Example: dental hygienist

UNDERGROUND UNDERGROUND CONNECTORS - Power …

Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)PAGE 62 NAEDNUMBER8043280433804348043580436 80438 8045380454 804558045680458804748047680478 CATALOGNUMBERUPP 2-350 UPP 3-350 UPP 4-350 UPP 5-350 UPP 6-350 UPP 8-350 UPP 3-500 UPP 4-500 UPP 5-500 UPP 6-500 UPP 8-500 UPP 4-750 UPP 6-750 UPP 8-750 PORTS2345683 456 846 8 UNDERGROUNDWIRERANGE350 MCM-#10 STR500 MCM-#10 STR750 MCM-#2 AWGW451/461/2H23/433/831/2 NAEDNUMBER803508036080370 CATALOGNUMBERUPP 1-350 UPP 1-500 UPP 1-750*L85/8913/16101/4 CTNQTY2 11 WIRE RANGE350 MCM -#10 STR500 MCM - #2 AWG750 MCM - #2 AWGDIMENSIONS (IN)W13/8233/4H23/4461/2 Direct BurialDual-Rated 600 VBLACK-BURY UNDERGROUND CONNECTORSS ubmersible for direct burial or below-grade boxesFor use in lighting, Power distribution, URDM eets ANSI and ANSI for Class A and Western UNDERGROUND Guide duty re-enterable EPDM black rubber cover with.

CTN CASE www.greaves-usa.com 11 Heritage Park, Clinton, CT 06413 • Phone 860-664-4505 • Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)

Tags:

  Power

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UNDERGROUND UNDERGROUND CONNECTORS - Power …

1 Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)PAGE 62 NAEDNUMBER8043280433804348043580436 80438 8045380454 804558045680458804748047680478 CATALOGNUMBERUPP 2-350 UPP 3-350 UPP 4-350 UPP 5-350 UPP 6-350 UPP 8-350 UPP 3-500 UPP 4-500 UPP 5-500 UPP 6-500 UPP 8-500 UPP 4-750 UPP 6-750 UPP 8-750 PORTS2345683 456 846 8 UNDERGROUNDWIRERANGE350 MCM-#10 STR500 MCM-#10 STR750 MCM-#2 AWGW451/461/2H23/433/831/2 NAEDNUMBER803508036080370 CATALOGNUMBERUPP 1-350 UPP 1-500 UPP 1-750*L85/8913/16101/4 CTNQTY2 11 WIRE RANGE350 MCM -#10 STR500 MCM - #2 AWG750 MCM - #2 AWGDIMENSIONS (IN)W13/8233/4H23/4461/2 Direct BurialDual-Rated 600 VBLACK-BURY UNDERGROUND CONNECTORSS ubmersible for direct burial or below-grade boxesFor use in lighting, Power distribution, URDM eets ANSI and ANSI for Class A and Western UNDERGROUND Guide duty re-enterable EPDM black rubber cover with.

2 125 thickness Supplied with silicone grease for ease of installation and sealingAluminum connector 6061-T6 alloy with round-bottom set screwsDual-rated CONNECTORS prefilled with oxide inhibitorSPLICE CONNECTORSUse as end-to-end splice or reducerAccommodates wide range of wire sizes within each connector sizeUPP SERIES In-lineRUS PEDESTAL CONNECTORSUse for multi-cable connections such as pedestal or URDA ccommodates a wide range of wire sizes within each connector sizeLarge heavy duty screw-cap pull-tabUPP SERIES Multi-cable* UPP1-750 has side-by-side configeration with 4 SHIPPINGWEIGHT(lbs) SHIPPINGWEIGHT(lbs)UNITDIMENSIONS (IN)UPP500 and UPP750 sizes not UL Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)NAED NUMBER80300 CATALOGNUMBERUFK 8 QUANTITY12100 UNDERGROUNDDIRECT BURIALWIRE RANGEUF jacketed copper cable #8-14 AWG2/C plus ground or 3/C plus groundDirect Burial600V CUKit ContainsConnector with 4 tubular brass splice couplers (screw type) 8-inch length of heavy-wall adhesive-lined heat-shrinkable tubing Installation instruction and wire stripping guide on package Display packaged- Card 12 X 5 X 11/2inches Installation- Use soft-flame torch or heat gun to shrink tubing and melt SERIES Splice SHIPPINGWEIGHT (lbs)

3 UNITPAGE 63UF SPLICE KIT Splice Kit for UF UNDERGROUND Feeder CableConvenient- for splice/repair of jacketed UNDERGROUND Feeder Cable UL Listed- for direct burial splicing of jacketed UF Cable #14 - 8 AWG - 2/C plus ground, or 3/C plus ground - copper wires only - 600 Volts max Faster- easier-to-use with only one piece of tubing to shrink Watertight- sealant activated with heat-shrinking process Tough- heavy-wall adhesive-lined heat-shrink Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)WIRESIZE#4#2#11/02/03/04/025030035040 05006007501000 NAEDNUMBER801008011080115801208012580130 8013580140801458015080155801608016580170 80175 CATALOGNUMBERASC 4K ASC 2K ASC 1 KASC 10 KASC 20 KASC 30 KASC 40 KASC 250 KASC 300 KASC 350 KASC 400 KASC 500 KASC 600 KASC 750 KASC 1000 KCOLORCODEG reenPinkGoldTa nOliveRubyWhiteRedBlueBrownGreenPinkBlac kYellowBrownDIEINDEX11/37512/34847129629 746717/29818/32419/47020/29922/47230024/ 473936302 SPLICECOVERR20R35R50R100 UNDERGROUNDIN-LINE WIRE SPLICE KITSWIRE RANGEMAX.

