Example: marketing

Transmitter in Field Housing PR5230 - minebea …

Instrument Manual Transmitter in Field Housing PR5230 9499 050 52301 Instrument Manual Edition 4 for PR5230 Release: sartorius Mechatronics T&H GmbH, Meiendorfer Str. 205, 22145 Hamburg, Germany Tel:+ Fax:+ Please note Any information in this document is subject to change without notice and does not represent a commitment on the part of sartorius unless legally prescribed. This product should be operated only by trained and qualified personnel. In correspondence concerning this product the type, name and release number as well as all license numbers in relation to the product have to be quoted. Bitte beachten Alle Angaben in diesem Dokument sind - soweit nicht gesetzlich vorgegeben - unverbindlich f r sartorius und stehen unter nderungsvorbehalt.

Instrument Manual. Transmitter in Field Housing PR5230 . Instrument Manual . 9499 050 52301 . Edition 4 . 09.09.2010 . for PR5230 . Release: 1.00 . Sartorius Mechatronics T&H GmbH, Meiendorfer Str. 205, 22145 Hamburg, Germany

Tags:

  Field, Transmitter, Housing, Sartorius, Transmitter in field housing pr5230, Pr5230

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Transmitter in Field Housing PR5230 - minebea …

1 Instrument Manual Transmitter in Field Housing PR5230 9499 050 52301 Instrument Manual Edition 4 for PR5230 Release: sartorius Mechatronics T&H GmbH, Meiendorfer Str. 205, 22145 Hamburg, Germany Tel:+ Fax:+ Please note Any information in this document is subject to change without notice and does not represent a commitment on the part of sartorius unless legally prescribed. This product should be operated only by trained and qualified personnel. In correspondence concerning this product the type, name and release number as well as all license numbers in relation to the product have to be quoted. Bitte beachten Alle Angaben in diesem Dokument sind - soweit nicht gesetzlich vorgegeben - unverbindlich f r sartorius und stehen unter nderungsvorbehalt.

2 Die Bedienung des Produktes darf nur von geschultem, fach- und sachkundigem Personal durchgef hrt werden. Bei Schriftwechsel ber dieses Produkt bitte Typ, Bezeichnung und Versionsnummer sowie alle mit dem Produkt in Zusammenhang stehenden Lizenznummern angeben. PR5230 Instrument Manual List of Contents sartorius EN-3 List of Contents 1 Safety Information ..9 Electrical Protective Intended Initial Before Installation ..9 Opening the Instrument ..10 Connection of a protective earth conductor to PR5230 ..10 Power Connection PR5230 ..10 Failure and Excessive Stress ..11 Important Maintenance and 2 Transmitter in Field Housing ..12 Overview of the Instrument.

3 12 Communication Housing ..13 Housing Display and Controls ..14 Display ..14 Status LEDs ..16 Buttons ..17 Operating via VNC ..17 Operation Using Softkeys ..20 Selection Using the Navigation Keys (VNC)..20 Tool Tip (VNC) ..21 Overview of Plug-in Cards/Junction 3 Option Safety Description ..25 Marking ..25 In Connection with Option W1 ..25 In Connection with Option WE1 ..25 Installation ..26 Repairs/ Environmental List of Contents PR5230 Instrument Manual EN-4 sartorius Option WE1 ..27 Safety Description ..27 Marking ..27 In Connection with Option Y2 ..27 Weighing Electronic Board for Zone 1 and 21 ..28 Connection within the Ex Installation.

4 30 Repairs/ Technical Data ..35 4 Installing the Instrument and Plug-in Mechanical Preparation ..37 Hardware Construction ..37 Main Display Weighing Electronic Board ..39 Cable Gland and Network Port ..42 Optocoupler Opto-decoupled Outputs (optional)..44 Relay Outputs ..45 Interface RS-485 ..46 Interface RS-232 ..54 Installing Plug-in PR5230 /06 Analog Output Board ..57 PR5230 /22 Load Cell Junction Board ..58 PR1721/41 ProfiBus-DP Interface ..59 PR1721/42 InterBus-S Interface ..61 PR1721/44 DeviceNet Interface ..63 PR1721/45 CC-Link PR1721/46 ProfiNet I/O PR1721/47 EtherNet-IP PR5230 /30 Ethernet PR5230 /31 Ethernet Cable.

