USPnited tructural roducts, LLC560 Wharton Circle, Suite EAtlanta, GA 30336 Phone: 404-696-8585 Fax: , LLC16"30"WALL BRACKET, HEAVY DUTYWALLBRACKET,HEAVYDUTY1" x 1-5/8" 12 GA. STRUT1"x1-5/8" *RR3"3"3"3"90o90oAABBVERTICAL TEE (DOWN)VERTICALTEE(DOWN)H*W*W*+ "H+ "20"WALL PENETRATION SLEEVEWALLPENETRATIONSLEEVELOOSE COLLAR(ADJUSTABLE)LOOSECOLLAR(ADJUSTABLE )FIXED COLLARFIXEDCOLLAR6"7/16" " *HR*90o90o90 HORIZONTAL ELBOWo90 HORIZONTALELBOWoR3"3"90o90o90 VERTICALOUTSIDE ELBOWo90 VERTICALOUTSIDEELBOWo6-1/4"5-7/8"EXPANSI ON SPLICEEXPANSIONSPLICEHORIZONTAL CROSSHORIZONTALCROSSW1W2W2W1R*ABUS6"5-7/ 8"MID-SPAN SPLICEMID-SPANSPLICEGROUND WIRE CLAMPGROUNDWIRECLAMP15"COPPER BONDING JUMPER(1600 AMP RATING)COPPERBONDINGJUMPER(1600 AMPRATING)

All USTray aluminum cable trays are classified by Underwriters Laboratories as suitable for use as equipment grounding conductors per NEC 392 and are certified by UL to meet all requirements of CSA Std. C22.2 No. 126. All NEMA and CSA safe load data is based on destruction load tests that were witnessed and certified to be

Tags:

  Suitable, Aluminum

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UNITED ALUMINUM LADDER CABLE TRAY AND CABLE …

1 USPnited tructural roducts, LLC560 Wharton Circle, Suite EAtlanta, GA 30336 Phone: 404-696-8585 Fax: , LLC16"30"WALL BRACKET, HEAVY DUTYWALLBRACKET,HEAVYDUTY1" x 1-5/8" 12 GA. STRUT1"x1-5/8" *RR3"3"3"3"90o90oAABBVERTICAL TEE (DOWN)VERTICALTEE(DOWN)H*W*W*+ "H+ "20"WALL PENETRATION SLEEVEWALLPENETRATIONSLEEVELOOSE COLLAR(ADJUSTABLE)LOOSECOLLAR(ADJUSTABLE )FIXED COLLARFIXEDCOLLAR6"7/16" " *HR*90o90o90 HORIZONTAL ELBOWo90 HORIZONTALELBOWoR3"3"90o90o90 VERTICALOUTSIDE ELBOWo90 VERTICALOUTSIDEELBOWo6-1/4"5-7/8"EXPANSI ON SPLICEEXPANSIONSPLICEHORIZONTAL CROSSHORIZONTALCROSSW1W2W2W1R*ABUS6"5-7/ 8"MID-SPAN SPLICEMID-SPANSPLICEGROUND WIRE CLAMPGROUNDWIRECLAMP15"COPPER BONDING JUMPER(1600 AMP RATING)COPPERBONDINGJUMPER(1600 AMPRATING)

2 TIN PLATEDCOPPER LUGTINPLATEDCOPPERLUG4/O COPPER CABLEGREEN INSULATION4/OCOPPERCABLEGREENINSULATIONW IDTHWIDTH+ 1-1/2"WIDTH+1-1/2" "2"9"(TYP.)9"(TYP.)HORIZONTAL SUPPORTCONNECTOR PLATEHORIZONTALSUPPORTCONNECTORPLATETRAY SPLICE PLATETRAYSPLICEPLATE3/8" FLANGED HEX NUT3/8"FLANGEDHEXNUTHOLD-DOWN CLAMP& EXPANSION GUIDEHOLD-DOWNCLAMP&EXPANSIONGUIDEI-BEAM SIDE RAILSI-BEAMSIDERAILSALUMINUM LADDER CABLE TRAY STRAIGHT SECTIONALUMINUMLADDERCABLETRAYSTRAIGHTSE CTIONROOF BLOCK " DIA. FLANGED HEX NUT " " SPRING NUTINSIDE ROOF BLOCK3/8"SPRINGNUTINSIDEROOFBLOCK3/8" HEX BOLT& FLAT WASHER3/8"HEXBOLT&FLATWASHER " DIA.

