Example: bachelor of science

UltraPly™ TPO Membrane - Firestone Building …

ultraply TPO Membrane 5, 10, 15, 20 Year Red Shield . Fully Adhered, Steel Deck Warranty 1. Firestone ultraply TPO Membrane 1 2. Fully Adhered with bonding adhesive 2 3. Mechanically Attached or Adhered Cover Board (Optional). 3. 4. Mechanically Attached or Adhered Insulation 4. 5. Steel Deck 5. Consult Firestone Technical Specifications, Guides and Details at Slope Requirement Deck Requirement Membrane Requirement 5. Positive slope required for warranty. Minimum 22 Gauge Steel ultraply TPO, Any Thickness Construction Type Fastener Type Seaming Requirement New construction, complete tear-off, or recover Firestone All Purpose Fastener (Max. 15 Year Firestone " Single Weld System (use robot with any wet or damaged materials removed Warranty) welder).

UltraPly™ TPO Membrane Fully Adhered, Steel Deck 5, 10, 15, 20 Year Red Shield™ Warranty 1. Firestone UltraPly™ TPO Membrane 2. Fully Adhered with Bonding Adhesive

Tags:

  Building, Adhesive, Membrane, Bonding, Ultraply tpo membrane, Ultraply, Firestone building, Firestone, Bonding adhesive

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UltraPly™ TPO Membrane - Firestone Building …

1 ultraply TPO Membrane 5, 10, 15, 20 Year Red Shield . Fully Adhered, Steel Deck Warranty 1. Firestone ultraply TPO Membrane 1 2. Fully Adhered with bonding adhesive 2 3. Mechanically Attached or Adhered Cover Board (Optional). 3. 4. Mechanically Attached or Adhered Insulation 4. 5. Steel Deck 5. Consult Firestone Technical Specifications, Guides and Details at Slope Requirement Deck Requirement Membrane Requirement 5. Positive slope required for warranty. Minimum 22 Gauge Steel ultraply TPO, Any Thickness Construction Type Fastener Type Seaming Requirement New construction, complete tear-off, or recover Firestone All Purpose Fastener (Max. 15 Year Firestone " Single Weld System (use robot with any wet or damaged materials removed Warranty) welder).

2 Joint covers are required at all joints prior to installation. Firestone Heavy Duty Fastener and at angle changes 1:12 or greater. Building Height Limitation Firestone Heavy Duty Plus Fastener Firestone Membrane adhesive Firestone HailGard Fastener (with HailGard Firestone ultraply TPO Adhered Systems ultraply bonding adhesive Composite Board or OSB only). are limited to buildings 250' ( m) or less. Single-Ply LVOC bonding adhesive Use of Air Barrier Insulation adhesive * Single-Ply LVOC bonding adhesive 1168. Firestone Twin Pack Insulation adhesive Water Based bonding adhesive (P) (Max. An air barrier is required for projects with large Firestone S Insulation adhesive 15 Year Warranty). wall openings greater than 10% of the total Firestone Fix II Insulation adhesive wall area.

3 Firestone Insulation adhesive Edge Metal System Base Tie-Ins Firestone EdgeGard System *NOTE: Max. 4' x 4' boards must be used when attaching Must be attached to substrates which provide insulation with adhesives. For direct attachment to steel deck, 6" Firestone AnchorGard System a minimum of 200 lbf (1 kN) in any direction. bead spacing must be used. Cleaning of the metal deck may Firestone Coping System be required to remove processing oils from manufacturing. Firestone Termination Bar Increased Wind Speed and Codes Firestone Aluminum Drain Bar Any wind speed coverage exceeding 55 mph adhesive Attachment (88 km/h) or projects with codes requirements Max. 15 Year Warranty: must be reviewed by a Firestone Roof Bead Spacing: F: 12", P: 12", C: 12".

4 Systems Advisor. 20 Year Warranty: Bead Spacing: F: 12", P: 6", C: 4". Full Application ( S Insulation adhesive ). Insulation Fastener and Insulation Plate Attachment Rates Field Rates for Standard 55 mph Wind Speed Insulation (Top Layer) 4' x 8' Coverboard (Optional) 4' x 8'. " to " Firestone ISO 95+ GL or RESISTA Insulation 16 " or " FiberTop Wood Fiber Board (Max. 15 Year Warranty) 16. " to " Firestone ISO 95+ GL or RESISTA Insulation 12 Firestone ISOGARD HD Cover Board 12. " to " Firestone ISO 95+ GL or RESISTA Insulation 8 " SECUROCK Gypsum-Fiber or DensDeck / (Prime) 16 16/(12). Firestone HailGard Composite Board 16 " SECUROCK Gypsum-Fiber or DensDeck / (Prime) 12 12/(10). Firestone ISOGARD HD Composite Board 8 " SECUROCK Gypsum-Fiber or DensDeck / (Prime) 8 8/(8).

5 Detail Description Firestone Termination Bar with AP Sealant applied along the caulk lip. Surface mounted or inserted counter flashing may also Wall Terminations: be used in accordance with current Firestone details. Curbs, walls, and expansion joints must be anchored with appropriate base tie-in detail, either using seam plates and fasteners or using ultraply QuickSeam Reinforced Perimeter Fastening (RPF) Strip and Batten Strip or 2" Metal Seam Plates. Curbs and Curb & Wall Flashings: walls must be flashed using minimum " ultraply TPO Membrane or ultraply TPO 18" Curb Flashing. Flashings may be sealed with welded details or QuickSeam products when acceptable. Details may include ultraply TPO Coated Metal. Corners: ultraply TPO Inside/Outside Corners or ultraply QuickSeam Corner Flashing.

6 Firestone AnchorGard or EdgeGard Fascia or Drain Bar systems. ANSI/SPRI ES-1 rated edge metal may also be used /. Roof Edges/Parapets: Firestone Coping System or ultraply TPO Coated Metal Flash with ultraply QuickSeam or ultraply Pipe Flashing (weldable), ultraply TPO Penetration Pocket, or field fabricate with Penetrations: ultraply TPO Unsupported Flashing. NOTES: 1. Only Firestone brand products are covered in a Red Shield warranty. 2. Refer to the Firestone Technical Database at for additional information regarding ultraply TPO Roof Systems. 3. Refer to the Firestone RoofGenuity tool to create roof assemblies with high-performance Firestone products at 4. DensDeck is a registered trademark of Georgia-Pacific Gypsum LLC.

7 5. It is the installing contractor's responsibility to follow applicable Building codes. 6. SECUROCK is a registered trademark of USG Firestone Building Products Company, LLC. QS-TPO-206 250 West 96th Street Indianapolis, IN 46260 Rev. 11/7/2016. Technical: 1-800-428-4511 Sales: 1-800-428-4442