User Manual Single Phase Energy Meter - INOGATE

User Manual Single Phase Energy MeterHXE12-KP Hexing Electrical Co., Ltd. [ ] Meter User Manual -HXE12-KP 2 / 30 Introduction Range of validity The present user Manual applies to the Meter specified on the title page. Purpose The user Manual contains all the information required for application of the meters for the intended purpose. This includes: z Provision of knowledge concerning characteristics, construction and function of the Meter z Information about possible dangers, their consequences and measures to prevent any danger z Details concerning the performance of all work throughout the service life of the Meter Target group The contents of this user Manual are intended for technically qualified personnel of Energy supply companies responsible for the Meter planning, installation, operation and maintenance of the Meter .

Meter User Manual-HXE12-KP 2 / 30 Introduction Range of validity The present user manual applies to the meter specified on the title page.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of User Manual Single Phase Energy Meter - INOGATE

1 User Manual Single Phase Energy MeterHXE12-KP Hexing Electrical Co., Ltd. [ ] Meter User Manual -HXE12-KP 2 / 30 Introduction Range of validity The present user Manual applies to the Meter specified on the title page. Purpose The user Manual contains all the information required for application of the meters for the intended purpose. This includes: z Provision of knowledge concerning characteristics, construction and function of the Meter z Information about possible dangers, their consequences and measures to prevent any danger z Details concerning the performance of all work throughout the service life of the Meter Target group The contents of this user Manual are intended for technically qualified personnel of Energy supply companies responsible for the Meter planning, installation, operation and maintenance of the Meter .

2 Hexing Electrical reserves the right of final interpretation Meter User Manual -HXE12-KP 3 / 30 TABLE OF CONTENTS INTRODUCTION .. 2 1. OVERVIEW .. 5 FRONT VIEW .. 5 HIGHLIGHTS .. 5 PRINCIPLE OF OPERATION .. 6 BASIC PARAMETERS .. 6 STANDARDS .. 7 2. MAIN FUNCTIONS .. 8 MEASUREMENT .. 8 Energy .. 8 Instantaneous Values .. 8 Billing Data .. 9 LCD DISPLAY .. 9 Physical Characteristics .. 9 LCD Full Screen Display .. 10 LCD Display Items .. 10 LCD Display Modes .. 10 Status Indicator .. 11 COMMUNICATION INTERFACES .. 11 Optical Communication .. 12 PLCC ommunication .. 12 GPRS Communication(optional with PLC) .. 12 KEYPAD .. 13 STS .. 13 Recharge .. 13 Management TOKEN .. 14 Modify Security Key .. 15 Te s t TO K E N .. 15 SHORT CUT KEYS .. 17 LOW CREDIT ALARM .. 18 EMERGENCY CREDIT .. 18 FRIENDLY MODE .. 20 SMS RECHARGE.

3 20 Input TOKEN number .. 20 Input Shortcut Key .. 20 SMS Alarm .. 21 Mobile Phone Number Binding .. 21 LOAD CONTROL .. 21 EVENT RECORDS .. 21 Event Type 1 .. 21 Event Type 2 .. 22 Event Type 3 .. 22 Meter User Manual -HXE12-KP 4 / 30 Event Type 4 .. 22 Event Type 5 .. 22 Event Type 6 .. 22 LOAD PROFILE .. 22 DAYLIGHT SAVING TIME .. 23 CONTACTOR .. 23 Physical Characteristics .. 23 Control Logic .. 23 Reason of Operation .. 23 RTC .. 24 BATTERY .. 24 3. DIMENSIONS AND INSTALLATION .. 24 DIMENSIONS .. 24 Outline Drawing .. 25 Terminal Block Drawing .. 26 CONNECTION DIAGRAM .. 27 INSTALLATION REQUIREMENTS .. 27 4. STORAGE AND TRANSPORTATION .. 27 ANNEX A .. 28 MMeter User M 1. OvervHXE12-KPIts main funcontrol, Front Highli Pr Baan D Cl H Re Bu Pl So Ri SuManual-HXEview P Single phanctions inclypad input aView ights repayment mased on STnd the only LMS/COSE losed type duman machecharge infouilt-in contaluggable PLome basic qich event reupport logoE12-KP ase two wirelude energyand inquiry,mode solvesS (StandardinternationaEMCommudesign avoidhine interfacformation is actor, and vLC/GPRS mqueries and ecords.)

4 Ff of Meter , 5 / 3e prepaid ky measureme, anti-tampes the probled Transfer Sal specificatunication prods external ce availabletransferredvaried contromodule suppeasy operatand the cre0 keypad meteent, data diering, etc. em of difficuSpecificatiotion on prepotocol, whicattack throue: keypad inpd in the formol methods ports remotetion can be dedit in meterer is designesplay, commult collectioon), which ipaid systemch ensures gugh open input and LCm of TOKENare supporte communicdone via ker can be retued for the pmunication,on of electris an open sm. good interopnterface. D display. N. ted. cation. eypad. urned to cuspurpose of p prepaymencity fee. secure transperability. stomer. prepaymentnt, contactofer standardt. r d Meter User Manual -HXE12-KP 6 / 30 Principle of Operation HXE12-KP comprises of following components: Energy measuring unit: voltage sampling, current sampling, measuring integrated circuit; Data processing unit: MCU, memory; Power supply unit: AC power supply, battery; Input/output unit: LCD display, PLC/GPRS communication, optical port, keypad; Load control unit: contactor.

