Example: tourism industry

VENT-FREE GAS WALL HEATER OWNER’S OPERATION AND ...

VENT-FREE GAS WALL. HEATER . owner 'S OPERATION AND. installation MANUAL. BLUE FLAME MODELS. BF30T-BB. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable va- pors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions . If you cannot reach your gas supplier, call the fire department.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali-fied installer, service agency or the gas supplier. WARNING: This appliance is equipped for natural and propane ...

Tags:

  Installation, Owner, Instructions, Natural, Propane

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of VENT-FREE GAS WALL HEATER OWNER’S OPERATION AND ...

1 VENT-FREE GAS WALL. HEATER . owner 'S OPERATION AND. installation MANUAL. BLUE FLAME MODELS. BF30T-BB. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable va- pors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions . If you cannot reach your gas supplier, call the fire department.

2 installation and service must be performed by a quali- fied installer, service agency or the gas supplier. WARNING: This appliance is equipped for natural and propane gas. Field conversion is not permitted other than between natural or propane gases. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST, Monday through Friday TABLE OF CONTENTS. 3 18. Qualified Installing 4 Electrical 20. 5 Electrical 20. Product 5 Inspecting 21. Local 5 Care And 22. Preparing For 6 23. 6 Technical 26. Water Vapor: A By-Product Of Replacement 27. Unvented Room 6 27.

3 Air For Combustion and 7 Service 27. 9 30. SAVE THIS BOOK. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This is an unvented gas-fired HEATER . It uses air (oxygen). from the room in which it is installed. Provisions for ad- equate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 7 of this manual. WARNING: Improper installation , adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

4 This appliance may be installed in an aftermarket,* per- manently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with propane or natural gas. Field conversion by any other means including the use of a kit is not permitted. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. PATENT INFORMATION. This product may be covered by one or more of the following United States patents: 9,829,195 9,423,123 9,441,833 9,518,732 9,752,779 9,416,977 8,764,436. 8,568,136 8,516,878 8,297,968 8,281,781 8,235,708 7,967,006. 7,967,007 7,730,765 7,677,236 7,607,426 7,434,447.

5 2 HearthSense 200549-05A. SAFETY. IMPORTANT: Read this owner 's agent is added to the gas. The odor helps you manual carefully and completely detect a gas leak. However, the odor added to before trying to assemble, op- the gas can fade. Gas may be present even though no odor exists. erate, or service this HEATER . Improper use of this HEATER can WARNING: FIRE, EXPLOSION. cause serious injury or death AND ASPHYXIATION HAZARD. from burns, fire, explosion, electrical shock and carbon Improper adjustment, altera- monoxide poisoning. tion, service, maintenance, or installation of this HEATER or its Only a qualified installer, service controls can cause death or agent, or local gas supplier may serious injury.

6 Install and service this product. Read and follow instructions and precautions in User's Informa- WARNING: Keep the appli- tion Manual provided with this ance area clear and free from HEATER . combustible materials, gasoline, and other flammable vapors and WARNING: Do not use any liquids. accessories not approved for use with this HEATER . WARNING: This appliance can be used with propane or WARNING: Carefully super- natural gas. It is shipped from vise young children when they the factory adjusted for use with are in the room with the HEATER . propane . WARNING: The fire screen or This appliance is only for use guard designed for this unvent- with the type of gas indicated on ed appliance must be installed the rating plate.

7 This appliance prior to OPERATION . is not convertible for use with other gases. WARNING: Due to high tem- peratures, the appliance should DANGER: Carbon monoxide be located out of traffic and away poisoning may lead to death! from furniture and draperies. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble WARNING: HEATER becomes the flu, with headaches, dizziness or nausea. very hot when running. Children If you have these signs, the HEATER may not be and adults should be alerted working properly. Get fresh air at once! Have to the hazards of high surface HEATER serviced. Some people are more af- temperatures and should stay fected by carbon monoxide than others.

8 These include pregnant women, people with heart or away to avoid burns and cloth- lung disease or anemia, those under the influ- ing ignition. HEATER will remain ence of alcohol and those at high altitudes. hot for a time after shutoff. Allow natural AND propane GAS: natural and surfaces to cool before touching. propane gas are odorless. An odor-making 200549-05A HearthSense 3. SAFETY. may create a white powder residue within WARNING: Do not place burner box or on adjacent walls or furniture. clothing or other flammable 8. Do not use HEATER if any part has been material on or near the appli- under water. Immediately call a qualified ance.

9 Never place any objects service technician to inspect the room HEATER and to replace any part of the in the HEATER . control system and any gas control which 1. Do not place propane supply tank(s) inside has been under water. any structure. propane supply tank(s) 9. Turn off and unplug HEATER and let cool must be placed outdoors. before servicing. Only a qualified service 2. Heaters with a maximum input over person should service and repair HEATER . 6,000 Btu/Hr shall not be installed in a 10. Operating HEATER above elevations of bathroom. Heaters with a maximum input 4,500 feet could cause pilot outage. over 10,000 Btu/Hr shall not be installed 11.

10 To prevent performance problems, do not in a bedroom. use propane fuel tank of less than 100 lbs. 3. This HEATER needs fresh air ventilation to capacity. run properly. This HEATER has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the HEATER if not enough fresh air is available. See Air for Combustion and Ventilation, pages 7. through 9. If HEATER keeps shutting off, see Troubleshooting, page 23. 4. Keep all air openings in front and bottom of HEATER clear and free of debris. This will ensure enough air for proper combustion. 5. If HEATER shuts off, do not relight until you have provided fresh, outside air.


Related search queries