Tyc o F i r e & Building Productsis aleading manufacturer and distributor ofwater-based fire suppression systems andcomponents, offering one of the broadestlines of fire protection system expanding its capabilitiesthrough aggressive research and productdevelopment, it provides its customers effectivefire protection and construction solutions forresidential, commercial, industrial, and institu-tional buildings. tyco fire & Building Productsserves a diverse group of specifiers, includingarchitects, engineers, contractors,and associated industries with anationwide network of distri-bution and manufacturingfacilities.

Always refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 7 STANDARD SPRAY TY-L Upright, Pendent & Recessed Pendent SPRINKLERS •Standard response •All hazards •Solder type …

Tags:

  Product, Data, Technical, Building, Fire, Response, Technical data, Tyco, Tyco fire amp building products, Upright

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Tyco Fire & Building Products

1 Tyc o F i r e & Building Productsis aleading manufacturer and distributor ofwater-based fire suppression systems andcomponents, offering one of the broadestlines of fire protection system expanding its capabilitiesthrough aggressive research and productdevelopment, it provides its customers effectivefire protection and construction solutions forresidential, commercial, industrial, and institu-tional buildings. tyco fire & Building Productsserves a diverse group of specifiers, includingarchitects, engineers, contractors,and associated industries with anationwide network of distri-bution and manufacturingfacilities.

2 The introductionof new innovative Products ,technologies and productapplication extensions havepositioned the company wellfor continued growth. tyco fire & Building Productsis available worldwide under theleading brand names:CENTRAL*, GEM*, STAR*,CENTRAL* Grooved Productsand BLAZEMASTER**. tyco fire & Building Productsalso offers the industry s mostcomplete fire protection softwarepackage through its SprinkCAD* SPRINKLERSSTANDARDSPRAYSPRINKLERS..6 EXTENDEDCOVERAGESPRINKLERS..10 STORAGESPRINKLERS..14 RESIDENTIALSPRINKLERS..20 DRYSPRINKLERS.

3 22 SPECIALSPRINKLERS..24 SPRINKLERACCESSORIES..29 NOZZLES& NOZZLEACCESSORIES..31 SPRINKLER SPECIFICATIONS CHARTSSTANDARDSPRAYSPRINKLERS..34 EXTENDEDCOVERAGESPRINKLERS..36 STORAGESPRINKLERS..38 RESIDENTIALSPRINKLERS..40 DRYSPRINKLERS..40 SPECIALSPRINKLERS..42 SYSTEM VALVES & DEVICESWETSYSTEMVALVES&WATERMOTORALARM.. 44 DRYSYSTEMVALVES..46 QUICKOPENINGDEVICES..48 AIRMAINTENANCEDEVICES..49 DELUGEVALVE& DELUGESYSTEMS..50 SINGLEINTERLOCKPREACTIONSYSTEMS..51 DOUBLEINTERLOCKPREACTIONSYSTEMS..51 DELUGESYSTEMVALVES& ACCESSORIES..52 GENERALPURPOSEVALVES.

4 54 SPECIALTYITEMS..56 PIPING & ELECTRICAL PRODUCTSSTEELPIPE& THREADEDFITTINGS..58 GROOVEDPRODUCTS..59 CPVC PIPE& FITTINGS..62 ELECTRICAL..643 Escutcheon Style Reference GuideEscutcheons in this catalog are referenced by astyle number and are available in brass, chrome or white finish. Below is a visual key to distinguishindividual escutcheon styles. 4 Always refer to the technical data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited metric measurements throughout this catalog arebased on standard-to-metric specifications may vary from country to " " " " of LineTyco fire & Building Products (TFBP)

5 Offersmore than 250 fire protection Products andover 1,200 items used in the fabrication offire protection systems, including sprinklers,nozzles, valves, devices, CPVC, pipe fittingsand hangers, and sprinkler system and DevelopmentTFBP is backed by the largest research,design, and development group and facilitiesin the industry. Our experienced staff ofengineers is continually working to developnew types of sprinklers and valves, as well asspecial hazard fire protection devices to fillpresent and future market & ApprovalsProducts offered by TFBP are listed andapproved by various fire protection productapproval laboratories and listing and approval information forthe following organizations is provided foreach product in the specification charts.

6 Referto the application technical data Sheets forspecific listing and approval information. Customer ServiceTFBP distributes its manufactured productsthrough TFBP locations or independentdistributors that are strategically located toprovide our customers with the quickestdelivery possible of their complete use in CanadaUnderwritersLaboratories CanadaScientificServicesLaboratoryVerban d derSchadenversichererFactory MutualResearchCorporationLoss PreventionCouncilFMStandard Spray Sprinklersare comprised of two types of sprinklers:standard and quick response sprinklers.

7 Togetherthey offer a wide range of sprinklers from whichto choose when designing a standard coveragefire sprinkler system. Standard response Sprinklersare intended foruse in fire sprinkler systems designed inaccordance with the standard installation rulesrecognized by the applicable Listing or Approvalagency. There are two types of standard responsesprinklers bulb type and solder TY-B bulb type sprinklers are available in avariety of attractive finishes that blend wellwith their surroundings. When in service,a small bubble in the fluid contained inthe bulb compensates for normaltemperature changes.

8 When heated, thefluid in the bulb expands and shatters thebulb allowing water to be discharged. Series TY-L solder type sprinklers employa link whose two sections are joined bysolder with a predetermined temperaturerating. Heat absorbed by the link isconducted directly to the soldered the solder melts, the link springsapart, releasing water that strikes thesprinkler response Sprinklers are designed witha 3mm bulb or small nickel link to react morequickly at the specified temperature. They areavailable in pendent, upright , recessed,concealed, vertical sidewall, and horizontalsidewall narrow profile bulbs and attractive finishesof the Series TY-FRB provide specifiers with awide variety of sprinklers for use in quickresponse applications.

9 The versatile QuickResponse TY-FRL Series provides the specifierwith a solder type sprinkler for mostcommercial and industrial refer to the technical data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited , Pendent & Recessed Pendent Standard response All hazards Solder type Discharges a hemisphericalwater spray pattern in the areaunder the sprinklerK= (80,6) K= (115,2) 1/2" (15 mm) 3/4" (20 mm) Style 20 Style 30 Brass, Chrome K Factor Thread Size Escutcheon Finish Tech DataTFP110TY-LHorizontal Sidewall Standard response Light hazard Solder type Suited for hotels, nursinghomes and hospitals Design allows piping to be confined to corridors,closets or service areasK= (80,6) 1/2" (15 mm) Brass, Chrome K Factor Thread Size Finish Tech DataTFP120TY-FRLU pright, Pendent & Recessed Pendent Quick response Light hazard/ordinary hazardlight hazard K= (40,3)

10 Solder type Typically used in hotels, motels,office buildings and othercommercial and industrialapplicationsK= (40,3) K= (80,6)K= (115,2) 1/2" (15 mm) 3/4" (20 mm) Style 20 Brass, Chrome K Factor Thread Size Escutcheon Finish Tech DataTFP130TY-FRLH orizontal Sidewal Quick response Solder type Light hazard/ordinary hazard Designed for compact instal-lation along a wall or on theside of a beam just beneath a smooth ceiling Generally used in lieu of pendent or upright sprinklers becauseof aesthetics, Building construction or economic considerationsK= (80,6) 1/2" (15 mm)