Example: barber

User Manual - FAAC Gate Systems

user Manual :The 400 Operator ContentsImportant Safety Information2 The 400 Operator 3 Operator Label 3 General Characteristics 4 Manual Release Mechanism 5 Maintenance 5 The 400 Operator 5 The Gate System 5 Limited Warranty 6 FAAC International, Lexington AvenueCheyenne, WY ! To reduce the risk of injury or death1. READ AND FOLLOW ALL Never let children operate or play with gate controls. Keep the remote control away from Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING Use the emergency release only when the gateis not KEEPGATES PROPERLYMAINTAINED.

User Manual: The 400 Operator Contents Important Safety Information 2 The 400 Operator 3 Operator Label 3 General Characteristics 4 Manual Release Mechanism 5

Tags:

  Manual, User, User manual, Faca

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of User Manual - FAAC Gate Systems

1 user Manual :The 400 Operator ContentsImportant Safety Information2 The 400 Operator 3 Operator Label 3 General Characteristics 4 Manual Release Mechanism 5 Maintenance 5 The 400 Operator 5 The Gate System 5 Limited Warranty 6 FAAC International, Lexington AvenueCheyenne, WY ! To reduce the risk of injury or death1. READ AND FOLLOW ALL Never let children operate or play with gate controls. Keep the remote control away from Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING Use the emergency release only when the gateis not KEEPGATES PROPERLYMAINTAINED.

2 Read the owner's Manual . Have a qualified service person make repairs to gate The entrance is for vehicles must use separate SAVE THESE Only qualified personnel should install this equipment. Failure to meet this requirement could cause severe injury and/or death, for which the manufacturer cannot be held The installer must provide a main power switch that meets all applicable safety Clearly indicate on the gate with a minimum of 2 warning signs (visible from either side of the gate) that indicate the following: .The gate is automatic and could move at any time, posing a serious risk of entrapment.

3 Children should not be allowed to operate the gate or play in the gate gate should be operated only when it is visible to the operator and the when the area is free of people and Devices such as reversing edges and photocells must be installed to provide better protection for personal property and Use this equipment only in the capacity for which it was designed. Any use other than that stated should be considered improper and therefore When using any electrical equipment, observe some fundamental rules: Do not touch the equipment with damp or humid hands or not operate the equipment with bare not allow small children or incapable persons to use the If a gate system component malfunctions, turn off the main power before making any attempt to have it Do not attempt to impede the movement of the gate.

4 You may injure yourself as a This equipment may reach high temperatures during operation; therefore, do not touch the external housing of the Learn to use the Manual release mechanism according to the procedures found in this Before carrying out any cleaning or maintenance operations, turn off the main To guarantee the efficiency of this equipment, the manufacturer recommends that qualified personnel periodically check and maintain the Safety InformationThe owner and/or operator of this system must read and understand this Manual and the safety instructions supplied with other components of the gate information should be retained by the owner and/or operator of the 400 Operator400 Model ParameterStandardHigh SpeedSlow SpeedLongModelCBC2 CBCR2 SBS1 CBC2 CBA3 CBAR3 CBAC4 CBAC4 CBACR4SB1 Duty typeApartment, subdivision, industrial, and commercial applicationsDuty cycle100% Duty CycleMaximum leaf length5.

5 Ft (m)18 ( )12 ( )20 (6)18 ( )Maximum leaf weight, lb (kg)1300 (600)900 (400)2000 (900)1300 (600)Maximum leaf swing, deg115125 Thrust and traction, lb (kg)0-1760 (0-800)90 deg opening time, temperature range, -33 to 165deg F (deg C)(-36 to 75)Thermal cut out, deg F (deg C)212 (100)Hydraulic lockingOpened and/or closedNoneOpened and/or closedOperator dimensions, 40 x 3 5/16 x 3 5/16 47 1/2 x 3 5/16 x 3 5/16 l x w x h, in. (cm) (102 x x )(121 x 3 x )Operator weight, lb (kg)19 ( )Power voltage required, VAC7115 VAC 10%, 60 Hz, or 230 VAC +6 or -10%, 60 HzType of oilLubrication Engineers - MONOLEC 6105 Oil quantity, qt (l)2 1/3 ( )2 7/8 ( )1 The operator requires external Locks in the extended position.

6 The hydraulic lock is a service device, not a security Locks in the retracted position. The hydraulic lock is a service device, not a security Locks in both the extended and retracted positions. The hydraulic lock is a service device, not a security External locks are recommended if the gate leaves are 12 ft ( m) or The time may vary 10%.7 Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.Technical DataOperator LabelThe labels on your 400 operator list the following information:.Model :Removing or defacing (ie. painting over) the labels will void the ULlabels must be visible for inspection4 The 400 OperatorGeneral CharacteristicsThe FAAC 400 Operator is an automatic gate operator for a swinging gate leaf.

7 It can accommodate a gate leaf of up to 2000 lb (900 kg) and up to 20 ft (6 m) in length. The self-contained 400 Operator is an electro-hydraulic unit consisting of an electric motor, a pump, a valve assembly, and a hydraulic cylinder, all housed in an anodized aluminum oil 400 Operator can be used to swing the gate leaf inwardor outward. Most versions provide hydraulic locking in atleast one position, either opened or closed, depending on how it was hydraulic lock is a service device rather than a securitydevice. Additional, external locks are recommended under the following conditions.

8 You are installing the Model 400 length of the gate leaf is 12 ft or installation requires tight site is subject to site is subject to strong or very gusty are installing a solid face gate. For its protection, the single-phase, bidirectional motor shuts off automatically if its operating temperature reaches212 deg F (100 deg C). Also for the protection and properoperation of the 400 Operator, each gate leaf on which it isinstalled must have a fixed positive stop in both the openedand closed 400 Operator includes a key-operated Manual Releasemechanism. It is a device that disengages (or engages) thehydraulic system of the 400 the hydraulicsystem is disengaged, you can open and close the gate leaf by hand.

9 Such Manual operation of the gate is necessary during power failures. (See page 5 for more details.)Reversing devices (such as inductive loops and photocells)should be installed to provide more complete protection for people and electronic control panel is a microprocessor-based controller that accepts a wide range of product accessories and reversing devices, thus allowing for flexible gate system :The 450 provides inputs for opening reversing devices and closing reversing devices. FAAC strongly recommends the use of reversing devices, such as photocells or other non-contact devices include photocells, inductive loops, and so forth.

10 All of the reversing devices should have contacts of the normally closed ( ) type. Where you connect adevice depends on whether you want the device to operateduring opening or during closing. Note: Areversing device is required for a recognized : Failure of an opening reversing device causes a gate to lock in the closed position and requires the use of the Manual Release following logics are available on the 450 MPS:.A(automatic): The gate opens on command and automatically closes after a pause phase. Asecond command on opening is ignored; a second command during the pause phase causes the gate to close immediately; a second command during closing reopens the (security): The security mode is like Alogic except that a second command during opening immediately closes the (semi-automatic): This mode requires a command to open and a command to close.


Related search queries