Example: dental hygienist

UL PANEL SHOP ESTABLISHED 1969 - Nema7

UL PANEL SHOPESTABLISHED 1969 ELECTRICAL CONTROL panels & EQUIPMENTFOR ALL types OF ENVIRONMENTSA bout UsSince 1969, our team has served the electrical industry, specializing in electrical equipment for the most demanding of applications and environments. In our 30,000 square foot facility, centrally located in the oil country heartland of Tulsa, Oklahoma, we operate an NNNY/UL/CUL listed, ISO 9001:2008 PANEL shop dedicated to providing high quality customer service and expertise in NEMA 7 controls for hazardous locations is unsurpassed in the industry. We have built a team of drilled and tapped and populated cast , panelboards, purge units and other custom panels of all sizes.

ul panel shop established 1969 electrical control panels & equipment for all types of environments

Tags:

  Types, Panels, 1996, Established, Shops, Ul panel shop established 1969

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of UL PANEL SHOP ESTABLISHED 1969 - Nema7

1 UL PANEL SHOPESTABLISHED 1969 ELECTRICAL CONTROL panels & EQUIPMENTFOR ALL types OF ENVIRONMENTSA bout UsSince 1969, our team has served the electrical industry, specializing in electrical equipment for the most demanding of applications and environments. In our 30,000 square foot facility, centrally located in the oil country heartland of Tulsa, Oklahoma, we operate an NNNY/UL/CUL listed, ISO 9001:2008 PANEL shop dedicated to providing high quality customer service and expertise in NEMA 7 controls for hazardous locations is unsurpassed in the industry. We have built a team of drilled and tapped and populated cast , panelboards, purge units and other custom panels of all sizes.

2 We also provide outsourcing services for OEMs who need control panels as a part of their overall system. As Adalet s largest stocking distributor, we maintain a broad inventory of Nema7 operators, cast junction boxes, motor control and PANEL board enclosures ready for immediate customization and shipping. Our immediate access to high quality electrical distribution and control products from vendors such as Cutler Hammer & Allen Bradley also enhances our quick turn around you need customized hazardous location controls, call the experts; we can help convert your questions intoimmediate William Drotar President Walt Kosty Operations Manager Sales Inquiries FREE: PHONE: FAX: S.

3 74th E. Ave Tulsa OK re committed to providing premium services on explosion proof electrical equipment at competitive pricing, and we back our commitment with an in-stock inventory that is one of the largest in the United States. Our services include: Complete wiring and assembly of electrical components per UL standards Turn-key solutions from design to delivery, including CAD capabilities Expedited services available on in-stock itemsCONTENTSL ighting & Power Distribution Breaker 7 Fused & Non-Fused 4X Fusible & Non-Fused & Across the Line MS 2000 Manual Motor Proof Proof Control Proof Control 7 Selector 7 Pilot Lights & Push Proof Flexible Proof Control assist you with instrument housings, spin top, stainless steel, increased safety and ATEX enclosures from the Adalet product PH.

4 FAX: ANEL BOARDSPartNumberegatloVeziS xoB)B( noitpircseD)A( noitpircseDXPB121L2 Lighting PANEL 12 CircuitSingle Phase, Three Wire 225 Main Lug OnlyA120/240 XPB181L2 Lighting PANEL 18 CircuitSingle Phase, Three Wire 225 Main Lug OnlyB120/240 XPB241L2 Lighting PANEL 24 CircuitSingle Phase, Three Wire 225 Main Lug OnlyB120/240 XPB243L2 Lighting PANEL 24 CircuitThree Phase, Four Wire 225 Main Lug OnlyB120/208 XPB301L2 Lighting PANEL 30 CircuitSingle Phase, Three Wire 225 Main Lug OnlyD120/240 XPB303L2 Lighting PANEL 30 CircuitThree Phase, Four Wire 225 Main Lug OnlyD120/208 XPB361L2 Lighting PANEL 36 CircuitSingle Phase, Three Wire 225 Main Lug OnlyD120/240 XPB363L2 Lighting PANEL 36 CircuitThree Phase, Four Wire 225 Main Lug OnlyD120/208 XPBD243L2 Power Distribution PANEL 24 CircuitThree Phase, Four Wire 225 Main Lug OnlyD277/480 ENCLOSURE DIMENSIONSLIGHTING AND POWER DISTRIBUTION PANELSPartNumberDescriptionXPB1-H1 Operator for single pole BAB breakerXPB1-H2 Operator for two pole BAB breakerXPB1-H3 Operator for three pole BAB breakerXPB2-H1 Operator for 1.

5 2 or 3-pole GHB breakerBREAKER OPERATOR HANDLES*BreakerStylePartNumberVoltageSIN GLE POLEBAB 1010 - BAB 1070120/240 TWO POLEBAB 2010 - BAB 2100120/240 THREE POLEBAB 3010H - BAB 3100H240*Breakers are sold installed in panelboard onlyBRANCH CIRCUIT BREAKERS Copper free cast aluminum alloy Same housings as Adalet XCE enclosures Cutler Hammer chassis copper buss with ground & isolated neutral bars Cutler Hammer bolt-on magnetic breakers (optional adder) Spring loaded breaker handles allow closing of cover withbreaker toggle in any position (optional adder)Class I, Groups B, C & DClass II, Groups E, F & GClass IIIType 4, 7, 9 UL 50UL 1203 CSA No.