3 THREADED RODTO STRUCTURE ABOVE " " FLANGED HEX NUT3/8"FLANGEDHEXNUT3/8" ROUND-HEADSCREW WITHRIBBED NECK3/8"ROUND-HEADSCREWWITHRIBBEDNECKOPT IONAL GROUND WIRE LUG,FACTORY-WELDED TO SIDE RAILOPTIONALGROUNDWIRELUG,FACTORY-WELDED TOSIDERAILTUBULAR RUNGS, ARC-WELDED TO SIDE RAILSTUBULARRUNGS,ARC-WELDEDTOSIDERAILSW 1W2R*DROPOUT TEE WITH OUTSIDEVERTICAL RISER TAPDROPOUTTEEWITHOUTSIDEVERTICALRISERTAP RAIN HOODASSEMBLYRAINHOODASSEMBLYPRODUCT CATALOGPRODUCTCATALOGALUMINUM LADDER CABLE TRAYAND CABLE CHANNEL SYSTEMSW1 CABLE CHANNEL,VENTILATED,3" WIDE x1-3/4" DEEPCABLECHANNEL,VENTILATED,3"WIDEx1-3/4 "DEEP3"DROPOUT TEE WITH OUTSIDEVERTICAL RISER TAP6"7"ROOF BLOCK SUPPORT WITH STRUT PROFILEROOFBLOCKSUPPORTWITHSTRUTPROFILE1 CABLE TRAY STRAIGHT SECTIONS - ALUMINUMU nited tructural roducts, LLCPSP hone.

4 "4"5"6"4"5"6"7" CABLE Tray Cross-SectionStandard Laddersand Vented/TroughsSolid BottomsStrut RungsMarine Rungs(Slotted or Non-Slotted)Expanded MetalBottomsSelectfrom chartaboveA620C - 09(*) - SL20 - 24 - SCatalog Numbers for Straight Tray SectionsCableTraySystemNumberBottom TypeLength102024253040- 10'-0 - 20'-0 - 24'-0 - 25'-0 - 30'-0"- 40'-0 12- 12'-0"Width06091218243036-6"-9"- 12"- 18"- 24"- 30"- 36"060912VT- 6" Rung Spacing- 9" Rung Spacing- 12" Rung Spacing- Ventilated/TroughSFSFU- Solid Flat Bottom- Solid Flat Bottom,Non-standard lengthsand widths areavailable.

5 Consultfactory for lead timesItemCodeStraightLengthExample:SLHar dwareFinish- GeometPlatedSteelGS- StainlessSteel 316 Optional Rungsand BottomsInsert 2-Digit(See Below)to specifyoptional rungsand bottomsBottom CodeUnderRungsBLANK- SAFE LOADLOAD - in2100012'12B81 lbs/ft - 12' in2100012', 24 12CD-3M A412C1100 lbs/ft - 12' in2160012 , 20'20A58 lbs/ft - 20' spanD-6M in2160020', 24 20B85 lbs/ft - 20' spanE-6M in2120012'12B78 lbs/ft - 12' in2160012 , 20'20A57 lbs/ft - 20' spanD-6M in2160020'20C115 lbs/ft - 20' spanE-6M in2120012'12B89 lbs/ft - 12' in2120012'12C105 lbs/ft - 12' in2160012 , 20'20A62 lbs/ft - 20' spanD-6M in2160020', 24 20B80 lbs/ft - 20' spanE-6M in2200012 , 20.

