Example: marketing

UNWRAPPED - viadux.com.au

VIADUX VERSION ACTIVE CORROSION PROTECTIONELIMINATING THE NEED FOR polyethylene SLEEVING UNWRAPPEDDUCTILE IRON PIPEELIMINATING THE NEED FOR SLEEVINGZINALIUM ACTIVE CORROSION PROTECTIONFACTORY APPLIED ZINC ALUMINIUM ALLOY COATING SYSTEMSYNTHETIC RESIN PORE SEALERThe outer blue coating is a synthetic resin pore sealer applied at an average thickness of 100 m, the particles 'agglomerated' in a way to form a uniform, stable and adhesive protective film, resistant to atmospheric conditions (stockyards) and to the mechanical and chemical properties are compatible with the increased resistance of the ZnAl IRONThe Ductile Iron shell is manufactured to AS 2280 giving complete compatibility with current water industry standards and by PAM, the worlds leading manufacturer of DI pipe , Zinalium is a highly effective, patented alloy comprising of 85% zinc and 15% aluminium.

viadux version 1.1 zinalium ® active corrosion protection eliminating the need for polyethylene sleeving unwrapped ductile iron pipe

Tags:

  Pipe, Polyethylene, Unwrapped

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of UNWRAPPED - viadux.com.au

1 VIADUX VERSION ACTIVE CORROSION PROTECTIONELIMINATING THE NEED FOR polyethylene SLEEVING UNWRAPPEDDUCTILE IRON PIPEELIMINATING THE NEED FOR SLEEVINGZINALIUM ACTIVE CORROSION PROTECTIONFACTORY APPLIED ZINC ALUMINIUM ALLOY COATING SYSTEMSYNTHETIC RESIN PORE SEALERThe outer blue coating is a synthetic resin pore sealer applied at an average thickness of 100 m, the particles 'agglomerated' in a way to form a uniform, stable and adhesive protective film, resistant to atmospheric conditions (stockyards) and to the mechanical and chemical properties are compatible with the increased resistance of the ZnAl IRONThe Ductile Iron shell is manufactured to AS 2280 giving complete compatibility with current water industry standards and by PAM, the worlds leading manufacturer of DI pipe , Zinalium is a highly effective, patented alloy comprising of 85% zinc and 15% aluminium.

2 This factory applied, ACTIVE corrosion protection system, will extend the service life of your pipeline and reduce on-site handling by eliminating the requirement for polyethylene ZINC/ALUMINIUM ALLOYThe entire outer surface of the ductile iron pipe is coated in an 85% zinc and 15% aluminium alloy at a density of 400g per m2. This hot metal spray is applied directly onto the ductile iron providing active galvanic PAM patented ZnAl alloy applied at twice the density of standard zinc LAYER OF ZINC-ALUMINIUM 85/15 ALLOY WITH A MINIMUM DENSITY OF 400g/m2A PROTECTIVE LAYER OF SYNTHETIC RESIN 100 mDUCTILE IRON2 ZINALIUM ACTIVE CORROSION PROTECTIONPORE SEALERZnAl ALLOYDUCTILE IRONZnAlIMPROVING EFFICIENCIES WITH FASTER, EASIER DI pipe INSTALLATIONZINALIUM ACTIVE CORROSION PROTECTION 3 The factory applied, ACTIVE corrosion protection system removes the risks associated with installation of sleeving, as it is no longer required.

3 In addition, Zinalium will ACTIVELY protect the underlying iron against scratches and scrapes which can commonly occur during transport and , EASIER INSTALLATIONE xtensive research in the installation of loose polyethylene sleeving reveals that it takes up to 15 minutes per length of pipe to install. This accumulated time can account for up to 5% of the cost of a pipeline, tying up personnel and eliminating the need for sleeving, the installation of Ductile Iron pipe becomes a simple one step push fit operation. ALUMINIUM, WORKING WITH ZINCThe perfect combination of aluminium and zinc in the ZnAl alloy considerably increases the strength of the protective properties of the outer high quality zinc hydroxide layer can only form when the zinc transforms at an appropriate rate.

4 In Zinalium , this change is optimised by two factors:- the porous paint layer is applied at an optimum thickness to allow both the formation of zinc hydroxides and the ongoing galvanic effect;- the presence of aluminium slows the transformation effect to allow the creation of a more stable protective layer compared to zinc alone, whilst allowing the sacrificial galvanic healing process to take COSTNot only will contractors find a typical ~5% cost saving in time, but also further saving in the cost of the sleeving itself which makes up to 2% of the cost of Ductile Iron pipe as a complete end result is a cost effective solution which will increase installation efficiency and asset life.

5 THE ACTIVE PROPERTIES OF ZINCThe Zinalium coating system benefits from the 'active' properties of the Zinc-Aluminium alloy when in contact with the soil in that it:- provides a long term barrier by forming a stable all-round protective layer (zinc hydroxides) covering the entire surface of the buried pipe ;- restores the protective layer at points where it has been slightly damaged (impacts during transportation, scrapes when backfilling) through the galvanic effect between the exposed iron and the zinc around the coated in PAM s patented Zinalium alloy may be buried in contact with the majority of soils, except:- Acidic peaty soils;- Soils below the marine water table with a resistivity lower than 500 delivers savings in installation time and overall TYTONHYDROCLASS ZINALIUM SYSTEMLINING OPTIONSHYDROLINE-C is a centrifugally spun cement mortar lining made up of Type SR (Sulphate Resisting) Blast Furnace Slag cement standard internal is HYDROLINE-C with an added Seal Coat to inhibit the leaching of lime where very aggressive, soft waters of low hardness (total alkalinity <30mg/L) or high dissolved C02 are being conveyedTECHNICAL DATAS izes DN 100 - DN 750 Certification TYTONHYDROCLASS pipes are certified to.