5 72 Connecting Load Cells ..73 Connecting a Load Cell with 4-Wire Connecting PR6221 Load Cells ..73 Connecting up 2 to 4 Load Cells via PR5230 /22 Load Cell Junction Connecting up 2 to 8 Load Cells using 6-Wire Connecting Cable ..78 Connecting Load Cells with External Connecting Platforms ( ) ..80 PR5230 Instrument Manual List of Contents sartorius EN-5 5 Commissioning ..81 Data Protection/Power CAL Switch ..81 Switching on the Instrument ..82 Resetting the Instrument/Activating Network DHCP ..82 Searching the Instrument in the Network with 'Indicator Browser'..85 Operation Using a Operation Using the VNC Program ..88 System Messages during Input (VNC).

6 89 Operation Using Web Function INFO ..92 Setup Function (VNC) ..92 Setup Menu (VNC) ..93 Calibration Menu ..94 Displaying Calibration Data ..95 Selecting the Calibration Determining the Maximum Capacity [Max]..97 Determining the Scale Determining the Dead Calibration with Weight [by load]..102 Calibration with mV/V Value [by mV/V]..103 Calibration with Load Cell Data (smart calibration) ..104 Subsequent Dead Load Correction ..105 Determination Test Value/Display Test Finishing/Saving the Parameter Input ..107 Error Messages ..110 Measuring Circuit Error Messages ..110 General Error Error Messages with Ex Applications ..111 Configuring General Serial Interfaces [Serial ports].

7 112 Date and Time ..115 Operating Printing parameter ..117 Fieldbus parameter ..118 Network parameter ..120 Display Limit Values, Digital Inputs and Conditions for Limit Values and Digital Inputs, States for Outputs ..122 Configuring Digital Inputs and Configuring Limit Values ..126 Display of Limits and Digital Inputs/Outputs ..128 List of Contents PR5230 Instrument Manual EN-6 sartorius Analog Adapting the Analog Retrieve eventlog memory ..131 FatalError ..131 Setup ..132 Powerfail ..132 Backup of EAROM ..132 ConfigureIt Professional ..133 Installation ..133 Program Establish Communication to the Instrument ..137 Transfer Dataset from Instrument to PC.

8 138 Store Current Dataset on PC ..139 Store Current Dataset or Selected Parameters in the Instrument ..141 Reset the Instrument to Factory Exporting a Dataset as Printable File ..142 Operation of the Instrument via Browser (VNC)..143 Closing the 6 J-Bus/ModBus Protocol ..144 General Description ..144 ModBus-RTU ..145 ModBus- Function 1 or 2: Reading n Function 3 or 4: Reading n Successive Words ..147 Function 5: Writing a Bit ..148 Function 6: Writing a Function 8: Function 15: Writing n Successive Function 16: Writing n Successive Error Messages ..150 Word 7 SMA Protocol ..152 General ..152 Description of Used Symbols ..152 SMA Command Requesting a Controlling the Scale.

9 155 Scale Scale Data ..156 Scale Escape Command ..156 PR5230 Instrument Manual List of Contents sartorius EN-7 SMA Reply Standard Reply with Unknown Command ..158 Reply in Case of Communication Reply with Diagnosis Reply with A and B Command ..159 Scale Reply with I and N Commands ..160 Communication Error ..161 8 Asycom Protocol ..162 Commands of the Weight Other Commands ..163 SPM Error Messages for Asycom Commands ..164 9 Fieldbus Interface ..165 Fieldbus Interface Write Window (Input Area) ..166 Read Window (Output Area) ..166 Reading and Writing Description of the I/O Area (Read / Write Window) ..167 Input Output Area.

10 168 Reading and Writing Register via Fieldbus ..169 Example: Reading the Gross Fieldbus Register ..172 Register 0: IO Status Bits for Reading ..172 Register 1: Scale Register 2: State of State-Controlled Action Bits ..173 Register 4: Calibration Information, Error Byte ..173 Register 5: Device Type and Software Release ..174 Register 6: Board Register 7: (Reserved) ..174 Register 8 ..15: Weight Register 24 .. 29: Limit Values (Read/Write) ..175 Register 30, 31: Fixed Values (Read/Write) ..175 Register 80 .. 89: State-Controlled Action Bits (Write) ..175 10 Global SPM 11 Configuration print-out ..178 12 Repairs and Maintenance ..180 Battery for Date/Time.


Related search queries