FantechVentilation SolutionsKitchensfantech2 | KitchensfantechToday s Kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the entire family as well as the ideal place to congregate for informal entertaining. Let Fantech show you how to keep the kitchen clear of smoke, grease, steam and odors with a Ventilation system that works quietly and | KitchensfantechKitchens | 3 Kitchens | 3fantech4 | Kitchens3261547 How do I size my kitchen Ventilation system?Wall Mount Installations: 100 CFM per foot of hood widthBefore choosing your kitchen Ventilation fan, check with your local residential codes and the range manufacturer s recommendations. If the range manufacturer s recommendations are not available, use the information below to calculate the fan size.

fantech 6 | Kitchens Inline duct fans designed with airtight galvanized steel housings. Ideal for use with smaller, standard size ranges. Available in sizes from 303 CFM to 940 CFM.

Tags:

  Solutions, Ventilation, Fans, Kitchen, Inline, Ventilation solutions kitchens

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Ventilation Solutions Kitchens - Fantech

1 FantechVentilation SolutionsKitchensfantech2 | KitchensfantechToday s Kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the entire family as well as the ideal place to congregate for informal entertaining. Let Fantech show you how to keep the kitchen clear of smoke, grease, steam and odors with a Ventilation system that works quietly and | KitchensfantechKitchens | 3 Kitchens | 3fantech4 | Kitchens3261547 How do I size my kitchen Ventilation system?Wall Mount Installations: 100 CFM per foot of hood widthBefore choosing your kitchen Ventilation fan, check with your local residential codes and the range manufacturer s recommendations. If the range manufacturer s recommendations are not available, use the information below to calculate the fan size.

2 These recommendations follow the guidelines of the Home Ventilating Institute (HVI).Example: 36 (3 ft.) wide hood will require 300 Width 3 CFM per Foot x 100 Air flow [CFM] 300 Island Mount Installations: 150 CFM per foot of hood widthExample: 36 (3 ft.) wide hood will require 450 Width 3 CFM per Foot x 150 Air flow [CFM] 450 When using a gas cooktop or range, it is recommended that the hood liner be 6 wider than the | KitchensfantechKitchens | 59618fantechMakeup Air Solution1. inline supply fan2. Filter cassette3. Shut-off damper 4. Intake wall hood5. inline duct heater 16. Silencer7. Fast clamps kitchen Exhaust Solution1. inline exhaust fan6. Silencer8. Roof cap 29. kitchen hood 31 optional for cold climates2 supplied by others3 kitchen hood liners can support fans with total max amperage of 6 AmpsYour makeup air solution should be simple, yet effective.

3 Your Fantech makeup air system, along with your Fantech inline kitchen exhaust solution, will be quiet, comfortable and reliable. Under ideal conditions, even while preparing the largest and most demanding meals, your kitchen remains ventilated without pulling in air from every cracked window or crevice in your home. Every time an exhaust fan removes air fromyour home an equal volume of air must enter,this is called makeup air. Homes today arebuilt to tighter standards resisting infiltrationfrom outside air. With little to no leakage inthe building envelope, where does a powerfulrange hood get its makeup air? If the homedoes not have enough random air leaksaround the windows and doors, the makeupair is often pulled backwards from thechimney or water heater flue, this is calledbackdrafting. Since flue gasses from somecombustion appliance can include carbonmonoxide, backdrafting is dangerous and insome cases can be life Ventilation makes your kitchen a dreamKitchens | 5fantech6 | KitchensInline duct fans designed with airtight galvanized steel housings.

4 Ideal for use with smaller, standard size ranges. Available in sizes from 303 CFM to 940 CFM. Duct sizes from 6 to 12 . Speed-controllable Built-in thermal overload protection with automatic reset Can be installed in any position and outdoors Mounting bracket and hardware includedSpecification dataRC Roof Capspage 11FG Series inline Centrifugal FansModel*Rated powerVoltage / PsMax PsShippingweightUPC #WV / ~ FG 672120 / 8FG 6XL153120 / 3FG 8 119120 / 6FG 8XL142120 / 1FG 10138120 / 1FG 10XL196120 / 6FG 12181120 / 9FG 12XL301120 / 4 Performance shown is for installation type D - Ducted intlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the (accessories).* This product earned the ENERGY STAR by meeting strict efficiency guidelines.

5 All models meets ENERGY STAR , Inc. certifies that the models shown herein are licensed to bear the AMCA Seal. The ratings are based on the tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).Air flowFADEC3 3/4"2"Dimensions Duct connections are 1/8 smaller than duct size. Dimensional information is in inches. ModelA CDEFFG 6 611 3/86 1/417/8FG 6XL613 1/8711FG 8813 1/4611FG 8XL613 1/461 1/81FG 101013 1/44 3/41 1/81FG 10XL1013 1/44 13/161 1/41FG 1212166 11/161 1/41FG 12XL12166 11/161 1/21 AccessoriesRSK Backdraft Damperpage 11FC Mounting Clampspage 11 LDSilencerpage 11 SHL/SGHL Hood Linerspage 10fantechKitchens | 7 ACBDFGHEP owerful, smooth running mixed flow centrifugal fans designed for kitchen Ventilation systems.

