Typical hvac Applications heating , Ventilation and Air Conditioning Control Air Damper Air Filter Heater Fan Humidifier Restrictor Restrictor Air Damper Fire Damper +. M. M rP F rP %rH C rP C rP M M. Hazardous Location M M C VAV. Ordinary Location %rH. Hz PLC-System PLC-System ELEC TRIC PN. EUMATIC Redefining hvac . Electric Solutions Series Application Description Models Performance Key Features ExMax Range Hazardous locations zone 1, 2, 21, 22/Div 1, 2 (InMax for safe areas). Quarter-turn Air-dampers and Fast operating speeds (1 sec.). explosionproof actuators Torque Range 5 up to 150 Nm Quarter-turn ExMax, RedMax, InMax Universal power supply for air, fire and smoke (45 up to lbf-in). Valves Stainless steel and marine/offshore painted solutions dampers automation Easy installation ExMax+LIN & ExRun Series Hazardous locations zone 1, 2, 21, 22/Div 1, 2. Linear explosionproof (InMax +LIN /InRun for safe areas). +LIN, Thrust range 500 up to N Universal power supply Linear Valves actuators for automation ExRun/RedRun/InRun (110 up to lbf).

Title: Electric and Pneumatic HVAC Solutions for Damper and Valve Actuation Author: Rotork / Schischek Subject: Redifining HVAC applications with electric and pneumatic damper and valve actuated solutions from Rotork.

Tags:

  Applications, Ventilation, Hvac, Heating, Typical, Rotork, Typical hvac applications heating

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Typical HVAC Applications – Heating, Ventilation …

1 Typical hvac Applications heating , Ventilation and Air Conditioning Control Air Damper Air Filter Heater Fan Humidifier Restrictor Restrictor Air Damper Fire Damper +. M. M rP F rP %rH C rP C rP M M. Hazardous Location M M C VAV. Ordinary Location %rH. Hz PLC-System PLC-System ELEC TRIC PN. EUMATIC Redefining hvac . Electric Solutions Series Application Description Models Performance Key Features ExMax Range Hazardous locations zone 1, 2, 21, 22/Div 1, 2 (InMax for safe areas). Quarter-turn Air-dampers and Fast operating speeds (1 sec.). explosionproof actuators Torque Range 5 up to 150 Nm Quarter-turn ExMax, RedMax, InMax Universal power supply for air, fire and smoke (45 up to lbf-in). Valves Stainless steel and marine/offshore painted solutions dampers automation Easy installation ExMax+LIN & ExRun Series Hazardous locations zone 1, 2, 21, 22/Div 1, 2. Linear explosionproof (InMax +LIN /InRun for safe areas). +LIN, Thrust range 500 up to N Universal power supply Linear Valves actuators for automation ExRun/RedRun/InRun (110 up to lbf).

2 Of all kind of linear valves Marine/offshore painted solutions Easy installation IQT Range Intelligent communication options with multilingual display Electric actuator for all Air-dampers and Isolating/regulating quarter-turn valve IQT125, IQT250, IQT500, Quarter-turn 50 up to Nm (37 up to lbf-in) Non-intrusive set-up Applications requiring IQT1000, IQT2000. Valves Digital, analogue or Bus Remote Control control and flexibility Self locking output CVA / CMA Range CVL-500/1000/1500/5000 Linear: Thrust range 890 up to N High performance, continuous unrestricted modulating duty S9 (CVA). Control valve and CVQ-1200/2400 (200 up to lbf) Non-intrusive setup/calibration using Bluetooth wireless technology (CVA). Process control compact modulating CML-100/250/750 Rotary: Torque range 54 up to 271 Nm Comprehensive datalogging (CVA). valve and pump actuators, linear, CMQ-250/500/1000 (480 up to lbf-in) Precise control and continuous modulation (CMA). Applications quarter-turn and rotary CMR-50/100/200/89/125/250 -turn: up to 113 Nm ( lbf-in) rated Easy set-up via 6-segment LCD display and pushbutton configuration (CMA).

