Example: tourism industry

Two-line Systems

Two-line SystemsProduct CatalogueProductivity is key intoday s global lubrication increases uptime andmakes maintenance routines SystemsOur ExperienceLincoln was established in 1910and is the long-standing worldleader in grease lubrication sys-tems and equipment. Decades of business experience have provided us with a high level of expertise and know-how within the lubrication system industry. As a pioneer in the industry, we will continue being a trend-setterconfidently providing our customerswith the best lubrication systemsolutions in both price and ProductLincoln lubrication Systems reduce friction and wear; thereby,decreasing maintenance costs,improving productivity, ensuring a higher level of safety and contribution to the Servi

2 Two-line Systems Our Experience Lincoln was established in 1910 and is the long-standing world leader in grease lubrication sys-tems and equipment.

Tags:

  System, Line, Lincoln, Two line systems

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Two-line Systems

1 Two-line SystemsProduct CatalogueProductivity is key intoday s global lubrication increases uptime andmakes maintenance routines SystemsOur ExperienceLincoln was established in 1910and is the long-standing worldleader in grease lubrication sys-tems and equipment. Decades of business experience have provided us with a high level of expertise and know-how within the lubrication system industry. As a pioneer in the industry, we will continue being a trend-setterconfidently providing our customerswith the best lubrication systemsolutions in both price and ProductLincoln lubrication Systems reduce friction and wear.

2 Thereby,decreasing maintenance costs,improving productivity, ensuring a higher level of safety and contribution to the ServiceOur customer service includes the consulting, engineering andplanning of customer-orientedsystems for all applications, the manufacturing of standard components such as pumps,metering devices or control equipment, the installation andstart up of lubrication Systems on site in all parts of the world, as well as the customer training, and after-market QualityOur certified Quality ManagementSystem according to DIN EN ISO9001, our expertise, consultingqualities and inventiveness, leadthe way for future customer-orien-ted, economical and EnvironmentalManagement SystemOur Environmental ManagementSystem according to DIN EN ISO14001 and EMAS, is an integralpart of our company philosophythat reflects lincoln s future MottoKeep in motion Bleiben Sie mit uns in Bewegung!

3 CONTENTS3 Table of ContentsTwo- line SystemsSchematic Two-line Systems4 - 5 SchematicPumps6 - 12HJ 2, ZPU, ZPU Accessories Two-line Metering Devices13 - 19 VSG, VSL, VSKH, VSKV Change-over Valves20 - 22DU 1, MP-2, EM-U2 End-of- line Pressure Units23 Index24 - 264 Application Large Systems with dispersed lube points Varying lubrication quantities Ideal for rigorous conditions ( coldness)Sample applications:Large Systems using grease up to NLGI 2 IndustriesCement plants, steel mills, powerplants, mining, large machinesThe advantage of a Two-line system is that it supplies an exact metered quantity of lubricantfrom one pumpstation over metering devices are operatedby two main lines, whereby here the lubricant is simultaneously the control medium of the Two-line system can be com-bined with secondary progressivemetering devices.

4 Therebyincreasing the total number oflubrication points that are servedby a Two-line metering lincoln s high pressure capability allows small diameter tubing to be used, thereby reducing installation and material costs. Additionally, this reduces the amount of grease in the tubing which over a long period of time may deteriorate. Visual or electric monitoring of each metering device outlet pair. If a bearing clogs or a metering device outlet fails to function, all other outlet pairs will continue to function normally.

5 Simple and individual metering of lubricant. Problem-free readjustment of metered lubricant output after installation. Optimum monitoring and control possibility with a field bus system . Easy to Self-thinking SystemThe special components of a lincoln self-thinking Two-line system adjust the system to theoptimum required Two-line systemsoperate on a fixed pressure difference principle. This meansthat the change-over process is then initialized when a fixedpressure at the end of the lineshas been reached.

6 Two-line SystemsConsequently, the system alwaysoperates at a maximum the lincoln self-thinking Two-line system , the pressure isconstantly monitored and modi-fied accordingly. The systemthereby automatically regulatesthe pressure and can compen-sate for temperature adjustments of the system , even during installation,are no longer only the effective requiredpressure is generated duringeach lubrication cycle, the pumpand other system componentshave a longer service life, thesystem always operates in itsmost efficient mode and thegrease is subjected to less Two-line System5closed which causes the pressurein main line (A)

7 To rise, and ismeasured by the pressure trans-ducer. The control unit turns thepump off and signals the change-over valve to relieve main line (A). At this point half of the lubricationpoints in the system have beenlubricated. In the second half-cycle, main line (B) is pressurizedand the cycle continues as Two-line SystemA further advantage is the directdisplay of all important parame-ters on the controller. This enables full monitoring of thesystem and the of a Two-line SystemIn the first half-cycle, the lubricantis pumped into the main line (A)and the main line (B) is connectedto the relief line .

8 The lubricant,which is also the control mediumfor the system , is supplied to themetering devices. The pistons ofthe metering devices are moved into their adjusted end positions,thus dispensing an exact meteredquantity of grease. Once allmetering devices have dispensedtheir lubricant to the consumptionpoint, the system is hydraulicallyCommon ComponentspumpsHJ2 manual pumps, ZPU01/02, ZPU08/14/24with reservoir:electric pumpsfor drums:PowerMaster pneumatic pumps*, Lubrigun pneumatic pumpsmetering devices:VSG, VSL, VSKH, VSKV change-over valves.

9 DU1 pressure change-over valveEM-U2 electric change-over valveMP2 pneumatic change-over valveMHY1 hydraulic change-over valve*Not covered in this catalogue ask your lincoln representative for PumpsPart lever 1 outlet603-40558-4HJ2R-30right-hand lever 1 outlet603-40558-1HJ2AL-30 left-hand lever 2 outlets*603-40558-2HJ2AR-30 right-hand lever 2 outlets**for progressive systemsThe central lubrication pump type HJ (Helios Junior) is a manuallyoperated high-pressure pump used for the supply of grease or oil inprogressive Systems , or when equipped with one pressure line and onerelief line , for small Two-line lubrication DataHJ2HJ2 Anumber of outlets12lubricant output per lever movement2 cm3( in3)2x1 cm3(2 X in3)operating pressure300 bar (4350psi)hand force at maximum pressure300 Nsuitable lubricantsgrease up to NGLI 3outlet threaded connectionG 1/4 female (BSPP)reservoir capacity3 liters (183 in3)weight kg (19 lbs)

10 Kg ( ) lbsdimensions (L x W x H)410 x 140 x 393 mm ( x x in)AccessoriesPart valve for 6 mm tube223-13052-2check valve for 8 mm tube223-13052-3check valve for 10 mm tubeHJ2 PumpCONTENTS7 Depending on the number of pump elements, these high-pressure, high-volume pumps can be used for following applications: 1. As a supply pump for small to mid size Two-line Systems ( F version with filter block, safety valve and pressure gauge) in conjunction with a pressure-controlled change-over valve. The supply range lies within a radius of approximately 50 m from the pump depending on the ambient temperature and type of lubricant.


Related search queries