Tyc o F i r e & Building Productsis aleading manufacturer and distributor ofwater-based fire suppression systems andcomponents, offering one of the broadestlines of fire protection system expanding its capabilitiesthrough aggressive research and productdevelopment, it provides its customers effectivefire protection and construction solutions forresidential, commercial, industrial, and institu-tional buildings. tyco fire & Building Productsserves a diverse group of specifiers, includingarchitects, engineers, contractors,and associated industries with anationwide network of distri-bution and manufacturingfacilities. The introductionof new innovative Products ,technologies and productapplication extensions havepositioned the company wellfor continued growth. tyco fire & Building Productsis available worldwide under theleading brand names:CENTRAL*, GEM*, STAR*,CENTRAL* Grooved Productsand BLAZEMASTER**.

5 Breadth of Line Tyco Fire & Building Products (TFBP) offers more than 250 fire protection products and over 1,200 items used in the fabrication of

Tags:

  Product, Building, Fire, Tyco, Tyco fire amp building products

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Tyco Fire & Building Products

1 Tyc o F i r e & Building Productsis aleading manufacturer and distributor ofwater-based fire suppression systems andcomponents, offering one of the broadestlines of fire protection system expanding its capabilitiesthrough aggressive research and productdevelopment, it provides its customers effectivefire protection and construction solutions forresidential, commercial, industrial, and institu-tional buildings. tyco fire & Building Productsserves a diverse group of specifiers, includingarchitects, engineers, contractors,and associated industries with anationwide network of distri-bution and manufacturingfacilities. The introductionof new innovative Products ,technologies and productapplication extensions havepositioned the company wellfor continued growth. tyco fire & Building Productsis available worldwide under theleading brand names:CENTRAL*, GEM*, STAR*,CENTRAL* Grooved Productsand BLAZEMASTER**.

2 tyco fire & Building Productsalso offers the industry s mostcomplete fire protection softwarepackage through its SprinkCAD* SPRINKLERSSTANDARDSPRAYSPRINKLERS..6 EXTENDEDCOVERAGESPRINKLERS..10 STORAGESPRINKLERS..14 RESIDENTIALSPRINKLERS..20 DRYSPRINKLERS..22 SPECIALSPRINKLERS..24 SPRINKLERACCESSORIES..29 NOZZLES& NOZZLEACCESSORIES..31 SPRINKLER SPECIFICATIONS CHARTSSTANDARDSPRAYSPRINKLERS..34 EXTENDEDCOVERAGESPRINKLERS..36 STORAGESPRINKLERS..38 RESIDENTIALSPRINKLERS..40 DRYSPRINKLERS..40 SPECIALSPRINKLERS..42 SYSTEM VALVES & DEVICESWETSYSTEMVALVES&WATERMOTORALARM.. 44 DRYSYSTEMVALVES..46 QUICKOPENINGDEVICES..48 AIRMAINTENANCEDEVICES..49 DELUGEVALVE& DELUGESYSTEMS..50 SINGLEINTERLOCKPREACTIONSYSTEMS..51 DOUBLEINTERLOCKPREACTIONSYSTEMS..51 DELUGESYSTEMVALVES& ACCESSORIES..52 GENERALPURPOSEVALVES..54 SPECIALTYITEMS..56 PIPING & ELECTRICAL PRODUCTSSTEELPIPE& THREADEDFITTINGS.

3 58 GROOVEDPRODUCTS..59 CPVC PIPE& FITTINGS..62 ELECTRICAL..643 Escutcheon Style Reference GuideEscutcheons in this catalog are referenced by astyle number and are available in brass, chrome or white finish. Below is a visual key to distinguishindividual escutcheon styles. 4 Always refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited metric measurements throughout this catalog arebased on standard-to-metric specifications may vary from country to " " " " of LineTyco fire & Building Products (TFBP) offersmore than 250 fire protection Products andover 1,200 items used in the fabrication offire protection systems, including sprinklers,nozzles, valves, devices, CPVC, pipe fittingsand hangers, and sprinkler system and DevelopmentTFBP is backed by the largest research,design, and development group and facilitiesin the industry.

4 Our experienced staff ofengineers is continually working to developnew types of sprinklers and valves, as well asspecial hazard fire protection devices to fillpresent and future market & ApprovalsProducts offered by TFBP are listed andapproved by various fire protection productapproval laboratories and listing and approval information forthe following organizations is provided foreach product in the specification charts. Referto the application Technical Data Sheets forspecific listing and approval information. Customer ServiceTFBP distributes its manufactured productsthrough TFBP locations or independentdistributors that are strategically located toprovide our customers with the quickestdelivery possible of their complete use in CanadaUnderwritersLaboratories CanadaScientificServicesLaboratoryVerban d derSchadenversichererFactory MutualResearchCorporationLoss PreventionCouncilFMStandard Spray Sprinklersare comprised of two types of sprinklers:standard and quick response sprinklers.

5 Togetherthey offer a wide range of sprinklers from whichto choose when designing a standard coveragefire sprinkler system. Standard Response Sprinklersare intended foruse in fire sprinkler systems designed inaccordance with the standard installation rulesrecognized by the applicable Listing or Approvalagency. There are two types of standard responsesprinklers bulb type and solder TY-B bulb type sprinklers are available in avariety of attractive finishes that blend wellwith their surroundings. When in service,a small bubble in the fluid contained inthe bulb compensates for normaltemperature changes. When heated, thefluid in the bulb expands and shatters thebulb allowing water to be discharged. Series TY-L solder type sprinklers employa link whose two sections are joined bysolder with a predetermined temperaturerating.

