Transcription of VII. Structural Design - Aercon AAC
1 VII. Structural DesignA. GeneralPage VII-2B. Floor PanelsPage VII-3C. Roof PanelsPage VII-6D. Diaphragm AnalysisPage VII-10E. Non-Load Bearing Wall PanelsPage Bearing Vertical Wall PanelsPage VII-21G. Blocks and LintelsPageVII-24H. VII-42b2b b< The following topics in thissection show the method for thestructural Design of Aercon panel and block are: Span graphs and diaphragmanalysis for floor panels androof panels Span graph and connections fornon-load bearing wall panels Load bearing and shear wallanalysis for load bearing verti-cal wall panels and blocksFor additional applications withother Aercon building systems,please consult an GeneralVII - Structural Design06/03 / VII-206/03 / VII-3 VII - Structural DesignB.
2 Floor PanelsGeneralThere are a number of reasonsfor choosing autoclaved aerat-ed concrete floors. Considerthe low weight, for influences the size andweight of the foundation, sincea traditional floor weighs threetimes as much as its fire-resistant characteristicsfor Aercon are , the Aercon floor panelshave superior sound and ther-mal characteristics inherent toAERCON distinct advantage ofusing Aercon floor panels isthe speed of installation. Afloor area up to 40 ft2is easilyinstalled with one crane liftutilizing a well-trained panels are supplied onthe basis of Strength Class AC4and AC6. The maximum panellength is 20'-0". The standardpanel width is 2'-0".
3 A nominalpanel thickness of 8", 10" or 12"is available depending on theloading and span require-ments. Reinforcing is placed in key joints between panels for continuity and diaphragm - Structural Design06/03 / VII-4 Panel SystemFloor panels are tailor length, thickness andreinforcement are determinedbased on the building require-ments and specifications. Thestandard panel width is 2'-0".See the Overview Section forpanel profile Cutting and OpeningsAll panels may be cut and maycontain openings throughoutthe panel. However, the size,location and type of cut or open-ing should be coordinated withAERCON prior to the designphase to avoid any unnecessaryfield modifications.
4 The reason for this is that everyopening, notch or cut (round,rectangular, diagonal) causesadditional stress on the areaaround the potential cut. Anyadditional reinforcementrequirements can be taken intoaccount during the Design andfabrication CUTDIAGONAL CUTNOTCH CUT (FIELD CUT)NO LIMITNO LIMITRIPPING - FITTED PANELOPENING (FIELD CUT)1/3 WIDTH (MAX)1/3 WIDTH (MAX)12" (MIN)06/03 / VII-5 VII - Structural DesignPanel ThicknessThe thickness of Aercon floorpanels depends on the requiredspan and loads. The following typical loads maybe used for calculating the panelthickness. However, all panels aredesigned based on the projectrequirements, as specified by theDesign Professional.
5 Weight of the floor panel 39 pcf for AC4 49 pcf for AC6 Dead Loads Flooring 5 psf Ceiling/Mech. 10 psf Partition 20 psf Live Loads 40 psf for residential 50 psf for offices 80 psf for corridors 100 psf for egressFor non-standard loads andrelated questions, consult anAERCON Representative. Checkall local jurisdictional require-ments for any additional ordiffering required Design graph below shows repre-sentative spans for a range oflive loads. This graph may beused for the preliminary deter-mination of the thicknessrequired for a particularproject. Since floor panels areuniquely designed for a project,the maximum span for anindividual panel may deviatefrom the graphical allowable deflection ofAERCON floor panels, due tothe total load, is L/240.
6 Theallowable deflection for the liveload is L/360. SupportThe length of bearing requiredfor Aercon floor panels is 21/2"minimum. GroutingThe key joints at adjacent pan-els are filled with cement groutin order to provide a positivediaphragm shear Panels Span vs. Live Load (psf)Span (feet)12" 10" 8" Panel Thickness0 10 20 30 40 50 60 70 80 90 100 VII - Structural Design06/03 / VII-6 GeneralTo further enhance a building sroom climate, acoustic perfor-mance and thermal perfor-mance, an Aercon roof panelsystem is the best solution toattain all of these characteris-tics. Aercon roof panels can beinstalled on a slope or thermal effects, within thebuilding, from the summer andwinter temperatures are mini-mized.
7 Similar to Aercon floorpanels, Aercon roof panelsweigh less than other concreteroof systems. Therefore, areduction in the size and weightof the building foundation sys-tem may be distinct advantage ofusing Aercon roof panels is thespeed of installation. A roof areaup to 40 ft2 is easily installed withone crane lift utilizing a well-trained erection crew. The fire-resistant characteristics forAERCON are panels are supplied on thebasis of Strength Class AC4and AC6. The maximum panellength is 20'-0". The standardpanel width is 2'-0". A nomin-mal panel thickness of 8", 10"or 12" is available dependingon the loading and spanrequirements.
8 C. Roof PanelsHorizontal (flat) roof panel / VII-7 VII - Structural DesignPanel SystemRoof panels are tailor length, thickness andreinforcement are determinedbased on the building require-ments and specifications. Thestandard panel width is 2'-0".See the Overview Section forpanel profile Cutting and OpeningsAll panels may be cut and maycontain openings throughoutthe panel. However, the size,location and type of cut oropening should be coordinatedwith Aercon prior to thedesign phase to avoid anyunnecessary field modifica-tions. The reason for this is thatevery opening, notch or cut(round, rectangular, diagonal)causes additional stress on thearea around the potential additional reinforcementrequirements can be taken intoaccount during the Design andfabrication CUTDIAGONAL CUTNOTCH CUT (FIELD CUT)NO LIMITNO LIMITRIPPING - FITTED PANELOPENING (FIELD CUT)1/3 WIDTH (MAX)1/3 WIDTH (MAX)12" (MIN)VII - Structural Design06/03 / VII-8 Panel ThicknessThe thickness of Aercon roofpanels depends on the requiredspan and loads.
9 Also, the panel thickness maybe influenced by the thermal oracoustical insulation require-ments in conjunction with therequired dead and live following typical loads maybe used for calculating the panelthickness. However, all panels aredesigned based on the projectrequirements, as specified by theDesign Professional. Weight of the roof panel 39 pcf for AC4 49 pcf for AC6 Dead Loads Roofing15 psf Ceiling/Mech. 10 psf Live Loads Roof20 psfFor non-standard loads andrelated questions, consult anAERCON Representative. Checkall local jurisdictional require-ments for any additional ordiffering required Design graph below shows repre-sentative spans for a range oflive loads.
10 This graph may beused for the preliminarydetermination of the thicknessrequired for a particularproject. Since roof panels areuniquely designed for a project,the maximum span for anindividual panel may deviatefrom the graphical Panels Span vs. Live Load (psf)Span (feet)12" 10" 8" Panel Thickness 0 10 20 30 40 50 60 70 8006/03 / VII-9 VII - Structural DesignDeflectionThe allowable deflection ofAERCON roof panels, due tothe total load, is L/180. Theallowable deflection for the liveload is L/240. SupportThe length of bearing requiredfor Aercon roof panels is 21/2"minimum. GroutingThe key joints at adjacent pan-els are filled with cement groutin order to provide a positivediaphragm shear ShapesTraditional flat or sloped roofsare possible with Aercon roofpanels.