Transcription of Trane Split System Heat Pump 3-Phase 4TWA7
1 May 201622-1925-1A-ENSplit System Heat Pump3 Phase4 TWA7036A3000A4 TWA7048A3000A4 TWA7060A3000A4 TWA7036A4000A4 TWA7048A4000A4 TWA7060A4000 ANNoottee:: Graphicsinthisdocumentareforrepresentati ononly. Actualmodelmaydifferinappearance. Product 5 AccessoryDescriptionand 6 ModelNomenclature.. 6 SCHEMATIC .. 10 Table of Contents22-1925-1A-EN3 Product SpecificationsModelNo.(a) (b)4 TWA7036A3000A4 TWA7048A3000A4 TWA7060A3000 APOWERCONNS. V/PH/HZ(c)230/3/60230/3/60230/3/60 MIN. CIR. PROT. RTG. MAX. (AMPS)253035 COMPRESSORCLIMATUFF -SCROLLCLIMATUFF -SCROLLCLIMATUFF AMPS(d) 7314 110 OutdoorFan FL HP1/81/51/4 Fan Dia (inches) SPINEFIN SPINEFIN RefrigerantR-410A(e)10 LBS.
2 , 8 OZ12 LBS., 09 OZ13 LBS., 03 OZLINE SIZE IN. GAS(f) (g)3/47/81 1/8 LINE SIZE IN. LIQ.(h)3/83/83 F8 F10 FDimensionsH xW X D Crated(IN.) x x x x x Shipping(lbs.)307329330 Weight Net (lbs.)257292293 OptionalAccessories:Anti-shortCycleTimer TAYASCT501 ATAYASCT501 ATAYASCT501 AEvaporator DefrostControlNANANAR ubberIsolatorKitBAYISLT101 BAYISLT101 BAYISLT101 ExtremeConditionMountKitBAYECMT023 BAYECMT004 BAYECMT004 CrankcaseHeaterKit SeacoastKitBAYSEAC001 BAYSEAC001 BAYSEAC001 Low AmbientKitBAYLOAM107 BAYLOAM107 BAYLOAM107 RefrigerantLineset(i)TAYREFLN7*TAYREFLN3 *TAYREFLN3*SoundEnclosureBAYSDEN003 BAYSDEN004 BAYSDEN004 Snow Legs 6 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Legs Extension 4 BAYLEGS003 BAYLEGS003 BAYLEGS003 ServiceValve Panel CoverTAYSVPANL3343 AATAYSVPANL0044 AATAYSVPANL0044AA(a)
3 Certifiedin accordancewiththe Air-SourceUnitaryAir-conditionerEquipmen tcertificationprogram,which is based on AHRI standard210/240.(b)Ratedin accordancewith AHRI standard270.(c)Calculatedin use HACR circuitbreakersor fuses.(d)This value shownfor compressorRLA on the unit nameplateand on this specificationsheetis used to size. The valueshownis the branchcircuitselectioncurrent.(e)This value precisevaluesee unit nameplate.(f)Referencethe outdoorunit ship-withliteraturefor refrigerantpipinglengthand lift refrigerantpipingsoftwarepub # 32-3312-xxor refrigerantpipingapplicationguide SS-APG006-xx for longline setsor specialtyapplications(xx denoteslatest revision).
4 (g)Traneoutdoorcondensingunits are factorychargedwith thesystemchargerequiredfor theoutdoorcondensingunit and 15 feetof testedconnectinglines. If connectingline lengthexceeds15 feet, then final refrigerantchargeadjustmentis necessary. Each additionalfoot over 15 feet ozs the Installer s Guide for full charginginstructions.(h)This value precisevaluesee unit nameplate.(i)* = 15, 20, 25, 30, 40 and50 foot (a) (b)4 TWA7036A4000A4 TWA7048A4000A4 TWA7060A4000 APOWERCONNS. V/PH/HZ(c)460/3/60460/3/60460/3/60 MIN. CIR. PROT. RTG. MAX. (AMPS)151515 COMPRESSORCLIMATUFF -SCROLLCLIMATUFF -SCROLLCLIMATUFF AMPS(d) 52 OutdoorFan FL HP1/81/51/4 Fan Dia (inches) SPINEFIN SPINEFIN RefrigerantR-410A(e)10 LBS.
