Example: air traffic controller

Typical HVAC Applications – Heating, Ventilation …

Typical hvac Applications heating , Ventilation and Air Conditioning Control Air Damper Air Filter Heater Fan Humidifier Restrictor Restrictor Air Damper Fire Damper +. M. M rP F rP %rH C rP C rP M M. Hazardous Location M M C VAV. Ordinary Location %rH. Hz PLC-System PLC-System ELEC TRIC PN. EUMATIC Redefining hvac . Electric Solutions Series Application Description Models Performance Key Features ExMax Range Hazardous locations zone 1, 2, 21, 22/Div 1, 2 (InMax for safe areas). Quarter-turn Air-dampers and Fast operating speeds (1 sec.). explosionproof actuators Torque Range 5 up to 150 Nm Quarter-turn ExMax, RedMax, InMax Universal power supply for air, fire and smoke (45 up to lbf-in). Valves Stainless steel and marine/offshore painted solutions dampers automation Easy installation ExMax+LIN & ExRun Series Hazardous locations zone 1, 2, 21, 22/Div 1, 2.

Title: Electric and Pneumatic HVAC Solutions for Damper and Valve Actuation Author: Rotork / Schischek Subject: Redifining HVAC applications with electric and pneumatic damper and valve actuated solutions from Rotork.

Tags:

  Applications, Ventilation, Hvac, Heating, Typical, Rotork, Typical hvac applications heating

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Typical HVAC Applications – Heating, Ventilation …

1 Typical hvac Applications heating , Ventilation and Air Conditioning Control Air Damper Air Filter Heater Fan Humidifier Restrictor Restrictor Air Damper Fire Damper +. M. M rP F rP %rH C rP C rP M M. Hazardous Location M M C VAV. Ordinary Location %rH. Hz PLC-System PLC-System ELEC TRIC PN. EUMATIC Redefining hvac . Electric Solutions Series Application Description Models Performance Key Features ExMax Range Hazardous locations zone 1, 2, 21, 22/Div 1, 2 (InMax for safe areas). Quarter-turn Air-dampers and Fast operating speeds (1 sec.). explosionproof actuators Torque Range 5 up to 150 Nm Quarter-turn ExMax, RedMax, InMax Universal power supply for air, fire and smoke (45 up to lbf-in). Valves Stainless steel and marine/offshore painted solutions dampers automation Easy installation ExMax+LIN & ExRun Series Hazardous locations zone 1, 2, 21, 22/Div 1, 2.

2 Linear explosionproof (InMax +LIN /InRun for safe areas). +LIN, Thrust range 500 up to N Universal power supply Linear Valves actuators for automation ExRun/RedRun/InRun (110 up to lbf). of all kind of linear valves Marine/offshore painted solutions Easy installation IQT Range Intelligent communication options with multilingual display Electric actuator for all Air-dampers and Isolating/regulating quarter-turn valve IQT125, IQT250, IQT500, Quarter-turn 50 up to Nm (37 up to lbf-in) Non-intrusive set-up Applications requiring IQT1000, IQT2000. Valves Digital, analogue or Bus Remote Control control and flexibility Self locking output CVA / CMA Range CVL-500/1000/1500/5000 Linear: Thrust range 890 up to N High performance, continuous unrestricted modulating duty S9 (CVA).

3 Control valve and CVQ-1200/2400 (200 up to lbf) Non-intrusive setup/calibration using Bluetooth wireless technology (CVA). Process control compact modulating CML-100/250/750 Rotary: Torque range 54 up to 271 Nm Comprehensive datalogging (CVA). valve and pump actuators, linear, CMQ-250/500/1000 (480 up to lbf-in) Precise control and continuous modulation (CMA). Applications quarter-turn and rotary CMR-50/100/200/89/125/250 -turn: up to 113 Nm ( lbf-in) rated Easy set-up via 6-segment LCD display and pushbutton configuration (CMA). 50/100/200/89/125/250 torque and 124 N ( lbf-in) Options: Local controls and fail-to-position rotork Power Pack (CMA). ROM/ROMpak Range Small ball valves and butterfly ROM-A/ROM-1/ROM-2,3/ Small, compact and lightweight valves, as well as Quarter-turn direct ROM-4,5&6 Torque range 35 up to 650 Nm Efficient yet simple gearing air-dampers and drive actuators ROMpak-A/ROMpak-1/ (25 up to 480 lbf-in) On - Off Ventilation ROMpak-2,3/ROMpak-4,5&6 Single-phase, three-phase and DC versions louvres Manual Solutions Series Application Description Models Performance Key Features rotork Gears 300 Range: Stainless steel.