6 24'20C109 lbs/ft - 20' spanE-6M in2200020', 24 20C+ 104 lbs/ft - 24' spanE-6M in2200020', 25 20C++ 128 lbs/ft - 25' spanE-6M in2120012'12C100 lbs/ft - 12' spanD-3M in2200020', 24 20C108 lbs/ft - 20' spanE-6M in2200020', 25 20C+ 111 lbs/ft - 24' spanE-6M in2200020 , 30'20C++ 105 lbs/ft - 30' spanE-6M in2200030', 40 20C++ 114 lbs/ft - 40' spanE-6M A820E4A847"8"SIDERAILHEIGHTLOADDEPTHAll USTray ALUMINUM CABLE trays areclassified by Underwriters Laboratoriesas suitable for use as equipmentgrounding conductors per NEC 392and are certified by UL to meet allrequirements of CSA Std.

7 All NEMA and CSA safe load datais based on destruction load tests thatwere witnessed and certified to beaccurate by Underwriters " Square tubular rungs6 , 9 , 12 Rung spacings5 Rung spacing for troughsRungs have large radius cornersOptional rung designs availableSolid, flat sheet on top ofladder rungs on 12 centersBottoms can be located under rungsBottoms can be located on top ofand under rungs (double bottom)Heavier bottoms availableStrut profile accepts standardspring nuts with short springs foradded CABLE clamping optionsHeavy-duty for extreme loadsExtra wide 1-5/8 CABLE supportStandard rung for 8 high traysHat-shaped rungs have round slots on 1 centersAccommodates stainless steelbanding in marine applicationsExtra Wide 1-3/4 CABLE supportCan be provided without slots1 Expanded, flattenedaluminum sheet under x 1 Bottom openingsBlocks birds, rodents, vandalsMaintains open-air.

8 LADDER ratingRUNG ORIENTATIONSASDSUBOTTOMCODESLOTS ALTERNATEFACING UP/DOWNSLOTS FACE DOWNSLOTS FACE UPRUNG DESIGNMRHRBOTTOMCODEMARINE RUNG(WITH SLOTS)HAT RUNG(NO SLOTS)BOTTOM DESIGNEMBOTTOMCODE1 EXPANDEDMETAL UNDERLADDER RUNGSE xtruded ALUMINUM alloy 6063-T6 Side rails are I-Beam profilesRungs are 1-1/8" square tubeswith open slot facing downArc-welded Classified Certified load capacitiesNEMA, CSA and NEC CompliantNecessary Splice Plates withhardware are included with allstraight sections and fittingsMade in the USA RUNG SPACING060912 VTBOTTOMTYPE6 RUNG SPACING5 RUNG SPACING12 RUNG SPACING9 RUNG SPACINGBOTTOM LOCATIONSFSFUSFDBOTTOMTYPESOLID FLAT BOTTOMON TOP OF RUNGSSOLID FLAT BOTTOMUNDER RUNGSBOTTOMS ON TOPAND UNDER RUNGS2 CABLE TRAY STRAIGHT SECTIONS - ALUMINUMU nited tructural roducts, LLCPSP hone.

9 "4"5"6"4"5"6"7"SIDERAILHEIGHTLOADDEPTHCS ALOADCLASSSYSTEMNUMBERSAFE LOAD DATA (Lbs/Ft Uniformly Distributed, Safety Factor)68101214161820222425262830354012 BCA412B3241821178112CD-3M A412C40022514410020AD-6M A420A64436323216111890725820BE-6M A420B6495313402361731321058512 BCA512B3121761127820AD-6M A520A63335622815811689705720CE-6M A520C64964946031923417914211512BA612B356 20012889D-3M12CA612C420236151105D-3M20AD -6M A620A64938724817212696776220BE-6M A620B649500320222163125998020CE-6M A620C64964943630322217013510920C+E-6M A624C6496496004163062341851501241049620C ++E-6M A620D64964964955540831324720016513912812 CD-3M A712C40022514410020CE-6M

10 A720C64964943230022016913310820C+E-6M A720D64964963944432624919716113211120C++ E-6M A720E64964964964948236929123619516415113 912010520C++E-6M A820E80080080080080071256245637631629226 92322031491147"8"SUPPORT SPAN (feet)NEMA AND CSA SPAN/LOAD CLASSESSpan/Load Class Designations:Concentrated Static Loads:Example:Commonly called the Load Class, this definesthe load-carrying capability of the tray for a specific support span should be selectedthat reflects the actual total working load and support span for each and cost of the CABLE tray is greatly affected by this designation.