Transcription of UC16PG-R Universal Programmable Controller with Relay output
1 UnitronUC ControllersUC16PG-RUCDS0032 rev cylon Controls Limited1UC16PG-R Universal Programmable Controller with Relay outputDESCRIPTIONThe UC16PG-R is a Programmable Controller , with 8 inputs and 8 x 130 x 45 mm( x x ")EnclosureInjection moulded ABSM ountingDIN railENVIRONMENTNote: This equipment is intended for field installation withinanother Temperature0% - 90% RH non-condensingAmbient Humidity0 - 50 C (32 -122 F) ImmunityEN 50082-1 EMC EmissionEN55011 Class BWIRINGT erminationPCB mounted plug terminal AreaMax: AWG 12 ( mm2)Min: AWG 22 ( mm2)Note: Use Copper or Copper Clad Aluminium conductors Requirements24 V AC +/- 20% 50/60 HzPower Rating10 VAFuse Rating2 A anti-surge (250 V AC - 2AT)PROCESSORTypeMotorola 68HC11 Clock Speed8 MHzOperating System Memory128 KUser Programmable Memory128K RAM Battery backed for 2 years minimumReal-Time ClockBattery backed for 2 years minimumINPUTS/OUTPUTSNote: Screened cable is recommended for all input Universal InputsActive voltage input: 0-10 V@ 134 KPassive input recommended sensor: PT1000 Resolution: 12 bits (with exponential filter applied to the input block in the Controller 's strategy)Note: 10k option controllers use 10k3A1 sensors onlyActive current input: 0-20 mA @ 120 (screened cable)Digital Volt Free Contact: Pulse up to 12 Hz, minimum pulse width Universal OutputsJumper selectable.
2 0 10 V DC 10mA max or 24 V AC Relay , 2 A continuous / 15 A max RS232 TTL port@ 1200, 2400, 9600, 19200 or 38400 BaudNetwork RS485 port@ 1200, 2400, 9600, 19200 or 38400 BaudKeypad port@ 9600 Baud, RJ11 socketModemModem connection supported through RS232 service portINTERFACES oftwareWN3000 software suite, Unitron Palmtop programRemote KeypadUCKRA420 Serial Text Keypad connected via RJ11 portMaximum cable length 50mSOFTWARE FEATURESM aximum number of strategy blocks255 Maximum number of Datalog Modules 16 Maximum Datalog Module capacity192 entries per DatalogMaximum Controller Address16 Note: The maximum Controller address is 8 for UC16PG-R controllers with firmware versions of or Controls LimitedClonshaugh Industrial EstateClonshaughDublin 17 IrelandTel: +353 (0) 1 2450 500 Fax: +353 (0) 1 2450 501 Email: Controls UK Limited50 Centenary Business CentreHammond CloseAttleborough FieldsNuneatonWarwickshire CV11 6 RYTel: (024) 7632 7777 Fax: (024) 7632 7878 Email: Due to cylon 's policy of continuous improvements these specifications may be upgraded without railUnitronUC ControllersUC16PG-RUCDS0032 rev cylon Controls Limited2RS485 NetworkTerminatorUniversal Input Selection JumpersUniversal output ConfigurationJumpersLegendLegendPins coveredby jumperPins openLegendNote:Outputs which are configured as Relay outputs must use terminals 13 and14 (RLY CMN) as their common Inputs and Outputs configured as Universal Outputs must useterminals 23 and 24 (CMN) as their common is because inside the UC Controller , terminals 13 and 14 (RLY CMN)are connected to the relays only, whereas terminals 23 and 24 areconnected to the Power Input's CMN line on pin 33 as shown in thisdiagram.
3 BUS3536 Volt freecontactsPIVP assiveinputPIV0-20 mAinputPIV0-10 VinputPIVPins openPins coveredby jumperUC16PG-Runitron13457628 ONDIPVIPVIPVIPVIPVIPVIPVIPVIP1 GNDCOM 9 GNDJ1 LINK1210 11 12 13 14 15 16123 745 6 83 GND45 GND67 GND8123 TerminatorINTerminatorOUTT erminatorOUTIMPORTANTE arth this Controller by connecting the CMNwire (Go), on the secondary side of the 24 V ACtransformer, to Earth at one CMNRLY CMNU/O 9+U/O10+U/O 11+U/O 12+U/O 13+U/O 14+U/O 15+U/O 16+CMNCMNCMN24V ACPower input (24v AC)Fuse"Watchdog" LED(green) Relay pack'Quick Connector'RS485 NetworkPort"Power On" LED(red)RS232 Service PortUniversal Input PortsUniversalOutput PortsKeypadPortU/I 1+CMNU/I 2+U/I 3+CMNU/I 4+U/I 5+CMNU/I 6+U/I 7+CMNU/I 8+ControllerInternalConnections13 14 15 16 17 18 19 20 21 22 23 2433 34 RLY CMNRLY CMNCMNCMNCMN24V ACControllerTerminalsNote:To avoid potential damage to controllerduring installation, it is recommended thatRLY CMN be connected to a fused 24 V VOutput321 Relay (24 V AC only)321 Pins openPins coveredby jumperLINK1 LINK1 LINK1 Address/Baud-Rate Selector SwitchSub-Network AddressThe address of the Controller on the Sub-Network is set onthese DIP switches as binary numbers as illustrated in theexamples below.
4 13457628 ONDIPSub-Network BaudRateSub-Network AddressMSBLSBB inary 0 Binary 1 Address 161342 ONMSBLSBB inary 0 Binary 15 Address 11342 ONMSBLSBB inary 0 Binary 159600 baud19200 baud38400 baud1200 baudDIP876 DIP8762400 baudDIP876 DIP876 DIP876 DIP876 DIP876 DIP876 DIP876 DIP876 Baud RateThe Baud Rate of thecontroller on the Sub-Network is set on DIPswitches 6,7, and 8.