 4 TVH/R0144 BSingle Module6181101121 Double Module1411161118112022211242 Triple Module2611128111301232213412363 Model Number Descriptions6 VRF-PRC008B-ENProductsTable 1.

6 Application MBh12 MBh18 MBh20 MBh24 MBh30 MBh36 MBh42 MBh48 MBh96 MBhTypeSlim one way cassetteXXXFour way cassetteXXXXXXXMini four way cassette XXXXSlim ductXXXXXXXXMSP ductXXXXXHSP ductXXXXC eilingXXHigh WallXXXXXXC onvertible AHUXXXXXXVRF-PRC008B-EN7 ControlsControlsTable 2. Controls forVRF ProductsFamilyDescriptionModel NumberZone ControllersVRF wireless Remote ControlTVCTRLTRDH00 UTVRF Simple Wired Remote ControlTVCTRLWR001 TVRF Wired Remote ControlTVCTRLTWRWD01 TVRF Duct Signal Receiver & WireTVCTRLTRKA10N0 Centralized Control SystemsVRF Central On/Off ControlTVCTRLTCMA202 DVRF Touch Screen ControlTVCTRLTCMA300 TVRF Mode Select SwitchTVCTRLTCMC2000 Integrated System Management VRF System ControllerTVCTRLTIMD00A0 VRF Enterprise Management SoftwareTVCTRLTSTP3P00 VRF Power Meter Interface Management System GatewaysVRF System Controller + BACnetTVCTRLTIMB17A0 VRF System Controller + LonTalk TVCTRLTIMB18A0 Interface ModulesVRF External Contact Interface ModuleTVCTRLTIMB14A0 VRF Multi Function

7 ControlTVCTRLTC210N00 VRF MFC EnclosureTVCTRLTC210 BOXR equired control box for 4 TVM air handling unit4 TVCTRLAU001 SensorsVRF Ext. Room Temp SensorTVCTRLTRWTA000 VRF Motion Sensor Mini 4 WayMOTIONSEN4 TVBC ommissioning and Utility KitsVRF Technician Utilities ToolTVCTRLTIMC0300 VRF Auto-Commissioning ToolTVCTRLTIMC10008 VRF-PRC008B-ENAccessoriesAccessoriesTabl e 3. Accessories forVRF ProductsFamilyDescriptionModel NumberRefrigeration JointsVRF Y-joint <51 MBh4 YDK1509B0051 AVRF Y-joint 51-138 MBh4 YDK2512B0138 AVRF Y-joint 138-160 MBh4 YDK2812B0160 AVRF Y-joint 160-240 MBh4 YDK2815B0240 AVRF Y-joint 240-336 MBh4 YDK3419B0336 AVRF Y-joint 336-468 MBh4 YDK4119B0468 AVRF Y-joint >468 MBh4 YDK4422B0999 AVRF Y-joint HR <80 MBh4 YDK1500B0080 AVRF Y-joint HR 80-240 MBh4 YDK2500B0240 AVRF Y-joint HR 240-468 MBh4 YDK3100B0468 AVRF Y-joint HR >468 MBh4 YDK3800B0999 AVRF T-joint >468 MBh4 TDK3800B0999 AVRF T-joint <468 MBh4 TDK3819B0000 AVRF T-joint HR <468 MBh4 TDK3100B0000 AVRF T-joint HR >468 MBh4 TDK4422B0999 AHeader JointsVRF Header Joint 4 Units<160 MBh4 HJK2512B0159 AVRF Header Joint 8 Units 240 MBh4

