Triplex Aluminum Conductor 600V URD Rev July …

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2018 Triplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 50. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. Conductors: Concentric strand or compressed 1350-H19 series Aluminum Conductor . Conductors are cabled together, with surface printing for identification.

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2018 Triplex Aluminum Conductor 600V URD The above data is nominal and …

Tags:

  Aluminum, Triplex, Conductor, 600v, Triplex aluminum conductor 600v urd

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Triplex Aluminum Conductor 600V URD Rev July …

1 1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2018 Triplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 50. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. Conductors: Concentric strand or compressed 1350-H19 series Aluminum Conductor . Conductors are cabled together, with surface printing for identification.

2 The neutral Conductor has a yellow stripe. Insulation: Black cross linked polyethylene (XLP) insulation. Standards: ASTM B-230 ASTM B-231 ASTM B-609 ASTM B-901 ICEA S-105-692 Federal Specification A-A595544A UL 854 RUS ACCEPTED Code Word Phase Conductor Neutral Single Phase Conductor (inches) Outside Diameter (inches) Weight (lbs.) per 1000 ft. Ampacity (Amps) Size AWG Stranding Insulation Thickness (mils) Size AWG Stranding Insulation Thickness (mils) Direct Burial In Duct Erskine 6 7 60 6 7/w 60 143 95 70 Vassar 4 7 60 4 7/w 60 203 125 90 Stephens 2 7 60 4 7/w 60 264 165 120 Ramapo 2 7 60 2 7/w 60 294 165 120 Brenau 1/0 19 80 2 7/w 60 408 215 160 Bergen 1/0 19 80 1/0 19/w 80 465 215 180 Converse 2/0 19 80 1 19/w 80 502 245 180 Hunter 2/0 19 80 2/0 19/w 80 560 245 180 Hollins 3/0 19 80 1/0 19/w 80 608 280 205 Sweetbriar 4/0 19 80 2/0 19/w 80 739 315 240 Monmouth 4/0 19 80 4/0 19/w 80 828 315 240 Pratt 250 37 95 3/0 19/w 80 893 345 265 Wesleyan 350 37 95 4/0 19/w 80 1166 415 320 Rider 500 37 95 350 37/w 95 1663 495 395 Fairfield 750 61 110 500 37/w 95 2289 615 525