6 Heat absorbed by the link isconducted directly to the soldered the solder melts, the link springsapart, releasing water that strikes thesprinkler Response Sprinklers are designed witha 3mm bulb or small nickel link to react morequickly at the specified temperature. They areavailable in pendent, upright, recessed,concealed, vertical sidewall, and horizontalsidewall narrow profile bulbs and attractive finishesof the Series TY-FRB provide specifiers with awide variety of sprinklers for use in quickresponse applications. The versatile QuickResponse TY-FRL Series provides the specifierwith a solder type sprinkler for mostcommercial and industrial refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited , Pendent & Recessed Pendent Standard response All hazards Solder type Discharges a hemisphericalwater spray pattern in the areaunder the sprinklerK= (80,6) K= (115,2) 1/2" (15 mm) 3/4" (20 mm) Style 20 Style 30 Brass, Chrome K Factor Thread Size Escutcheon Finish Tech DataTFP110TY-LHorizontal Sidewall Standard response Light hazard Solder type Suited for hotels, nursinghomes and hospitals Design allows piping to be confined to corridors,closets or service areasK= (80,6) 1/2" (15 mm)

7 Brass, Chrome K Factor Thread Size Finish Tech DataTFP120TY-FRLU pright, Pendent & Recessed Pendent Quick response Light hazard/ordinary hazardlight hazard K= (40,3) Solder type Typically used in hotels, motels,office buildings and othercommercial and industrialapplicationsK= (40,3) K= (80,6)K= (115,2) 1/2" (15 mm) 3/4" (20 mm) Style 20 Brass, Chrome K Factor Thread Size Escutcheon Finish Tech DataTFP130TY-FRLH orizontal Sidewal Quick response Solder type Light hazard/ordinary hazard Designed for compact instal-lation along a wall or on theside of a beam just beneath a smooth ceiling Generally used in lieu of pendent or upright sprinklers becauseof aesthetics, Building construction or economic considerationsK= (80,6) 1/2" (15 mm) Brass, Chrome K Factor Thread Size Finish Tech DataTFP140 8 Always refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited , Pendent & Recessed Pendent Standard response All hazardlight hazard K= (40,3) 5 mm bulb Discharges a hemisphericalwater spray pattern in the areaunder the sprinkler Small frame, narrow profile bulbK= (40,3) K= (80,6)K= (115,2) 1/2" (15 mm) 3/4" (20 mm)

8 Style 10 Style 40 Brass, Chrome, White K Factor Thread Size Escutcheon Finish Tech DataTFP151TY-BHorizontal, Recessed Horizontal & Vertical Sidewall Standard response Light hazard/ordinary hazard 5 mm bulb Small frame Unique deflector design of thehorizontal sidewall sprinklerresults in smaller profile Designed for installation along a wall or on the side of abeam just beneath a smooth ceiling Water discharge is directed primarily outward anddownward in a quarter spherical pattern Special deflector on the vertical sidewall sprinkler allowsit to be installed in either a pendent or upright position Sidewall sprinklers are often used in lieu of standardpendent or upright sprinklers due to buildingconstruction, economic considerations, or aestheticsK= (80,6) 1/2" (15 mm) Style 10 Brass, Chrome, White K Factor Thread Size Escutcheon Finish Tech DataTFP161 STANDARDSPRAYSPRINKLERSSTANDARDSPRAYSPRI NKLERSTY-FRBH orizontal, Recessed Horizontal Sidewall & Vertical Sidewall Quick response Light hazard/ordinary hazard 3 mm bulb Designed for use inapplications where aestheticsmust be considered or wherebuilding construction makes the installation of standardpendent or upright sprinklers impractical Vertical sidewall sprinkler can be installed in either thependent or upright position along a wall or the side of abeam and just below a smooth ceilingK= (80,6) 1/2" (15 mm) Style 10 Style 20 Brass, Chrome, White K Factor Thread Size Escutcheon Finish Tech DataTFP176TY-FRBU pright, Pendent & Recessed Pendent Quick response Light hazard/ordinary hazard light hazard K= (40,3)

9 3 mm bulb Hemispherical water spraypattern in the area under thesprinkler Small frame and narrow profilebulb enhance appearanceK= (40,3) K= (60,5) K= (80,6) K= (115,2)1/2" (15 mm) 3/4" (20 mm) Style 10 Style 20 Style 30 Style 40 Brass, Chrome, White K Factor Thread Size Escutcheon Finish Tech DataTFP171 RFII Royal Flush II Concealed Pendent Standard response/quickresponse Light hazard/ordinary hazard 5 mm bulb (standard)3 mm bulb (quick) Concealed in an enclosedescutcheon plate with flatcover for use in thoseapplications where aesthetics is aprimary consideration Separable, two-piece design of the mounting cup andcover plate allows installation of the sprinklers andpressure testing of the fire protection system prior toinstallation of a suspended ceiling or application ofthe finish coating to a fixed ceiling Internally threaded closure with 1/2" (12,7 mm) ofadjustment Available with optional dust and air sealK= (80,6) 1/2" (15 mm) Cover Plate: Chrome Plated, Brass Plated, or White Painted.

10 (Custom paint matches & colors available on request.) K Factor Thread Size Finish Tech DataTFP181 Always refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited Coverage Sprinklersare intended for the protection of areaslarger than those specified in standardinstallation rules and for specific light,ordinary, or extra hazard occupancies,where needed. Extended coveragesprinklers are available in both standardresponse (EC) and quick response (QR-EC). They are available in upright,pendent, horizontal sidewall andrecessed horizontal sidewall. Thesesprinklers are typically used in hotels,restaurants, office buildings, warehouses,and other areas where it is desirable toreduce the overall number of refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited Standard response All hazard Solder type Extended coverage area/density Deflector design expandsmaximum coverage area to 14' x 14' (4,3 m x 4,3 m)