Example: confidence

UL1007Hook-upWire

UL 1007 Hook-up wire 80 C 300 V. Applications: For general purpose internal wiring of electronic and electrical equipment Product Description: Tinned, stranded or solid copper conductor, 30-16 AWG. Color-coded PVC insulation. Rated temperature: 80 C. Rated voltage: 300 volts Passes UL VW-1& CSA FT1 vertical flame test. OS-1 is available Uniform thickness of wire to ensure easy stripping and cutting. Resistent to acids, oils, alkalies, moisture and fungus. Construction: Insulation Overall Conductor UL Style Conductor Standard Put-Up & Thickness Diameter Resistance at 20 C.

UL 1028 UL 1032 Hook-Up Wire 3 Applications: For internal wiring of appliances Product Description: Stranded, tinned or bare copper conductor. Color-coded PVC insulation

Tags:

  Wire, Copper, Bear, Stranded, Bare copper

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UL1007Hook-upWire

1 UL 1007 Hook-up wire 80 C 300 V. Applications: For general purpose internal wiring of electronic and electrical equipment Product Description: Tinned, stranded or solid copper conductor, 30-16 AWG. Color-coded PVC insulation. Rated temperature: 80 C. Rated voltage: 300 volts Passes UL VW-1& CSA FT1 vertical flame test. OS-1 is available Uniform thickness of wire to ensure easy stripping and cutting. Resistent to acids, oils, alkalies, moisture and fungus. Construction: Insulation Overall Conductor UL Style Conductor Standard Put-Up & Thickness Diameter Resistance at 20 C.

2 CSA Type AWG mm mm ft/coil M/coil ohm/kft 30 7 2000 610 28 7 2000 610 UL 1007 26 7 2000 610 CSA TR-64 24 11 2000 610 22 17 2000 610 ( stranded ) 20 21 2000 610 18 34 2000 610 16 26 2000 610 26 7 2000 610 24 7 2000 610 CSA TR-64. UL 1007 22 7 2000 610 20 7 2000 610 (OS-1) 18 7 2000 610 16 7 2000 610 26 1 2000 610 24 1 2000 610 UL 1007. CSA TR-64 22 1 2000 610 20 1 2000 610 (Solid) 18 1 2000 610 16 1 2000 610 1. UL 1015 Hook-up wire 105 C 600 V. Applications: For Internal wiring of appliances Product Description: Solid or stranded , tinned or bare copper conductor, 28-10 AWG.

3 Color-coded PVC insulation Rated temperature 105 C Rated voltage:600 volts. Uniform thickness of wire to ensure easy stripping and cutting. Resistant to acids, oils, alkalies, moisture and fungus Passes UL VW-1& CSA FT1 vertical flame test OS- 1 is available Construction: Insulation Overall Conductor UL Style Conductor Standard Put-Up & Thickness Diameter Resistance at 20 C. CSA Type AWG mm mm ft/coil M/coil ohm/kft 26 7 2000 610 24 11 2000 610 22 17 2000 610 UL 1015. 20 21 2000 610 CSA (TEW) 18 34 2000 610 16 26 2000 610 ( stranded ).

4 14 41 2000 610 12 65 1000 305 10 105 1000 305 UL 1015 22 7 2000 610 CSA (TEW) 20 7 2000 610 (OS-1) 18 7 2000 610 26 1 2000 610 24 1 2000 610 UL 1015 22 1 2000 610 20 1 2000 610 CSA (TEW) 18 1 2000 610 (Solid) 16 1 2000 610 14 1 2000 610 12 1 1000 305 10 1 1000 305 2. UL 1028 UL 1032 Hook-Up wire Applications: For internal wiring of appliances Product Description: stranded , tinned or bare copper conductor. Color-coded PVC insulation Rated temperature: UL 1028-105 C; UL 1032-90 C. Rated voltage: UL 1028-600 Volts; UL 1032-1000 Valts (VDC).

5 Uniform thickness of wire to ensure easy stripping and Cutting Resistant to acids, oil, alkalies moisture and fungus. Passes UL VW-1 Vertical flame test. Construction: Insulation Overall Conductor UL Style Conductor Standard Put-Up & Thickness Diameter Resistance at 20 C. CSA Type AWG mm mm ft/coil M/coil ohm/kft 22 7 1000 305 20 21 1000 305 18 34 1000 305 UL 1028. 16 26 1000 305 CSA I A 14 41 500 152 12 65 500 152 ( stranded ). 10 105 500 152 8 119 500 152 24 7 2000 610 UL 1032 22 7 2000 610 CSA I A 20 21 2000 610 18 34 2000 610 3. UL 1061 Hook - Up wire - Applications: Internal wring of computer, office equipment and other electronic & electrical equipment.