6 25 & PH: FAX: SizeFGHJKLMNW eight (lbs.)A1 3 4 2 3 13 2 160B1 3 4 2 3 352 220D24415/16215/16413/168112 285 ENCLOSURE CONDUIT DIMENSIONSCONDUIT ENTRIESBoxBox Inside DimensionsMtg Width MtgHeightOverallCoverOverallCoverOverall EachSizeWLD(A)(B)(C)(D)(E)A1616619 1120 20 11B1624619 18 20 28 11 D1634619 2720 38 10 PANELBOARD ENCLOSURE DIMENSIONSLIGHTING AND POWER DISTRIBUTION PANELSBox Size1/2 1 2 3 ATop (1) (1) Side (2) Bottom(1)(8) BTop (1) (1) Side (2) Bottom(1)(8) DTop (1) (1)Side (2) Bottom(1)(10) PH: FAX: I, Groups B*, C & DClass II, Groups E, F & GClass IIIType 4X (w/SS cover bolts)UL 1203 CSA No.

7 25 &30 EXPLOSION PROOF CIRCUIT BREAKER ENCLOSURESBREAKER FRAME STYLES Cutler Hammer thermal magnetic type circuit breakers Frame sizes range from 15 to 600 amp as follows: F Frame: 15 - 100 Amp Range JD Frame: 70 - 250 Amp Range KD Frame: 70 - 400 Amp Range LD Frame: 125 - 600 Amp Range Short circuit and overload protection must be providedby a separate protection device Available with two pole or three pole breakersStandard XBO StyleSpring loaded, compact design. Easier to assemble and less expensive. 3/4 - 14 NPSM opening required for XCBH Style Classic larger - 11 1/2 NPSM opening required for BREAKERENCLOSURESO ptional XCBH style handle shown.

8 Standard handle is FEATURES Housings are copper free aluminum alloy Furnished with stainless steel captive cover bolts For XCBA & XCBB hinge and mounting pan are optional, XCBC and larger are furnished with PH: FAX: BREAKERENCLOSURESEXPLOSION PROOF CIRCUIT BREAKER ENCLOSURES* Not a standard catalog itemAll enclosures have a 1/2 NPT on top and bottomfor installation of breather ORDER: Specify breaker trip range for your RangeFrame Size07 - 510014N-ABCX051 - 08051/0014N-BBCX052 - 07052/5224N-CBCX004 - 0520044N-DBCX008 - 0040064N-EBCX0021 - 0080084N-FBCX*CIRCUIT BREAKER ENCLOSURE ONLYE nclosurePart # Inside Nom.

9 Dimensions Overall DimensionsMounting CL to CLMtg Conduit DimensionsConduitWLDABC Lug ELug F Bolt SizeDGSize# HolesXCBA-N46 11 59 1/414 1/4 99 1/87 1/27/16 2 1/2 1 1/4 1 XCBB-N46 13 59 1/416 1/49 9 1/88 1/23/8 2 1/2 2 1 XCBC-N4 718 5 10 3/821 5/89 9 3/414 1/23/8 2 3/4 2 1/21 XCBD-N412 20 5 16 1/424 1/410 15 3/414 3/81/2 3 1/4 2 1/21 XCBE-N412246 16 1/428 1/41115 3/418 3/81/2 3 5/82 7/83 2 XCBF-N412368 16 1/440 1/413 1/215 3/429 5/8 4 1/23 3/84 2 ENCLOSURE DATA PH: FAX: 7 DISCONNECT SDisconnectPart # Inside Nom. Dimensions Overall DimensionsMounting CL to CLMtg Conduit DimensionsConduitWLDABC Lug ELug F Bolt SizeDGSize# HolesXPND30 N4 611 5 9 1/414 1/49 9 1/87 1/27/16 2 1/2 1 1/41 XPFD30 N46 11 5 9 1/414 1/49 9 1/87 1/27/16 2 1/2 1 1/41 XPND60 N46 11 5 9 1/414 1/49 9 1/87 1/27/16 2 1/2 1 1/41 XPFD60 N4 6115 9 1/414 1/49 9 1/87 1/27/16 2 1/2 1 1/41 XPND100 N4 613 5 9 1/416 1/49 9 1/88 1/23/8 2 1/2 2 1 XPFD100 N4 6135 9 1/416 1/49 9 1/88 1/23/8 2 1/2 2 1 XPND200 N47 18510 3/821 5/89 9 3/414 1/23/8 2 3/4 2 1/21 XPFD200 N41224 6 16 1/428 1/411 15 3/418 3/81/2 3 5/82 7/83 2 ENCLOSURE

10 DATA DIMENSIONSFUSIBLE & NON-FUSED DISCONNECTSFEATURES & OPTIONS Housings are copper free aluminum alloy with stainless steelcaptive cover bolts Front mounted XBO style handle, padlockable in either on or Cutler Hammer DS style toggle disconnects installed Fusible disconnects include (3) current limiting Class J fuses 400 and 600 amp range disconnects are available on special request Breather/Drains are added upon request for additional chargeNEMA 7 DISCONNECTSNEMA 7 PH: FAX: & NON-FUSED DISCONNECTSNEMA 4 XDISCONNEC TSFEATURES & OPTIONS Our disconnect switches are UL 98 rated and are fully assembled in aNEMA4X enclosure with a front operated padlockable handle.


Related search queries