USG DUROCK BRAND GLASS-MAT TILE BACKERBOARD
Property Unit of Measure Test Method 5/8 in. (15.9 mm) USG Durock™ Brand Glass-Mat Tile Backerboard (UL Type SGX) 1/2 in. (12.7 mm) USG Durock™ Brand Glass-Mat Tile Backerboard Weight psf ASTM C473 2.5 1.7 Flexural strength lbf ASTM C473 >177 (perpendicular) >100 (parallel) >100 (perpendicular) >80 (parallel) Nail pull lb (0.25 in. head ...
Tags:
Methods, Glass, Measure, Ielts, Brand, Backerboard, Brand glass mat tile backerboard
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
USG DUROCK BRAND CEMENT BOARD SYSTEMS
www.usg.comSTANDARDS USG Durock® cement board exceeds ANSI standards for cementitious backer units (CBU). See ANSI A118.9 for test See ANSI A118.9 for test methods and specifications for CBU and ANSI A108.11 for interior installation of CBU.
USG Fire-Resistant Assemblies Catalog (English) - …
www.usg.com4 USG Fire-Resistant Assemblies Fire Protection USG is the undisputed leader among building material manufacturers in providing products and systems designed to keep people safe from fire.
USG Area Separation Wall Systems Brochure …
www.usg.comArea separation walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants in adjacent dwellings.
System, Area, Safety, Walls, Brochure, Separation, Usg area separation wall systems brochure
Fire-Resistant Assemblies Brochure (English) - SA100
www.usg.comUser’s Guide Use this brochure to determine fire ratings for CGC products and systems. This brochure provides: — Comprehensive information about fire-rated assemblies
Fire, English, Brochure, Resistant, Assemblies, Fire resistant assemblies brochure, Sa100
Technical Document Seismic Technical Guide - USG
www.usg.com4 Hanger Wire Attachment Application Anchorage The International Building Code (IBC), through references to ASCE/SEI 7 Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI), defines
American, Guide, Design, Seismic, Document, Engineer, Technical, Society, Case, Minimum, Load, Civil, American society of civil engineers, Technical document seismic technical guide, Sei 7 minimum design loads
Technical Document Seismic Technical Guide - USG
www.usg.comTechnical Seismic Technical Guide Document Light Duty Suspension Systems ASTM C6351 addresses the load carrying capability of main tees, categorizing them as Light, Intermediate or Heavy Duty.
CGC SHAFT WALL SYSTEMS - USG
www.usg.comC-H studs in a progressive manner, with gypsum panels, gypsum fiber panels or cement board applied to the face. All details, specifications and data contained in this literature are intended as a …
Manual Técnico USG Tablaroca® (Español)
www.usg.comUSG Manual Técnico USG TABLAROCA® USG SHEETROCK® Manejo, almacenaje, especificación, instalación y recomendaciones generales.
0 ICC-ES Evaluation Report ESR-1222 - USG
www.usg.comThe USG suspended ceiling framing systems described in this report are suspended, exposed framing, concealed ceiling assemblies used in fire-rated and non -resistance -
Technical Document Seismic Technical Guide - USG
www.usg.comTechnical Seismic Technical Guide Document Compression Posts USG Donn® Brand Compression Post providesidrig support for a ceiling suspension system in seismic applications. Telescoping compression posts attach to the main tees at each splayed wire location, preventing upward
Guide, Seismic, Document, Technical, Technical document seismic technical guide
Related documents
A Method to Measure Humidity Based on Dry-Bulb and Wet ...
maxwellsci.comRes. J. App. Sci. Eng. Technol., 6(16): 2984-2987, 2013 2986 Calculate difference of dry-bulb and wet-bulb temperatures Find the upper and lower limits of the
Based, Methods, Measure, Humidity, Method to measure humidity based on dry
DETERMINATION OF MOISTURE CONTENT
www.ico.orgThese devices measure the relative humidity in the air space between beans. ... This principle is based on variations of apparent density of coffee throughout ... for dry cherries and dry parchment though there is no ISO method to determine moisture content of these …
BLOOD PRESSURE UNIT USER’S MANUAL
www.medline.comstress, exercise, physiologic condition, measurement site, body position, temperature, humidity, altitude, and many other factors. Remember that blood pressure can also vary throughout the day. It is important to take measurements at the same time each day, and under the same conditions.
LEAK TESTING METHODOLOGIES - Vacuum Engineering …
vac-eng.comLeak Testing Methodologies Tel.: (UK): +44 (0)161 866 88 60 - (US): +1 734 4874566 info@vac-eng.com www.vac-eng.com BUBBLE TEST This method consists of pressurising the component (usually with dry air or nitrogen),
ATTENTION! READ BEFORE INSTALLING!
pdf.lowes.com• Dry • Structurally sound • Clean: Thoroughly swept and free of all debris • Level: Flat to 3/16” per 10-foot radius Wood subfloors must be dry and well secured. Nail or screw every 6” along joists to avoid squeaking. If not level, sand down high spots and fill low spots with a Portland Based leveling patch.
Physical Access Control - HHS.gov
www.hhs.govGas, CO2, foam, dry powders: Class C: Electrical. Gas, CO2, dry powders: Class D: Combustible Metals. Dry powders: Water can cause extensive damage to equipment, infrastructure, and computers. − Mold and mildew can also be a factor when unwanted water is introduced into an environment. − Organizations should be able to detect leaks and ...