6 Product Description: Solid or stranded , tinned or bare copper conductor, 30-16 AWG. Color-coded semi-rigid PVC insulation. Rated temperature 80 C Rated voltage: 300 volts. Uniform thickness of wire to ensure easy stripping and cutting. Passes UL VW-1& CSA FT vertical flame test. Construction: Insulation Overall Conductor UL Style Conductor Standard Put-Up & Thickness Diameter Resistance at 20 C. CSA Type AWG mm mm ft/coil M/coil ohm/kft 30 7 20000 6096 28 7 20000 6096 26 7 15000 4527 UL 1061. 24 7 10000 3048 CSA I A (TEW) 22 7 10000 3048 20 7 2000 610 ( stranded ).

7 18 16 2000 610 16 26 2000 610 30 1 20000 6096 28 1 20000 3096 UL 1061 26 1 15000 4572 CSA I A 24 1 10000 3048 22 1 10000 3048 (Solid) 20 1 10000 3048 18 1 2000 610 16 1 2000 610 26 7 15000 4572 UL 1061 24 7 10000 3048 CSA I A 22 7 10000 3048 (OS-1) 20 7 2000 610 18 7 2000 610 4. UL 1095 Hook - Up wire 80 C 300 V. Applications: Internal wiring in electronic appliance. Cash register. Time-recording machines. Electronic, medical or dental equipment. Product Description: stranded or solid,tinned or bare copper conductor. Color-coded PVC insulation.

8 Uniform thickness of wire to ensure easy stripping and cutting. Rated temperature : 80 C. Rated voltage: 300 Volts. Passes VW-1 vertical flame test. Construction: Insulation Overall MAX. cond. UL Style Conductor Standard Put-Up Thickness Diameter Resistance at 20 C. AWG mm mm ft/coil M/coil ohm/km 30 7 15000 4572 28 7 15000 4572 26 7 15000 4572 UL 1095. 24 7 15000 4572 ( stranded ) 22 7 10000 3048 20 7 10000 3048 18 16 5000 1524 16 26 5000 1524 30 1 15000 4572 28 1 15000 4572 26 1 15000 4572 UL 1095 24 1 15000 4572 (Solid) 22 1 15000 4572 20 1 10000 3048 18 1 10000 3048 16 1 5000 1524 5.

9 UL 1617 UL 1618 UL 1672. Double Insulated Hook - Up wire Applications: Internal wiring of electronic and electrical equipment. Product Description: Solid or stranded , tinned copper conductor. Color-coded PVC insulation and PVC jacket. Rating : UL 1617 - 105 C, 600 V. UL 1618 - 80 C, 300 V. UL 1672 - 105 C, 300 V. Uniform thickness of wire to ensure easy stripping and cutting. Passed UL VW-1 & CSA FT1 vertical flame test. Jacket thickness : From 5 to 50 mils. Construction: Insulation Jacket Overall Standard Put-up UL Style Conductor Thickness Thickness Diameter AWG mm mm mm ft/coil M/coil 26 7 2000 610.

10 24 11 2000 610. 22 17 2000 610. UL 1617. 20 21 2000 610. CSA AWM T1 18 34 2000 610. 16 26 2000 610. ( stranded ) 14 41 2000 610. 12 65 2000 610. 10 105 2000 610. 26 7 2000 610. 24 11 2000 610. 22 17 2000 610. UL 1618 20 21 2000 610. CSA AWM T1 18 34 2000 610. 16 26 2000 610. ( stranded ). 14 41 2000 610. 12 65 2000 610. 10 105 2000 610. 24 11 2000 610. UL 1672. 22 17 2000 610. CSA AWM T1 20 21 2000 610. 18 24 2000 610. 6. UL 1571 Hook - Up wire 80 C 30 V. Applications: Internal wiring of electronic appliance Cash register Time-recording mavhing Electronic, medical or dental equipment Product Description: Solid or stranded , tinned or bare copper conductor.