Understanding Potential Induced Degradation

Understanding Potential Induced Degradation Introduction Potential Induced Degradation (PID) is an undesirable property of some solar CONTENTS. modules. The factors that enable PID (voltage, heat and humidity) exist on all Introduction photovoltaic (PV) systems, but the effect does not occur on all or even most Page 1. PV systems. According to Dr. Peter Hacke of the National Renewable Energy Causes of PID. Laboratory (NREL), All c-Si [crystalline silicon] modules have elements of Page 1. reversible and non-reversible [PID] mechanisms. The key is to understand the Environmental Factors extent to which modules experience these mechanisms.

Introduction Potential Induced Degradation (PID) is an undesirable property of some solar modules. The factors that enable PID (voltage, heat and humidity) exist on all

Tags:

  Potential, Induced, Degradation, Potential induced degradation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Understanding Potential Induced Degradation

1 Understanding Potential Induced Degradation Introduction Potential Induced Degradation (PID) is an undesirable property of some solar CONTENTS. modules. The factors that enable PID (voltage, heat and humidity) exist on all Introduction photovoltaic (PV) systems, but the effect does not occur on all or even most Page 1. PV systems. According to Dr. Peter Hacke of the National Renewable Energy Causes of PID. Laboratory (NREL), All c-Si [crystalline silicon] modules have elements of Page 1. reversible and non-reversible [PID] mechanisms. The key is to understand the Environmental Factors extent to which modules experience these mechanisms.

2 Page 2. PID was first recognized in the 1970's, and has been studied since. The System Factors rapid growth in PV plant deployments, combined with dramatic reduction Page 3. in module prices (and in some cases, module quality), has brought renewed Module Factors interest in the phenomenon. And because the issue is highly technical, Page 4. requiring at least some Understanding of chemistry and physics, the renewed Cell Factors interest has been accompanied by substantial fear, uncertainty and doubt in Page 4. the market today. Effects of PID. Page 5. Although there are ways to mitigate PID, and mitigation is not always even Testing for PID.

3 Necessary, the focus of this white paper is on its causes and effects in a Page 6. PV power plant, and the status of tests for measuring PID. This discussion Conclusion provides a summary of the extensive research Advanced Energy conducted Page 7. to encourage and further education on the subject in the industry. Sources for this research are cited both in the text and in footnotes to assist anyone interested in learning more. White Paper The Causes of PID. Potential Induced Degradation , as the designation implies, occurs when the module's voltage Potential and leakage current drive ion mobility within the module between the semiconductor material and other elements of the module ( glass, mount and frame), as shown in Figure 1, thus causing the module's power output capacity to degrade.

4 The ion mobility accelerates with humidity, temperature and voltage Potential . Tests have revealed the relationship of mobility to temperature and humidity: Planar contact with the panel surface also causes a capacitive coupling to the cells, resulting in a capacitive leakage current of varying strength. 1. The PV system and environment interact to cause PID. The conditions necessary for the occurrence of PID involve (i) environmental factors, as well as factors involving (ii) the system, (iii) the module, and (iv) the cells. 2 3 While the environment is set for each individual installation, it is possible to prevent PID by properly controlling only one of the factors (ii), (iii), or (iv).

5 4 All four factors are discussed, in turn, below. Figure 1 - Leakage current and voltage Potential (negative Potential shown) cause negative (-) (purple) ions to migrate away from the semiconductor, as positive (+) (pink) ions migrate toward the semiconductor from the glass and package, and the module's external environment. Environmental Factors Because relative humidity and temperature are known to adversely affect PV plant performance in general, portions of both Underwriters Laboratories (UL) and International Electrotechnical Commission (IEC) module testing protocols involve damp heat, temperature cycling, and freeze/thaw cycling.

6 These same environmental factors also affect PID, with the Degradation being accelerated by increases in temperature and/or relative humidity. 5. It is interesting to note that while high temperatures cause an increase in the degrading effect caused by PID, high temperatures have also been shown to facilitate regeneration of the modules to reduce PID. 6. Because there is little or nothing an operator can do to change the PV plant's environment, PID is best understood and addressed by examining the system and its modules. 2. White Paper System Factors At the system level, the most significant impacts are the module's voltage Potential and sign, which depend on both the module's position in the array and the system grounding topology.

7 There are numerous considerations affecting system and inverter classification, but for the purposes of PID, the inverter(s) can be classified based on the voltage experienced by the arrays. As shown in Figure 2, four basic classifications are possible. V V. V V. VPlus VPlus + VSG + VSG. VSG VSG. VPlus VPlus + V0V. SG. + V0V. SG. VSG t VSG t VMinus VMinus - V. 0V. SG. - V. 0V. SG. t t VMinus VMinus - VSG - VSG. Symmetric, ungrounded or ground-referenced Ungrounded + AC. Symmetric, ungrounded or ground-referenced Ungrounded + AC. V V. VPlus +VSG. V VSG V. VPlus +VSG. VSG. VMinus VPlus 0V 0V. t t VMinus VSG VPlus 0V 0V.

8 T t VSG VMinus +VSG. VMinus Negative Grounding +VSG Positive Grounding Negative Figure 2 Voltage Potential depends onGrounding the grounding topology of the PV system, which Positive can have Grounding these four basic classifications. Figure 2 shows that the array voltage Potential can vary based on the grounding topology. PID is most often associated with a negative voltage Potential to ground, although issues arising from a positive reference to ground have been documented by Nevertheless, [m]any years of experience with numerous systems provide a clear and reassuring answer: for panels with crystalline solar cells, there is no interrelationship between Potential panel Degradation and the inverter principle used.

9 [1]. Additional research has revealed that, [a]n interpretation of the voltage dependency might be capacitive effects. Ionic migration caused by a certain electric force according to an applied voltage leads to a saturation of electric charge keeping all forces in thermodynamic equilibrium. These electrical charges influence the semiconducting properties [r]egardless of the voltage level itself the modules' Degradation processes stabilize on certain levels which seem to be characteristic for each module type. 8. Further research will be needed to understand the impact of higher array voltages on PID.

10 The is beginning to adopt 1000V arrays, and throughout the industry the use of 1500V and even 2000V arrays is being considered as a means of reducing system costs in large commercial and utility-scale PV plants. Resistance to PID will become increasingly critical as array voltages increase. One theory, for example, postulates that in arrays of 1500V or more, a high positive Potential is capable of causing new failure 3. White Paper Module Factors The choice of glass, encapsulation, and diffusion barriers have all been shown to have an impact on PID. For the front glass, several studies have shown sodium to exhibit a causative factor.