3 50/100/200/89/125/250 torque and 124 N ( lbf-in) Options: Local controls and fail-to-position rotork Power Pack (CMA). ROM/ROMpak Range Small ball valves and butterfly ROM-A/ROM-1/ROM-2,3/ Small, compact and lightweight valves, as well as Quarter-turn direct ROM-4,5&6 Torque range 35 up to 650 Nm Efficient yet simple gearing air-dampers and drive actuators ROMpak-A/ROMpak-1/ (25 up to 480 lbf-in) On - Off Ventilation ROMpak-2,3/ROMpak-4,5&6 Single-phase, three-phase and DC versions louvres Manual Solutions Series Application Description Models Performance Key Features rotork Gears 300 Range: Stainless steel;. 300 Range Torque up to Nm (738 lbf-in). 232 Range Robust, light weight and cost-competitive quarter-turn gearboxes Air-dampers Quarter-turn worm 232 Range: Cast aluminum;. Solutions for gearboxes, valve adaption and accessories and Valves gearboxes 242 Range Torque up to Nm ( lbf-in). Suitable for hvac , fire protection and general industrial Applications FB Range 242 Range: Cast iron; Torque up to Nm ( lbf-in).

4 Redefining Flow Control continued Pneumatic Solutions Series Application Description Models Performance Key Features GT Range Single- and double-acting pneumatic piston actuators Air-dampers Small rack and pinion Torques 2,4 up to Nm Standard 90 , 120 , 180 and 240 upon application GT - series and Valves pneumatic actuators (43 up to lbf-in) 90 position from 5 to +5 . 2 to 10 bar air supply RC Range Single- and double-acting pneumatic piston actuators Air-dampers Small scotch yoke Torque output up to Nm Scotch yoke actuators RC200 - series and Valves actuator ( lbf-in) Optional elctro/hydraulic versions Optional manual override K-TORK Range Double-acting and spring-return configurations Air-dampers Torque outputs up to Nm Provides high torque output in a compact size Vane actuators K-TORK - series and Valves ( lbf-in) The dual-opposed lip seals eliminate all pressure-retaining o-rings in the actuator Instruments and Accessories Series Application Description Models Performance Key Features ExReg Controller System Hazardous locations zone 1, 2, 21, 22 (InReg for safe areas).

5 Designed for use Decentralized control structures in Ex areas for hvac controller unit ExReg, RedReg, InReg 0 up to 300 Pa (VAV) Integral PID loop all gases, mists, for hazardous locations Predefined settings, predefined damper characteristics vapours and dust Stainless steel and marine/offshore painted solutions ExCos, ExBin Sensors Modulating (ExCos) and Measuring range: Hazardous locations zone 1, 2, 21, 22 (InCos /InBin for safe areas). binary (ExBin) sensor series No transducer in panel needed Modulating and for hazardous locations for ExCos, RedCos, InCos; Temperature: 40 up to +125 C ( 40 257 F) . O. No intrinsic safe circuits needed binary sensors differential pressure, ExBin, RedBin, InBin Pressure: 0 up to 100 Pa (0 0,4" wg) Actuator value indication temperature and humidity 0 up to Pa (0 20" wg) Easy parameterization control Applications Humidity: 0 up to 100 %rH Stainless steel and marine/offshore painted solutions Soldo Controls Remote electrical indication of linear valve /actuator position Actuators, valves, or in conjunction Switchboxes and Housing variants: Omega control unit combines a compact enclosure with limit SP Series, SK/SQ Series switches, visual indication and integral solenoid for position plus with a hand Control Unit Plastic, aluminium, stainless steel valve actuator control wheel or lever Enhances instrumentation and valve performance and control rotork Midland ACS: Filters, Pressure and Stainless steel Filter Regulators Specialist manufacturer of stainless steel large flow air service hvac and fire positioners and ACS: Input pressures from 0 up to 20 bar.

6 Equipment for filtration and regulation of compressed air and gases protection Landon: Free Fall Fire for the actuation industries pneumatic Regulated Pressure Range from 0,5 up to 12 bar systems Valves, Gas Safety Panels, Enhances instrumentation and valve performance and control components A Midland Company Level Control Equipment YTC E/P: YT-1000/1050 E/P, P/P: Lin. 1 2 %, Hys. 1%, Robustness Pneumatic Positioners to control P/P: YT-1200 Sens. 0,2 0,5%, Rep. 0,5% Auto calibration actuators and damper and valve Smart: YT-2500/2550, Smart: Lin. 0,5 %, Hys. 0,5 %, PID parameters control valves position YT-2600, YT-3300/3350, Sens. 0,2 %, Rep. 0,3% Communication protocols YT-3400/3450. Redefining Flow Control rotork plc Brassmill Lane Bath, UK. tel +44 1225 733200. fax +44 1225 333467. email PUB000-090-00 Issue 10/15 As part of a process of on-going product development, rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change.

7 For the very latest version release, visit our website at The name rotork is a registered trademark. rotork recognises all registered trademarks. Published and produced in the UK by rotork Controls Limited. RDERGL0415.