Example: tourism industry

U A CS L 1.2 1 - hitachi-metals.co.jp

1. U. L.. C. S. A.. Halogen free wires .. 41. Selection guide for typical halogen free wires 3302 HF 42. 10368 AWM HF S 43. 3385 AWM HF 44. 3386 AWM HF 45. 40. PVC PE U. L.. C. S. Selection guide for typical halogen free wires A.. UL AWM CSA type . Rating temp. Rating voltage style Insulation material Insulation thickness Size range Page . V mm AWG .. 30 3302 IR-PO UL 36-20 42 .. 10368 AWM IR-PO 30-16 43. 105 300. 3385 AWM IR-PO 30-16 44. 600 3386 AWM IR-PO 28-16 45. Note 1. 1. Insulation material IR-PO IR-PO Irradiated cross-linked polyolefin PVC . Selection guide for typical halogen free wires compared with PVC wires PVC PVC . PVC wires PVC free wires PVC . Rating voltage Lead free PVC wires Halogen free wires UL No.

42 pvc・peワイヤ ハロゲンフリーワイヤ フッ素樹脂ワイヤ 液晶バックライト用高圧ワイヤ シールド線 押出リボン線 インタフェースケーブル

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of U A CS L 1.2 1 - hitachi-metals.co.jp

1 1. U. L.. C. S. A.. Halogen free wires .. 41. Selection guide for typical halogen free wires 3302 HF 42. 10368 AWM HF S 43. 3385 AWM HF 44. 3386 AWM HF 45. 40. PVC PE U. L.. C. S. Selection guide for typical halogen free wires A.. UL AWM CSA type . Rating temp. Rating voltage style Insulation material Insulation thickness Size range Page . V mm AWG .. 30 3302 IR-PO UL 36-20 42 .. 10368 AWM IR-PO 30-16 43. 105 300. 3385 AWM IR-PO 30-16 44. 600 3386 AWM IR-PO 28-16 45. Note 1. 1. Insulation material IR-PO IR-PO Irradiated cross-linked polyolefin PVC . Selection guide for typical halogen free wires compared with PVC wires PVC PVC . PVC wires PVC free wires PVC . Rating voltage Lead free PVC wires Halogen free wires UL No.

2 UL No.. UL AWM style Specification No. UL AWM style Specification No. UL1571 UL3302. 30V 80 SP23-90760B SP23-90780D. 105 . (80 ,irradiated). UL1007. 80 . SP23-90740B. UL3385 SP23-90773F. UL1430 105 . 105 SP23-90743A. (105 ,irradiated). 300V. UL1061. 80 SP23-90742B. (80 ,semi-rigid). UL10368 SP23-90988. UL3443 105 . 105 . SP23-90759A. (105 ,irradiated semi-rigid). UL1015 SP23-90741B. 105 . 600V. UL3386 SP23-90774F. UL1431 105 . 105 SP23-90770A. (105 ,irradiated). RoHS 6 RoHS 6 .. RoHS complied wires RoHS complied wires PVC . PVC free .. Halogen free . 1. RoHS;EU Restriction of the use of Certain Hazardous Substances in Electrial and Electronic Equipment . 2. RoHS 6 ; (pb) (Cd) (Hg) 6 (Cr) PBB PBDE.

3 41. U PVC PE . L.. C. S. IR-PO . A.. Halogen free flame-retardant IR-PO wire . 3302 HF. Appliance wiring material .. Rating 105 , 30V RoHS . Standard UL 758, Hitachi specification SP23-90780D.. Features 1. ,RoHS IR- 1. Halogen free flame retardant IR-PO insulation as PO RoHS complied wires. 2. 2. Small outer diameter saves space. 3. UL VW 1 3. Flammability VW-1, -F- . Application Internal wiring for electric or electronic equipment. Construction, Properties Conductor Tinned annealed copper . Insulation IR-PO Halogen free flame-retardant IR-PO . AWM E41447 STYLE 3302 26 AWG 105C VW-1 HITACHI F HF. Marking (ex.) (HITACHI-T). Conductor Insulation Unit length . Max. cond. Approx.

4 AWG . resistance mass Stranding Dia. Thick. Dia. Coil Spool Spool Spool Type at 20 kg/km . Size mm mm mm m P-5 P-10 P-30K . /km . m m m . 32 7 597 3,660 7,930 . 30 7 354 915 3,050 9,150.. 28 7 223 915 2,440 6,100. Stranded 26 7 139 915 1,830 6,100. 24 11 915 1,220 4,880. 28 7 223 915 2,440 6,100. TASC 26 7 139 915 1,830 6,100. 24 7 915 1,220 4,880. Note 1. TASC 1. TASC : Hi-wrap wire 2. 2. Electrical properties at 10M km Min. insulation resistance (at ) : 10M -km Dielectric withstanding voltage : 3. UL36 20 AWG 3. Size range : UL36 20 AWG. 4. 4. Insulation color : Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet Some stocks are available. Ordering description (ex.)