5 Basic Parameters Parameter Characteristics Reference voltage 220 VAC Working voltage 70 Un 120 Un Meter User Manual -HXE12-KP 7 / 30 Frequency (50 5)Hz Current 5(60)A Accuracy Cl for kWh Starting current 4 Ib impulse constant Active: 1600 imp/kWh Working temperature Normal working temperature: -25 C +60 C Extreme working temperature: -40 C +70 C Relative humidity 95% Power consumption in voltage circuit , 10VA Power consumption in current circuit 1VA Degrees of protection IP54 Fast transient burst 4kV Electrostatic discharges Contact discharge8kV, air discharge 15kV Insulation 1 minute under 4kV, 50Hz Impulse voltage 8 kV Standards Standards Descriptions IEC62052-11 Electricity metering equipment ( ) General requirements, tests and test conditions Part 11: Metering equipment IEC62053-21 Electricity metering equipment ( ) - Particular requirements - Part 21: Static meters for active Energy (classes 1 and 2) IEC62053-31 Electricity Metering Equipment ( ) - Particular Requirements - Part 31: Pulse Output Devices for Electromechanical and Electronic Meters (Two Wires Only) IEC62055-41 Electricity metering - Payment systems - Part 41.

6 Standard transfer Meter User Manual -HXE12-KP 8 / 30 specification (STS) - Application layer protocol for one-way token carrier systems IEC62055-51 Electricity metering - Payment systems - Part 51: Standard transfer specification (STS) - Physical layer protocol for one-way numeric and magnetic card token carriers IEC62056-61 Electricity metering - Data exchange for Meter reading, tariff and load control - Part 61: Object identification system (OBIS) IEC62056-62 Electricity metering - Data exchange for Meter reading, tariff and load control - Part 62:Interface classes IEC62056-46 Electricity metering - Data exchange for Meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol IEC62056-53 Electricity metering - Data exchange for Meter reading, tariff and load control - Part 53: COSEM application layer IEC62056-47 Electricity metering Data exchange for Meter reading, tariff and load control Part 47:COSEM transport layer for IP networks 2.

7 Main Functions Measurement Energy z The Meter measures both forward and reverse active Energy in the range of ~ z Measurement mode: Forward= forward + reverse Reverse= reverse Instantaneous Values z Active power z Voltage z Current z Power factor z Frequency Meter User Manual -HXE12-KP 9 / 30 Billing Data z Monthly frozen Energy : last 12 months data of monthly frozen occurrence time, total active Energy ,total reverse active Energy . z Daily frozen Energy : last 62 days data of daily frozen occurrence time, total active Energy , total reverse active Energy . z Monthly frozen credit: last 12 months data of monthly frozen occurrence time, remaining credit. z Daily frozen credit: last 62 days data of daily frozen occurrence time, remaining credit. Monthly frozen time is configurable in the format of XX(day):XX(hour) from 1st to 28th of every month.

8 The default setting is 1st day 00 hour. Daily frozen time is configurable in the format of XX(hour):XX(minute). The default setting is 00:00. LCD Display Physical Characteristics z Visual size of LCD: *21mm; z Size of digit: * ; z z Working temperature of LCD: -30 C 80 C; z High-contrast; z Wide viewing angle; z Anti-ultraviolet. Meter User Manual -HXE12-KP 10 / 30 LCD Full Screen Display LCD Display Items Display item Description Data display area OBIS code display area Unit display area Communication Reverse indication Low battery Contactor connected Contactor disconnected Recharge successful Recharge failed GPRS signal S1~S8 Event status indicator LCD Display Modes There are five types of LCD display modes: automatic scrolling display, push button display, keypad display, power off display, and Meter abnormal display.

9 Z Automatic scrolling display Meter display mode is default as automatic scrolling display when power on. After Meter operates for a certain period, which is automatic scrolling display interval default as 3s, Meter User Manual -HXE12-KP 11 / 30 LCD display will switch automatically to next page in sequential order circularly. Maximum 32 display pages can be configured, for details please refer to Annex A. z Push button display Once press the button in the front, automatic scrolling display/power off display will switch to push button display. LCD display switches to next page in sequential order circularly at each button-push. When there is no button-push within 30s, push button display will switch back to automatic scrolling display/power off display. Maximum 32 display pages can be configured, for details please refer to Annex A.

10 Z Keypad display When press the numbers in the keypad, the Meter will enter keypad display mode and display relevant numbers in LCD. If there is no keypad operation after 20s, the Meter goes back to automatic scrolling display mode(when there is power in the grid) or power-off display mode(when there is no power in the grid). When pressing effective shortcut key or TOKEN and press ENTER key, the Meter will display relevant indicating message. After 10s it will go back to automatic scrolling display mode(when there is power in the grid) or power-off display mode(when there is no power in the grid). z Power off display Meter only displays credit of Meter during power off. z Meter abnormal display Once fault or damage of Meter memory is detected, automatic scrolling display will stop and LCD will be fixed to display abnormal code Error . Status Indicator z When Meter cover is open, S2 indicates; z When terminal cover is open, S3 indicates; z When Meter is overloaded, S4 indicates; z When Meter cover open and terminal cover detection function is disabled, S5 indicates; Communication Interfaces Meter has one optical communication port, and one PLC/GPRS communication port(only one communication module between PLC and GPRS can be chosen for one Meter ).