6 Galvanized steel housings. The perfect size for use with commercial style ranges. Models from 836 CFM to 2016 CFM. Duct sizes from 8 to 12 . High efficiency impeller generates low noise 100% speed-controllable Integral thermal contacts Can be installed in any position Airstream temperatures up to 140 FDimensionsDimensional information is in 8XL81412 1/215 1/23/42 3/86 1/83/8 FKD 10101412 1/215 1/23/42 3/853/8 FKD 10XL1015 5/814153/42 3/86 3/83/8 FKD 121215 5/81412 1/23/42 3/85 1/83/8 FKD SeriesInline Centrifugal FansFantech, Inc. certifies that the FKD Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings powerVoltage / PsMax PsSones ShippingweightUPC #WV / ~ 8XL327120 / 2 FKD 10329120 / 2 FKD 10XL529120 / 7 FKD 12531120 / 0 Performance certified is for installation type D - Ducted inlet, Ducted outlet.

7 Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5ft. ( ) in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type D: ducted inlet hemisphericalfan sone levels. Ratings do not include the effect of duct end correction. All sone values shown are calculated at (static pressure in inches )1 Recommended speed control rating 5A 2 Recommended speed control rating 10 ASpecification dataAccessoriesRSK Backdraft Damperpage 11FC Mounting Clampspage 11 LDSilencerpage 11 SHL/SGHL Hood Linerspage 10RC Roof Capspage 11fantech8 | KitchensExterior mounted exhaust fans can provide the perfect solution when space is at a minimum. Ideal for homes, condominiums and apartment complexes. fans mount on an exterior wall.

8 Models are available from 242 CFM to 435 CFM. Duct sizes - from 4 to 8 . Wall mounted fan For high moisture, lint and dust laden air Excellent motor heat dissipation Permanently lubricated sealed ball bearings Ambient noise is kept outsideDimensionsDimensional information is in inches. Duct connections are 1/8 smaller than duct Hood Linerspage 10 RVF 4XL Exterior-Mount FanFC Mounting Clampspage 11 Specification dataModelDuct sizeRated powerVoltage / phaseMax. PsShippingweightUPC #inchWV / ~AcfmlbsRVF 6692120 / 9 RVF 6XL6149120 / 23065 4 RVF 8XL8151120 / 2 Performance shown is for installation type with duct inlet Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at inches WG. RVF Series performance is shown with ducted inlet.

9 This product is not UL listed for dryer exhaust.* Energy Star quilifiedModelA BCDERVF 65 7/810 1/41362 3/4 RVF 6XL5 7/810 1/41762 3/4 RVF 8XL 7 7/814 1/41762 3/4 Air flowACDBE fantechKitchens | 9 Direct drive centrifugal fans provide an excellent solution for residential or commercial Ventilation applications where the fan must be mounted on the exterior of the building. RE/REC models mount on a curb. Models are available from 227 CFM to 1008 CFM. Duct sizes - from 5 to 10 . Airflows up to 1008 cfm 100% speed-controlable Suitable for airstream temperatures of up to 140 F Excellent heat dissipation for long motor life Built-in thermal overload protection with automatic resetDimensionsAccessoriesRSK Backdraft Damperpage 11 SHL/SGHL Hood Linerspage 10 AABDCDCEBM odelABCDE 2RE 54 / REC 54 110 15/166515 1/21 1/2RE 6 / REC 613 15/166 1/4615 1/21 1/2RE 8XL / REC 8XL16 9/165 15/168201 1/2RE 10XL / REC 10XL20 13/1611 1/210201 1/2RE 10 XLT / REC 10 XLT20 13/1612 11/1610201 1/2 All dimensions in inches.

10 Male duct connector is 1/8 smaller than duct Supplied with 5 to 4 reducer2 For REC models onlyRE(C) Series Exterior Roof/Wall Centrifugal FansSpecification dataPerformance certified is for installation type A - Free inlet, Free outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5ft. ( ) in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical fan sone levels.* Sone value shown was calculated at (static pressure in inches ). Sone value shown was calculated at (static pressure in inches ).ModelRated powerVoltage /phaseMax. amps* PsMax PsSones ShippingweightUPC #WV / ~ 54 / REC 5419120 / *1142040 6 / 42045 1RE 6 / REC 687120 / *1442060 4 / 42065 9RE 8XL / REC 8XL153120 / *1942080 2 / 42085 7RE 10XL / REC 10XL394120 / 3142100 7 / 42105 2RE 10 XLT / REC 10 XLT531120 / 3342140 3 / 42145 8 Fantech , Inc.