5 UL3302 1 26 AWG 7 HF UL3302 1 26 AWG (7 ) HF Coil UL3302 1 26 AWG 7 HF P-30K UL3302 1 26 AWG (7 ) HF P-30K Spool 151 Product : 151. 42. PVC PE U. L.. IR-PO C. S. Halogen free flame-retardant IR-PO wire . 10368 AWM HF S A.. Appliance wiring material .. Rating 105 , 300V RoHS . Standard UL 758, CSA . Hitachi specification SP23-90988 .. Features . 1. ,RoHS IR- 1. Halogen free flame retardant IR-PO insulation as PO RoHS complied wires. 2. 2. Small outer diameter saves space. 3. UL VW 1 CSA FT1 3. Flammability VW-1, FT1, -F- . Application Internal wiring for electric or electronic equipment. Construction, Properties Conductor Tinned annealed copper . Insulation IR-PO Halogen free flame-retardant IR-PO.

6 AWM E41447 STYLE 10368 26 AWG 105C VW-1 HITACHI F CSA AWM LL39630 I A/B 105C 300V FT1 HF. Marking (ex.) (HITACHI-T) (LL65413). Conductor Insulation Unit length . Max. cond. Approx. AWG resistance mass . Stranding Dia. Thick. Dia. Coil Spool Spool Type at 20 kg/km . Size mm mm mm /km m P-10 P-30K . m m . 30 7 354 610 3,050 7,930. 28 7 223 610 2,440 6,100. 26 7 139 610 1,830 6,100. Stranded 24 11 610 1,220 4,880. 22 17 610 1,220 3,660. 20 26 610 915 2,440. 26 7 139 610 1,830 6,100. TASC 24 7 610 1,220 4,880. 22 7 610 1,220 3,660. Note 1. TASC 1. TASC : Hi-wrap wire 2. 2. Electrical properties at 10M km Min. insulation resistance (at ) : 10M -km ,000V/1min. Dielectric withstanding voltage : ,000V/1min.

7 3. UL30 16 AWG 3. Size range : UL30 16 AWG. 4. 4. Insulation color : Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet Some stocks are available. Ordering description (ex.). UL10368 AWM 1 22 AWG 17 HF S UL10368 AWM 1 22 AWG (17 ) HF S Coil UL10368 AWM 1 22 AWG 17 HF S P-30K UL10368 AWM 1 22 AWG (17 ) HF S P-30K Spool 151 Product : 151. 43. U PVC PE . L.. C. S. IR-PO . A.. Halogen free flame-retardant IR-PO wire . 3385 AWM HF. Appliance wiring material .. Rating UL 105 , 300V CSA 105 , 300V RoHS . Standard UL 758, CSA Hitachi specification SP23-90773F.. Features 1. ,RoHS IR- 1. Halogen free flame retardant IR-PO insulation as PO RoHS complied wires. 2. UL VW 1 CSA FT1 2.

8 Flammability VW-1, FT1, -F- . Application Internal wiring for electric or electronic equipment. Construction, Properties Conductor Tinned annealed copper . Insulation IR-PO Halogen free flame-retardant IR-PO . AWM E41447 STYLE 3385 28 AWG 105C VW-1 HITACHI F CSA AWM LL39630 I A/B 105C 300V FT1 HF. Marking (ex.) (HITACHI-T) (LL65413). Conductor Insulation Unit length . Max. cond. Approx.. AWG resistance mass . Stranding Dia. Thick. Dia. Coil Spool Spool Type at 20 kg/km P-10 P-30K . Size mm mm mm /km m . m m . 28 7 223 610 1,220 3,660. 26 7 139 610 1,220 3,050. 24 11 610 915 2,440.. Stranded 22 17 610 610 1,830. 20 26 610 1,525. 18 43 305 1,220. 16 54 305 915. 26 7 139 610 1,220 3,050.

9 TASC 24 7 610 915 2,440. 22 7 610 610 1,830. Note 1. TASC 1. TASC : Hi-wrap wire 2. 2. Electrical properties at 20 10M km Min. insulation resistance (at 20 ) : 10M -km ,000V/1min. Dielectric withstanding voltage : ,000V/1min. 3. UL30 16 AWG 3. Size range : UL30 16 AWG. 4. 4. Insulation color : Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet Some stocks are available. Ordering description (ex.). UL3385 AWM 1 16 AWG 54 HF UL3385 AWM 1 16 AWG 54 HF Coil UL3385 AWM 1 16 AWG 54 HF P-30K UL3385 AWM 1 16 AWG 54 HF P-30K Spool 151 Product : 151. 44. PVC PE U. L.. IR-PO C. S. Halogen free flame-retardant IR-PO wire . 3386 AWM HF A.. Appliance wiring material .. Rating UL 105 , 600V CSA 105 , 600V RoHS.

10 Standard UL 758, CSA . Hitachi specification SP23-90774F .. Features . 1. ,RoHS IR- 1. Halogen free flame retardant IR-PO insulation as PO RoHS complied wires. 2. UL VW 1 CSA FT1 2. Flammability VW-1, FT1, -F- . Application Internal wiring for electric or electronic equipment. Construction, Properties Conductor Tinned annealed copper . Insulation IR-PO Halogen free flame-retardant IR-PO . AWM E41447 STYLE 3386 20 AWG 105C VW-1 HITACHI F CSA AWM LL39630 I A/B 105C 600V FT1 HF. Marking (ex.) (HITACHI-T) (LL65413). Conductor Insulation Unit length . Max. cond. Approx.. AWG resistance mass . Stranding Dia. Thick. Dia. Coil Spool Type at 20 kg/km P-30K . Size mm mm mm /km m . m.