Example: dental hygienist

USED WITH Part No. 3107206 - Bryant R.V

RECORD THIS UNIT INFORMATION FOR FUTURE. REFERENCE: Model Number_____. Serial Number _____. Date Purchased _____. 579 Series BRISK AIR. 590 Series QUICK COOL. 595 Series QUICK COOL. Roof Top Air Conditioner used with . part No. 3107206 . Air Distribution Box Kit USA. SERVICE OFFICE. The Dometic Corp. PRE-WIRED FOR OPTIONAL HEAT PACKAGE. 509 So. Poplar St. LaGrange, IN 46761. (219) 463-4858. CANADA. Dometic Dist. 637G. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7 . (519) 653-4390 CERTIFIED. LR 23565. For Service Center Assistance Call: 800-544-4881.

3 c. LOW COOL: Selected when room at desired comfort level and needs to be maintained. Normally this speed used for night time operation. NOTE: The blower runs continuously to circulate

Tags:

  With, Used, Part, Used with part no, 3107206

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of USED WITH Part No. 3107206 - Bryant R.V

1 RECORD THIS UNIT INFORMATION FOR FUTURE. REFERENCE: Model Number_____. Serial Number _____. Date Purchased _____. 579 Series BRISK AIR. 590 Series QUICK COOL. 595 Series QUICK COOL. Roof Top Air Conditioner used with . part No. 3107206 . Air Distribution Box Kit USA. SERVICE OFFICE. The Dometic Corp. PRE-WIRED FOR OPTIONAL HEAT PACKAGE. 509 So. Poplar St. LaGrange, IN 46761. (219) 463-4858. CANADA. Dometic Dist. 637G. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7 . (519) 653-4390 CERTIFIED. LR 23565. For Service Center Assistance Call: 800-544-4881.

2 Improper installation, ad- Une mauvaise installation, de justment, alteration, service mauvais r glages, modifications ou or maintenance can cause op rations d entretien peuvent injury or property damage. endommager les biens ou m me Refer to this manual. For blesser. Se reporter la notice. Pour assistance or additional obtenir de l aide ou des information consult a quali- reseignements compl mentaires, fied installer or service consulter un installateur qualifi ou agency. une agence de service apr s-vente. MODELS. INSTALLATION & OPERATING INSTRUCTIONS REVISION Form No.

3 3/98. (Replaces ). 1998 The Dometic Corporation LaGrange, IN 46761 1. 1. SPECIFICATIONS. 57912 57915 57915 57915 .421 .521 .621 MODEL NUMBER .621 .622 .426 .422 .526 .522 .626 .622 Nominal Capacity (BTU/HR) 7,100 11,000 13,500 13,500 13,500 15,000 15,000. Electrical Rating 115 VAC, 60 Hz., 1 PH. Compr. Rated Load Amps Fan Motor Rated Load Amps Compr. Locked Rotor Amps Fan Motor Locked Rotor Amps Heater Amps/Watts @ 120 VAC Amps; 1530 Watts; at 120 Volts AC. Refrigerant (R22) oz. Minimum Wire Size * 12 AWG Copper up to 24 ft. Circuit Protection 20 Amp Time Delay Fuse or HACR Circuit Breaker Installed Weight (Pounds) 75 93 100 95 95 110 111.

4 Minimum Generator 1 UNIT KW KW. Size ** 2 UNITS KW KW. * For lengths over 24 ft., consult the National Electrical Code. ** The Dometic Corp. gives general guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered. Also keep in mind generators lose power at high altitudes and from lack of maintenance. 2. PRECAUTIONS 3. OPERATING INSTRUCTIONS. A. CONTROLS: IMPROPER INSTALLATION MAY DAMAGE 1.

5 The Selector Switch has eight positions includ- EQUIPMENT, COULD ENDANGER LIFE, CAUSE ing "OFF". This controls fan speed, heating SERIOUS INJURY AND/OR PROPERTY DAM- mode, and cooling modes. 2. The Thermostat controls the temperature range AGE. from 65o F on the coldest side to 90oF on the A. Read installation and operating instructions carefully warmest side. In the cooling mode, the com- before attempting to start your air conditioner. pressor ON/OFF controlled by the thermostat B. The Dometic Corporation will not be liable for any setting.

6 Damages or injury incurred due to failure in following these instructions. B. COOLING OPERATION: C. Installation must comply with the National Electrical 1. Set the thermostat at the desired temperature Code and any State or Local Codes or regulations. level. D. DO NOT add any devices or accessories to this air 2. Select the fan speed that best satisfies your conditioner except those specifically authorized by needs: Dometic. a. HIGH COOL: Selected when maximum E. This equipment must be serviced by qualified person- cooling and dehumidification required.

7 Nel and some states require these people to be b. MED. COOL: Selected when normal or licensed. average cooling required. 2. c. LOW COOL: Selected when room at Air conditioners have a greater tendency to frost when desired comfort level and needs to be the outside temperature is relatively low. This may be maintained. Normally this speed used for prevented by adjusting the thermostat control knob to night time operation. a warmer setting (counter clockwise). Should frosting continue, operate on LOW, MED. or HIGH FAN. NOTE: The blower runs continuously to circulate setting until the cooling coil is free of frost.

8 Air and maintain an even temperature. The compres- sor will come on as cooling is required to maintain the 5. GENERAL INFORMATION. selected temperature level. The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and AFTER SHUTTING THE AIR CONDITIONER DOWN. improve the performance of the air conditioner. Dur- with EITHER SELECTOR SWITCH OR THERMO- ing extremely high outdoor temperatures, the heat STAT, WAIT AT LEAST TWO (2) MINUTES BE- gain of the vehicle may be reduced by: FORE RESTARTING.

9 THIS ALLOWS THE RE- a. Parking the RV in a shaded area FRIGERANT PRESSURE TO EQUALIZE AND COM- b. Using window shades (blinds and/or curtains). PRESSOR TO RESTART EASILY. c. Keeping windows and doors shut or minimizing usage C. FAN OPERATION: d. Avoiding the use of heat producing appliances This will circulate the air in your RV without cooling or heating. There are three positions: HIGH FAN, MED. Starting the air conditioner early in the morning and FAN or LOW FAN to select from, depending upon giving it a "head start" on the expected high outdoor personal choice.

10 Ambient will greatly improve its ability to maintain the desired indoor temperature. D. HEATING OPERATION: ( with Optional Heat Kit Installed). NOTE: This electric heater will not replace a fur- NOTE. nace for heating your RV in cold weather. The intent The manufacturer of this air conditioner will not be is to remove the chill on cool days or mornings. responsible for damage caused by condensed mois- 1. Turn the selector switch to "OPT. HEAT". ture on ceilings or other surfaces. Air contains mois- 2. The Heater will come on and begin heating.