4 MCM 6 STR500 MCM 2 STRNAEDNUMBER7100571010 CATALOGNUMBERUS 350-KUS 500-KCONNECTORLENGTH (IN)333/16 Dual-Rated600 VDirect BurialSubmersible water-tight insulation splice kitsRe-enterable EPDM rubber coverEliminates taping in above-ground installationsEach splice kit contains:(1) submersible water-tight EPDM splice cover(1) capsule of silicone grease(1) electrical splice connectorSplice kit with dual-rated mechanical connectorConnector filled with oxide inhibitor and cappedUse to splice or reduce wire sizeAccepts a wide range of wire sizesDual-rated for aluminum or copper wiringUS-K SERIESS plice kit with dual-rated compression connectorConnector filled with oxide inhibitor and capped Use to splice specific wire sizeDual-rated for aluminum or copper wiringASC-K SHIPPINGWEIGHT(lbs) SHIPPINGWEIGHT(lbs)UNITPAGE Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)

5 WIRE RANGEMAX CU MAX ALMIN2/0 1/014350 30014500 400141000 10002 Submersible water-tight insulation splice kitsRe-enterable EPDM rubber coverEliminates taping in above-ground installationsEach splice kit contains:(1) submersible water-tight EPDM splice cover(1) capsule of silicone grease(1) electrical splice connectorSplice kit with copper compression connectorUse to splice specific wire size, copper wire onlyC-K SERIESNAEDNUMBER80200802058021080215 CATALOGNUMBERR 20R 35R 50R 100 SPLICE CHAMBER DIMENSIONS (IN)LENGTH watertight splice cover onlyRe-enterable EPDM rubber coverEliminates taping in above-ground installationsContains (1) submersible EPDM splice cover(1) capsule of silicone greaseR SERIESWIRESIZE#4#2#11/02/03/04/025030035 04005006007501000 NAEDNUMBER800108001580020800258003080035 8004080045800508005580060800658007080075 80080 CATALOGNUMBERC 4K C 2KC 1KC 10K C 20KC 30K C 40K C 250K C 300K C 350KC 400KC 500KC 600K C 750K C 1000 KCOLORCODEGrayBrownGreenPinkBlackOrangeP urpleYellowWhiteRedBlueBrownGreenBlackWh iteDIEINDEX8/3461011/37512/3481314 151617/29818/32419/47020/29922/47224/473 27 SPLICECOVERR20R35R50R100 UNDERGROUNDIN-LINE WIRE SPLICE KITSC opper wire only600 VRUS Approved600 VDirect BurialIN-LINE SPLICE SHIPPINGWEIGHT(lbs)UNITEST.

6 SHIPPINGWEIGHT(lbs)UNITPAGE Heritage Park, Clinton, CT 06413 Phone 860-664-4505 Fax 860-664-4546 TOLL FREE 1-800-243-1130 (Outside CT)UNDERGROUNDHEAT SHRINK TUBINGHEAVY WALL with ADHESIVEB lack cross-linked heavy-wall heat-shrink tubingUse to insulate electrical cable splices in utility/industrial applicationsUse on compression splices (C, SC, SC-FX Series) and adapters (CRK, ND-R Series)Also use to insulate barrels of compression lugsUse for insulation of primary low voltage cablesWithstands severe mechanical and sealing requirementsof URD, submersible, and direct burial installationsProvides strain relief and mechanical protectionResists impact and abrasionShrink ratio 3:1, wide range of available diametersShrink temperature: 120 CThermoplastic hot-melt adhesive liningseals to cable jackets when heatedContinuous operating temperature rating: -55 C to 110 CMeets UL 486D, CSA No.

7 , ANSI ,Western UNDERGROUND Guide Numbers and ,ICEA and NEMA insulation thickness provide 2 inch seal on each cable jacket when using long barrel compression splice. Other lengths and sizes HWA75-6 HWA100-9 HWA150-9 HWA200-9 HWA275-12 PKGQTY8 6 4 3 3 1 NOMINALSIZE1/2 3/4 1 11/22 23/4 WIRE SIZEMAX MINLENGTHPIECE (IN)6 6 9 9 9 12#6 #2 3/03505001000#8 #6 #1 2/0250600 INSIDE DIAD .75 .16 .24 .35 .47 .63 .87 HWA SERIESINSTALLATION1. Place the tube over one of the cable-ends before Install the electrical Center the tube over the splice so a minimum of 2 inches of tubing will seal to each cable With a soft-flame torch, begin at the center and heat slowly around the radius, moving progressively to eachend. When heated to shrink temperature, the tubing shrinks and conforms to the splice, and the adhesive melts and seals to the splice and cable jackets.

8 Heat so adhesive forms a bead around each end. Do not overheat, which can scorch and damage the SHIPPINGWEIGHT(lbs)UNITPAGE 66D