Triplex Aluminum Conductor 600V URD Rev July 2018

1-800-945-5542 Priority Wire & Cable, little Rock, AR PWC-2018 Triplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 50. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations.

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2018 Triplex Aluminum Conductor 600V URD The above data is nominal and subject to manufacturing tolerances.

Tags:

  Little, Aluminum, Triplex, Conductor, 600v, Triplex aluminum conductor 600v urd, Triplex aluminum conductor 600v urd rev

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Triplex Aluminum Conductor 600V URD Rev July 2018

1 1-800-945-5542 Priority Wire & Cable, little Rock, AR PWC-2018 Triplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 50. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations.

2 Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. Conductors: Concentric strand or compressed 1350-H19 series Aluminum Conductor . Conductors are cabled together, with surface printing for identification. The neutral Conductor has a yellow stripe. Insulation: Black cross linked polyethylene (XLP) insulation. Standards: ASTM B-230 ASTM B-231 ASTM B-609 ASTM B-901 ICEA S-105-692 Federal Specification A-A595544A UL 854 RUS ACCEPTED Code Word Phase Conductor Neutral Single Phase Conductor (inches) Outside Diameter (inches) Weight (lbs.)

3 Per 1000 ft. Ampacity (Amps) Size AWG Stranding Insulation Thickness (mils) Size AWG Stranding Insulation Thickness (mils) Direct Burial In Duct Erskine 6 7 60 6 7/w 60 143 95 70 Vassar 4 7 60 4 7/w 60 203 125 90 Stephens 2 7 60 4 7/w 60 264 165 120 Ramapo 2 7 60 2 7/w 60 294 165 120 Brenau 1/0 19 80 2 7/w 60 408 215 160 Bergen 1/0 19 80 1/0 19/w 80 465 215 180 Converse 2/0 19 80 1 19/w 80 502 245 180 Hunter 2/0 19 80 2/0 19/w 80 560 245 180 Hollins 3/0 19 80 1/0 19/w 80 608 280 205 Sweetbriar 4/0 19 80 2/0 19/w 80 739 315 240 Monmouth 4/0 19 80 4/0 19/w 80 828 315 240 Pratt 250 37 95 3/0 19/w 80 893 345 265

4 Wesleyan 350 37 95 4/0 19/w 80 1166 415 320 Rider 500 37 95 350 37/w 95 1663 495 395 Fairfield 750 61 110 500 37/w 95 2289 615 525