The Door Entry Controller System dramatically expandsthe potential installation sites for door Phone speakers. Inaddition, the Door Entry Controller provides two TouchTone controlled relays to operate door strikes or Phone speakers can be used on single line, resi-dential or home office applications as well as on fullyloaded systems, because they are no longer limited toinstallation on unused trunk ports. Universal connection to door Phone System limited to ground/loop start trunk connection May be used with door phones, PABX systems, Electronic key systems, 1A2 Key systems or single line telephones Custom ringing mode distinguishes door Phone calls from calls Call waiting tones indicate which door phoneis calling and distinguish a door Phone callfrom a line call Calls can be placed on hold when visitors call from the door Phone Provides two Touch Tone controlled and dry contact closures for door strikes or gate openers Allows two door phones to share a single telephone line with a residential or business telephone System Built-in talk battery for no

C. Optional Connection: Adding Paging* to Homes and Small Businesses The Door Entry Controllercan be used to control a paging amplifier and a door phone speaker (or second amplifier) from a single phone line. The amplifier used, must provide talk battery.

Tags:

  System, Doors, Universal, Phone, Universal door phone system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Universal Door Phone System - Paging Solutions

1 The Door Entry Controller System dramatically expandsthe potential installation sites for door Phone speakers. Inaddition, the Door Entry Controller provides two TouchTone controlled relays to operate door strikes or Phone speakers can be used on single line, resi-dential or home office applications as well as on fullyloaded systems, because they are no longer limited toinstallation on unused trunk ports. Universal connection to door Phone System limited to ground/loop start trunk connection May be used with door phones, PABX systems, Electronic key systems, 1A2 Key systems or single line telephones Custom ringing mode distinguishes door Phone calls from calls Call waiting tones indicate which door phoneis calling and distinguish a door Phone callfrom a line call Calls can be placed on hold when visitors call from the door Phone Provides two Touch Tone controlled and dry contact closures for door strikes or gate openers Allows two door phones to share a single telephone line with a residential or business telephone System Built-in talk battery for no applications Auxiliary contact output for doorbells, cameras, etc.

2 Compatible with pulse or Touch Tone phonesPower: 120V AC , UL listed adapter providedDimensions: 133mm x 89mm x 44mm ( " x " x ") Shipping Weight: kg (2 lb)Environmental: 0 C to 32 C (32 F to 90 F) with 5% to 95%non-condensing humidityDoor Strike Relay Contacts: 5A @ 30V DC/250V AC maximumAuxiliary Relay Contacts:.5A @ 125V AC, 1A @ 30V ACConnections: (2) RJ11 jacks, (1) 12 position terminal blockPulse Dialing Detection: 10 pps Talk Battery: 30V DCMaximum Door Phone Speaker Power Supply Length: 100 ft,24 awg wireSSppeecciiffiiccaattiioonnss Provide commercial or residential security via two-way handsfree communication from a door or gate Add one or two door Phone speakers to your home or office phones Open door or gate remotelyAApppplliiccaattiioonnssFFeeaatt uurreessUUnniivveerrssaallDDoooorrPPhhoo nneeSSyysstteemmMaterial Code/Comcode # 408466563 (controller) and # 408466548 (speaker)Add Door Phones to Your Phone SystemPEC # Standard Connection.

3 Connecting Door Phone Speakers with or without a LineDOOR ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 111212orStandard Analog PhonesBack View of LUUDS Door Phone SpeakerBack View of LUUDS Door Phone SpeakerUnused Trunk Input of PABX/KSUTalk Battery SwitchOFFONN ormally OpenNormally ClosedNote: See Programming section to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC maximumOutput to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC AC Adapter included 120V Line or Analog PABX/KSU station(Sharing a Line)(No Line)The Door Entry Controllercan be used without a line.

4 This is ideal for connecting the Door Entry Controllerto an unused trunk/line input of your Phone System or connecting to phones used only for door Phone speaker Optional Connection: Connecting an LUADS Analog Door Phone Speaker to a Station PortDOOR ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 111212 Talk Battery Adapter included120V ACAnalog PABX/KSU stationOutput to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC maximumLUADS Analog Door Phone SpeakerThis application is ideal for connecting the Door Entry Controllerto an unused analog station of your Phone Programmingsection Gand Operationsection A.