6 - AS/NZS 2280 Ductile iron pipes and fittings- AS 4020 Testing of products for use in contact with drinking waterEnd Connections TYTON push-on rubber ring joint. TYTON-LOK gaskets are also available for restrained joints up to DN 375 rated to PN 16 External Coating Zinalium ZnAl alloy 400g per m2 Blue synthetic resin 100 m4 ZINALIUM ACTIVE CORROSION PROTECTIONTYTONHYDROCLASSFOR POTABLE, RECYCLED & RAW WATERMANUFACTURED TO AS 2280 FOR THE AUSTRALIAN WATER INDUSTRY. DN 100 - DN 750 TYTONHYDROCLASS Ductile Iron pipe , with Zinalium external protection, reflects state-of-the-art manufacture in evolving water industry in pressure classes, PN 20 and PN 35, TYTONHYDROCLASS becomes the first class choice for efficiency gains and cost savings without sacrificing the time proven superior performance capabilities associated with Ductile Iron pipeline with the time proven, robust TYTON JOINT which provides flexibility, ease of installation and is your guarantee of delivers with.

7 Increased bores giving increased flows and reduced head losses result in lower pumping costs Faster laying with no sleeving required, increased efficiency, and reduced cost means more savings Active corrosion protection with 400g per m2 ZnAl Alloy Zinalium gives a longer lasting flows and reduced head losses for lower pumping costs. No sleeving MORTARDUCTILE IRONZINC-ALUMINIUM ALLOYPORE SEALER 100 mPORE SEALER 100 mZINC RICH PAINTTHE TYTONINTEGRAL ZINALIUM SYSTEMLINING OPTIONSHYDROLINE-CA calcium aluminate cement mortar lining. This lining protects the internal surface from corrosion, tuberculation and bacteriogenic acid attack when conveying aggressive fluids common in sewage and wastewater DATAS izes DN 100 - DN 750 Certification TYTONINTEGRAL pipes are certified to: - AS/NZS 2280 Ductile iron pipes and fittingsEnd Connections TYTON push-on rubber ring joint TYTON-LOK gaskets are also available for restrained joints up to DN 375 rated to PN 16 External Coating Zinalium ZnAl alloy 400g per m2 Red synthetic resin 100 mCEMENT MORTARDUCTILE IRONZINC-ALUMINIUM ALLOYPORE SEALER 100 mPORE SEALER 100 mZINC RICH PAINTZINALIUM ACTIVE CORROSION PROTECTION 5No sleeving required.

8 Sewage or aggressive waters with pH values of 4 to 12. TYTONINTEGRALFOR SEWER & WASTEWATERMANUFACTURED TO AS 2280 FOR THE AUSTRALIAN WATER INDUSTRY. DN 100 - DN 750 TYTONINTEGRAL combines the best features of TYTON proven Ductile Iron Pipeline Systems with materials that provide high resistance to chemical attack and is achieved by using calcium aluminate cement (CAC) in lieu of sulphate resisting (SR) cement in the barrel lining. CAC is an effective lining for aggressive fluids with extreme pH values and/or abrasive with Zinalium external protection, TYTONINTEGRAL Ductile Iron Pipes are a comprehensive and cost effective solution for wastewater delivers with: A lining suitable for the transport of sewage or aggressive waters with pH values of 4 to 12 Faster laying with no sleeving required, increased efficiency, and reduced cost means more savings Active corrosion protection with 400g per m2 ZnAl Alloy Zinalium gives a longer lasting Water commissioned the renewal of 242 metres of a two kilometre, DN 100 cast iron pipeline due to main breaks.

9 It was also a prudent time to take advantage of the opportunity to up-size the main to facilitate for further urban growth in the area. TYTONHYDROCLASS was selected due to a perceived risk of presence of hydrocarbons in the soil as there was previously a petrol station along the pipe alignment. A special order was placed with Saint Gobain PAM, the worlds leading manufacturer of DI pipe , for the first shipment of Zinalium coated pipe to Australia specifically for this project in the required time CONTRACTORC omdain Infrastructure, Bray CivilINTERVIEWPaul McCloskey Installation SupervisorSAVINGS COST OF SLEEVING- Installation time 10-15 minutes per pipe - 2 people to install sleeving- 1 person to drive load shift equipment- 1 x load shift equipment- Plus actual cost of sleeving- Approximately 7% cost saving overallCOMMENTSB rilliant Product, makes DI pipe installation much quicker and simpler.

10 Takes away the reliance on good sleeving installation for protection."Brilliant product, makes DI pipe installation much quicker & simpler"6 ZINALIUM ACTIVE CORROSION PROTECTIONINSTALLATION CASE STUDYTYTONHYDROCLASS JAMBEROODN 100, DN 150, DN 200 INSTALLED AT JAMBEROO JUNE 2016 ZINALIUM ACTIVE CORROSION PROTECTION 7 ACTIVE CORROSION PROTECTIONTYTON DUCTILE IRON PIPEVIADUX PTY LTD PO BOX 1025, PARRAMATTA, NEW SOUTH WALES 2124 AUSTRALIA / / PHONE 1300 VIADUX All Viadux trademarks and logos are owned by Viadux Pty Ltd. The words TYTON , TYTON-LOK and TYTON JOINT are United States pipe and Foundry Co. Inc. trademarks and are registered as such in the United States Patent Office and some 45 other countries.