4 300 Range Torque up to Nm (738 lbf-in). 232 Range Robust, light weight and cost-competitive quarter-turn gearboxes Air-dampers Quarter-turn worm 232 Range: Cast aluminum;. Solutions for gearboxes, valve adaption and accessories and Valves gearboxes 242 Range Torque up to Nm ( lbf-in). Suitable for hvac , fire protection and general industrial Applications FB Range 242 Range: Cast iron; Torque up to Nm ( lbf-in). Redefining Flow Control continued Pneumatic Solutions Series Application Description Models Performance Key Features GT Range Single- and double-acting pneumatic piston actuators Air-dampers Small rack and pinion Torques 2,4 up to Nm Standard 90 , 120 , 180 and 240 upon application GT - series and Valves pneumatic actuators (43 up to lbf-in) 90 position from 5 to +5.

5 2 to 10 bar air supply RC Range Single- and double-acting pneumatic piston actuators Air-dampers Small scotch yoke Torque output up to Nm Scotch yoke actuators RC200 - series and Valves actuator ( lbf-in) Optional elctro/hydraulic versions Optional manual override K-TORK Range Double-acting and spring-return configurations Air-dampers Torque outputs up to Nm Provides high torque output in a compact size Vane actuators K-TORK - series and Valves ( lbf-in) The dual-opposed lip seals eliminate all pressure-retaining o-rings in the actuator Instruments and Accessories Series Application Description Models Performance Key Features ExReg Controller System Hazardous locations zone 1, 2, 21, 22 (InReg for safe areas). Designed for use Decentralized control structures in Ex areas for hvac controller unit ExReg, RedReg, InReg 0 up to 300 Pa (VAV) Integral PID loop all gases, mists, for hazardous locations Predefined settings, predefined damper characteristics vapours and dust Stainless steel and marine/offshore painted solutions ExCos, ExBin Sensors Modulating (ExCos) and Measuring range: Hazardous locations zone 1, 2, 21, 22 (InCos /InBin for safe areas).

6 Binary (ExBin) sensor series No transducer in panel needed Modulating and for hazardous locations for ExCos, RedCos, InCos; Temperature: 40 up to +125 C ( 40 257 F) . O. No intrinsic safe circuits needed binary sensors differential pressure, ExBin, RedBin, InBin Pressure: 0 up to 100 Pa (0 0,4" wg) Actuator value indication temperature and humidity 0 up to Pa (0 20" wg) Easy parameterization control Applications Humidity: 0 up to 100 %rH Stainless steel and marine/offshore painted solutions Soldo Controls Remote electrical indication of linear valve /actuator position Actuators, valves, or in conjunction Switchboxes and Housing variants: Omega control unit combines a compact enclosure with limit SP Series, SK/SQ Series switches, visual indication and integral solenoid for position plus with a hand Control Unit Plastic, aluminium, stainless steel valve actuator control wheel or lever Enhances instrumentation and valve performance and control rotork Midland ACS: Filters, Pressure and Stainless steel Filter Regulators Specialist manufacturer of stainless steel large flow air service hvac and fire positioners and ACS: Input pressures from 0 up to 20 bar.

7 Equipment for filtration and regulation of compressed air and gases protection Landon: Free Fall Fire for the actuation industries pneumatic Regulated Pressure Range from 0,5 up to 12 bar systems Valves, Gas Safety Panels, Enhances instrumentation and valve performance and control components A Midland Company Level Control Equipment YTC E/P: YT-1000/1050 E/P, P/P: Lin. 1 2 %, Hys. 1%, Robustness Pneumatic Positioners to control P/P: YT-1200 Sens. 0,2 0,5%, Rep. 0,5% Auto calibration actuators and damper and valve Smart: YT-2500/2550, Smart: Lin. 0,5 %, Hys. 0,5 %, PID parameters control valves position YT-2600, YT-3300/3350, Sens. 0,2 %, Rep. 0,3% Communication protocols YT-3400/3450. Redefining Flow Control rotork plc Brassmill Lane Bath, UK. tel +44 1225 733200.

8 Fax +44 1225 333467. email PUB000-090-00 Issue 10/15 As part of a process of on-going product development, rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at The name rotork is a registered trademark. rotork recognises all registered trademarks. Published and produced in the UK by rotork Controls Limited. RDERGL0415.


Related search queries