5 Important:In this application, only a single door Phone isused and 5must be selected when in Optional Connection: Adding Paging * to Homes and Small BusinessesThe Door Entry Controllercan be used to control a Paging amplifier and a door Phone speaker (or second amplifier)from a single Phone line. The amplifier used, must provide talk battery. Note:The Door Entry Controllermust beprogrammed to be in the Paging Mode(see Programming).DOOR ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 111212orStandard Analog PhonesUnused Trunk Input of PABX/KSUTalk Battery SwitchOFFONN ormally OpenNormally ClosedNote: See Programming section Line or Analog PABX/KSU stationOutput to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC AC Adapter included 120V ACBack View of LUUDS Door Phone SpeakerPaging Amplifier that provides Talk 24V DC Doorbell (see Programming Features)D.

6 Optional Connection: One or Two Door Phones Sharing a Single Line with House PhonesDOOR ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 111212 Standard Analog PhonesBack View of LUUDS Door Phone SpeakerBack View of LUUDS Door Phone SpeakerTalk Battery SwitchOFFONN ormally OpenNormally ClosedNote: See Programming section Line or Analog PABX/KSU stationOutput to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC maximumOutput to Doorstrike/Magnetic Lock/Gate Controller (not included) with power supply not to exceed 5 Amp @ 250V AC maximum 5 Amp @ 30V DC AC Adapter included 120V AC* Note: Requires a pagingamplifier that provides Accessing the Programming Mode1.

7 Accessing the Programming Mode Locally (Security Code Bypass Mode)a. Move DIP switch 2 from OFF to ON (see Programmingsection A). into the Door Entry Controller from a Touch Tone Phone . Note:Call in from another line to avoid busy signals, Answer the call using the device on the PHONES double beep will indicate that you have accessed the programming mode. can now Touch Tone program the features listed in section finished programming, move DIP switch 2 to the OFF : Programming from a cell- Phone may not be suitable in areas with weak Accessing the Programming Mode into the Door Entry Controllerfrom a Touch Tone Phone . Note:Call in from another line to avoid busy signals, Answer the call using the device on the PHONES either Phone enter followed by the six digit security code (see Programmingsection F).

8 Double beep will indicate that you have accessed the programming mode. can now Touch Tone program the features listed in section : Programming from a cell- Phone may not be suitable in areas with weak #0111 #0312 #03 2 Programming the Door Entry set door strike 1 to activate for 3 set the auxiliary contacts to activate a camera while either door Phone speaker is set the auxiliary contacts to activate an external ringer or strobe light in a custom ring cadencewhile either door Phone speaker is ringing4..to have door Phone speakers ring phones in a custom ring patternD. Programming ExamplesB. Contact SelectionSelection shunts are provided for each door strike relayand the auxiliary relay. Place the shunt in the left posi-tion for normally open contacts, or in the right positionfor normally closed contacts.

9 These shunts are locateddirectly above the terminal block positions that ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 111212 Normally OpenNormally ClosedPPrrooggrraammmmiinnggSwitch123A. Dip Switch ProgrammingDescriptionDoorstrikeActivati on TimeSecurity CodeBypass ModeModeSelectionOperationOFF- .5 seconds (factory setting)ON- 10 secondsOFF- Normal Mode (factory setting)ON- Security Code Bypass ModeOFF- Line Concentrator ModeON- Normal Operation (factory setting)DOOR ENTRY/PAGINGCONTROLLERPOWER ACLINE INPHONESSTATUSAUX. CONTACTOUTPUTDOOR STRIKE 1 DOORBOX 1 DOOR BOXPOWERDOORBOX 2 DOORSTRIKE 23 4 5 6 7 8 9 10 1112121 2 3 Dip SwitchesON OFFA luminum Box(included)Large foam rubber gasket (included)Designed to be flush mounted to the includ-ed x x 2 deep aluminum :Must use new box.

10 Do NOTuse boxfrom previous PARTNER Door Quick Programming FeaturesDoor strike 1 activation time .5 - 10 seconds (see Note below) ..Door strike 2 activation time .5 - 10 seconds (see Note below) ..Auxiliary contact activation time .5 - 10 seconds (see Note below) ..Note: 00= .5seconds, 01-10= 1-10seconds, factory set to 00(.5seconds).Auxiliary contact latched while either door Phone speaker is activated ..Auxiliary contact activated in custom ring cadence ..Security Code (factory set to 845464) ..Disable all special modes listed below (factory default) ..Doorbell mode ..Custom ring mode ..Multiple relay activation mode .. Paging mode ..Emergency Phone mode ..Inhibit latching commands mode ..To reset to factory settings ..Note: Multiple modes may be digits (00-10)2 digits(00-10)2 digits(00-10)11126 digits(0-9) 0 1 2 3 4 5 6###++++++#01#02#03#03#03#47 MemoryLocationEnter Digits- then -Enter DigitsG.