5 , 8 OZ12 LBS., 09 OZ13 LBS., 03 OZLINE SIZE IN. GAS(f) (g)3/47/81 1/8 LINE SIZE IN. LIQ.(h)3/83/83 F8 F10 FDimensionsH xW X D Crated(IN.) x x x x x Shipping(lbs.)307323326 Weight Net (lbs.)257286289 OptionalAccessories:Anti-shortCycleTimer TAYASCT501 ATAYASCT501 ATAYASCT501 AEvaporator DefrostControlNANANAR ubberIsolatorKitBAYISLT101 BAYISLT101 BAYISLT101 ExtremeConditionMountKitBAYECMT023 BAYECMT004 BAYECMT004 CrankcaseHeaterKit SeacoastKitBAYSEAC001 BAYSEAC001 BAYSEAC001 Low AmbientKitBAYLOAM107 BAYLOAM107 BAYLOAM107 RefrigerantLineset(i)TAYREFLN7*TAYREFLN3 *TAYREFLN3*SoundEnclosureBAYSDEN003 BAYSDEN004 BAYSDEN004 Snow Legs 6 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Legs Extension 4 BAYLEGS003 BAYLEGS003 BAYLEGS003 ServiceValve Panel CoverTAYSVPANL3343 AATAYSVPANL0044 AATAYSVPANL0044AA(a)
6 Certifiedin accordancewiththe Air-SourceUnitaryAir-conditionerEquipmen tcertificationprogram,which is based on AHRI standard210/240.(b)Ratedin accordancewith AHRI standard270.(c)Calculatedin use HACR circuitbreakersor fuses.(d)This value shownfor compressorRLA on the unit nameplateand on this specificationsheetis used to size. The valueshownis the branchcircuitselectioncurrent.(e)This value precisevaluesee unit nameplate.(f)Referencethe outdoorunit ship-withliteraturefor refrigerantpipinglengthand lift refrigerantpipingsoftwarepub # 32-3312-xxor refrigerantpipingapplicationguide SS-APG006-xx for longline setsor specialtyapplications(xx denoteslatest revision).
7 (g)Traneoutdoorcondensingunits are factorychargedwith thesystemchargerequiredfor theoutdoorcondensingunit and 15 feetof testedconnectinglines. If connectingline lengthexceeds15 feet, then final refrigerantchargeadjustmentis necessary. Each additionalfoot over 15 feet ozs the Installer s Guide for full charginginstructions.(h)This value precisevaluesee unit nameplate.(i)* = 15, 20, 25, 30, 40 and50 foot SSppeecciiffiiccaattiioonnss22-1925-1A-E N5 SoundPower LevelSoundPowerLevelMODELA-WeightedSound PowerLevel[dB(A)]FullOctaveSoundPower(dB )63 Hz 125 Hz 250 Hz500 Hz1000 Hz 2000Hz4000Hz8000Hz4 TWA7036A7274717270696259554 TWA7048A7385746869696358544 TWA7060A747571717170655852622-1925-1A-EN AccessoryDescription and UsageAAnnttii--SShhoorrtt CCyyccllee TTiimmeerr Solid statetimingdevicethat preventscompressorrecyclinguntilfive (5)
8 Minuteshaveelapsedafter satisfyingcall or in area withquestionablepowerdelivery, commercialapplications,long lineset, DDeeffrroosstt CCoonnttrrooll SPSTT emperatureactuatedswitch that cyclesthe condenseroff as indoorcoil reaches low ambientcoolingto 30 F with IIssoollaattoorrss Five (5) largerubberdonutsto isolatecondensingunit fromtransmittingenergyinto mountingframeor pad. Use on any applicationwheresoundtransmissionneedsto be SSttaarrtt KKiitt Start capacitorand relayto assistcompressormotorstartup. Use in areaswithmarginalpowersupply, on long linesets,low ambientconditions, CCoonnddiittiioonn MMoouunntt KKiitt Bracket kits to securelymountcondensingunit to a frameorpad withoutremovingany in areaswith high winds,or on commercialroof tops, SSttaannddaarrdd CCaappaacciittyy RRaattiinngg CCoonnddiittiioonnssAHRIS tandard210/240 RatingConditions1.
9 Cooling80 F DB, 67 F WB air enteringindoorcoil, 95 F DB air HighTemperatureHeating47 F DB, 43 F WB air enteringoutdoorcoil, 70 F DB air Low TemperatureHeating17 F DB air Rated indoorairflowfor heatingis the sameas for SSttaannddaarrdd 227700 RRaattiinngg CCoonnddiittiioonnss (Noiseratingnumbers are determiendwith the unit incoolingoperations.)StandardNoiseRating numberis at 95 F Type2 = R-224 = R-410 ATRANEP roduct TypeW = Split Heat PumpT = Split CoolingProduct FamilyV = Variable Speed M or B = BasicZ = Leadership Two Stage A = Light CommercialX = LeadershipR = Replacement/RetailFamily SEER3 = 13 6 = 16 0 = 204 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons0 = BrazedNominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60 Secondary FunctionMinor Design ModificationsUnit Parts IdentifierOutdoor Units4 TWV0036A1000AA22-1925-1A-EN7 SCHEMATIC230 VHP
10 D159297P02822-1925-1A-EN460 VHP D159194P02 SSCCHHEEMMAATTIICC22-1925-1A-EN9 OutlineDrawingModelBaseABCDEFGHJK4 TWA7036A41147(45 1/8)946(37 1/4)870(34 1/4)3/43/8152(6)98(3 7/8)219(8 5/8)86(3 3/8)813(32)4 TWA7048A41147(45 1/8)946(37 1/4)870(34 1/4)7/83/8152(6)98(3 7/8)219(8 5/8)86(3 3/8)813(32)4 TWA7060A41147(45 1/8)946(37 1/4)870(34 1/4)1 1/83/8152(6)98(3 7/8)219(8 5/8)86(3 3/8)813(32)1022-1925-1A-ENMechanicalSpec ificationOptionsGGeenneerraallThe OutdoorUnitsare fully chargedfromthe factoryfor up to 15 feet of unit isdesignedto operateat outdoorambienttemperaturesas high as 115 F. Coolingcapacitiesarematched with a wideselectionof air handlersand furnacecoils that are unit iscertifiedto UL 1995.