8 HJK3115B0241 AVRF Header Joint 8 Units<160 MBh4 HJK3819B0998 AEEV Kits (For Floor/Ceiling and Selected High Wall Indoor UnitsVRF EEV Kit 1 Unit EEV Kit 1 Unit 17-31 MBh4 EEVEVA32SA000 VRF EEV 1x 1x 17-31 MBh4 EEVXDA24K132 AVRF EEV Kit 2 Unit EEV 2x 1x 17-31 MBh4 EEVXDA24K232 AVRF EEV Kit 2 Unit 17-31 MBh4 EEVXDA32K200 AVRF EEV 1x 2x 17-31 MBh4 EEVXDA32K224 AVRF EEV Kit 3 Unit EEV Kit 3 Unit 17-31 MBh4 EEVXDA32K300 AAHU KitsVRF AHU Kit 24-30 MBh4 EEVAKA40K1025 VRF AHU Kit 48-60 MBh4 EEVAKA40K1050 VRF AHU Kit 72-90 MBh4 EEVAKA64K1075 VRF AHU Kit 96-112 MBh4 EEVAKA64K1100 VRF-PRC008B-EN9 AccessoriesCondensate PumpsVRF Drain Pump High Wall and Floor/CeilingCONDPUMPAHWB01 VRF Drain Pump Slim DuctCONDPUMPXVLB01 VRF Drain Pump MSP 18/24 MBhCONDPUMPXVMB01 VRF Drain Pump MSP 30/36 MBhCONDPUMPXVMB02 VRF Drain Pump MSP48/ HSP3648 MBhCONDPUMPXVDB01 VRF Drain Pump HSP Control Units (for Simultaneous Heating and Cooling Applications)VRF MCU Kit up to 4 IDU4 MCUCUY4 NCE000 VRF MCU Kit up to 6 IDU4 MCUCUY6 NCE000 VRF MCU Kit 2 IDU 36 MBh +4 MCUCUY2 NCE000 Ball Valves1/2" Ball Valve FlareBVALVE12 FLARE11/4" Ball Valve FlareBVALVE14 FLARE13/8" Ball Valve FlareBVALVE38 FLARE15/8" Ball Valve FlareBVALVE58 FLARE1 Cassette PanelsVRF Cass.)

9 Panel Sliding 1 WayTVEPANPC1 NUAETVRF Cass. Panel Slim 1 WayTVEPANPC1 NUSETVRF Cass. Panel 4 WayTVEPANPC4 NUSETVRF Cass. Panel Mini 4 WayTVEPANPC4 SUSETP ressure Differential Module (for high rise applications)Pressure Diff Module 6/8/10 Ton MXD-A12K2 APressure Diff Module 12 Ton MXD-A38K2 AHail GuardsHail Guard 4 TVH/TVR0072B TVRGARD001 AHail Guard 4 TVH/TVR0096-0144B TVRGARD002 AHail Guard 4 TVH0036-0053B TVRGARD003 ATable 3. Accessories forVRF Products (continued)FamilyDescriptionModel Number10 VRF-PRC008B-ENProduct SpecificationsOutdoor UnitsTable 4. 208-230V Heat Pump Single ModulesModel Name4 TVH0072B300NB 4 TVH0096B300NB 4 TVH0120B300NB 4 TVH0144B300 NBPower Supply208-230/60/3208-230/60/3208-230/60 /3208-230/60/3 PerformanceNominal TypeDuctedNon-ductedDuctedNon-ductedDuct edNon-ductedDuctedNon-ductedCapacity(Nom inal)(a)CoolingBtuh72,00072,00096,00096, 000120,000120,000144,000144,000 HeatingBtuh81,00081,000108,000108,000135 ,000135,000162,000162,000 Capacity(Rated)(b)CoolingBtuh69,00069,00 092,00092,000114,000114,000138,000138,00 0 High Temp HeatingBtuh77,00077,000103,000103,000129 ,000129,000154,000154,000 Low Temp HeatingBtuh51,00051,00067,00067,00084,00 084,000100,000100,000 AHRI -1230 Efficiency Ratings(b) @ 47 @ 17 -- --- (Qty.)

10 -SSC SCROLL (1)SSC SCROLL (2)SSC SCROLL (2)SSC SCROLL (2)Model Name-DS-GB052 FBVASGDS-GB052 FBVASG (2) DS-GB052 FBVASG (2)DS-GB052 FBVASG (2)OutputkW Chargefl. (Qty.)-Propeller (1)Propeller (2)Propeller (2)Propeller (2)Output (Each)W400620620620 Airflow RateCFM7,2409,1809,1809,535 External Static PressureIn. ConnectionsLiquid Pipe inch3/8" Braze3/8" Braze1/2" Braze1/2" BrazeGas Pipe inch3/4" Braze7/8" Braze1 1/8" Braze1 1/8" BrazeHigh Pressure Gas Pipe (For HR) inchN/AN/AN/AN/AInstallation LimitsMax Length(c) (722)656 (722)656 (722)656 (722)Max Height(d) (131)361 (131)361 (131)361 (131)Indoor Unit ConnectionsNumber Of Connectable Indoor Units-12162025 Total Capacity-50 To 130% Of Total Outdoor Unit CapacityRefrigerantType-R-410AR-410AR-41 0AR-410 AFactory (e)Sound PressuredB(A) PowerdB(A)81818183 External DimensionsNet Dimensions (WXHXD) X X X X 30, X X 30, X X Dimensions (WXHXD) X X X X X X X X Temp RangeCooling F23 ~ 12023 ~ 12023 ~ 12023 ~ 120 Heating F-13 ~ 75-13 ~ 75-13 ~ 75-13 ~ 75(a)


Related search queries