VIP400, VIP410 - Electrical Network Protection - Reference ...

VIP400, VIP410 . NRJED311206EN 03/2013. VIP400, VIP410 . Electrical Network Protection Reference Manual 03/2013. NRJED311206EN. The information provided in this documentation contains general descriptions and/or technical character- istics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.

2 NRJED311206EN 03/2013 The information provided in this documentation contains general descr iptions and/or technical character-istics of the performance of the products contained herein.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of VIP400, VIP410 - Electrical Network Protection - Reference ...

1 VIP400, VIP410 . NRJED311206EN 03/2013. VIP400, VIP410 . Electrical Network Protection Reference Manual 03/2013. NRJED311206EN. The information provided in this documentation contains general descriptions and/or technical character- istics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.

2 Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information that is contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.

3 When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to observe this information can result in injury or equipment damage. 2013 Schneider Electric. All rights reserved. 2 NRJED311206EN 03/2013. Table of Contents Safety Information .. 5. About the Book .. 7. Chapter 1 At a Glance .. 9. Introduction .. 10. Standard Operation .. 14. Chapter 2 Installation.. 17. Safety Precautions .. 18. Precautions .. 19. Equipment Receipt and Identification .. 20. Mounting/Assembly .. 21. Connectors .. 23. Connecting the VIP to the Current Sensors.

4 24. Connecting the VIP to the Mitop Trip Unit .. 25. Earthing .. 26. Connecting the Auxiliary Power Supply and Outputs O1 to O3 ( VIP410 ) .. 27. Connecting a Core Balance CT ( VIP410 ) .. 29. Connection of the External Trip Input ( VIP410 ).. 30. Connecting the Modbus Communication Port ( VIP410 ) .. 31. Connector Pinout.. 32. CSH120, CSH200 and GO110 Core Balance CTs .. 34. CSHU Core Balance CT .. 37. Chapter 3 Use .. 39. User-Machine Interface .. 40. Operation According to the Power Supply Mode .. 43. Operation.. 45. Setting .. 47. List of VIP400 Screens .. 51. List of VIP410 Screens.

5 56. Chapter 4 Functions and Parameters.. 63. General Principle.. 64. Definition of Symbols.. 65. Choice of Earth Fault Current Measurement Method ( VIP410 ) .. 67. Network Frequency .. 68. Phase Overcurrent Protection (ANSI 50-51) .. 69. Earth Fault Protection (ANSI 50N-51N) .. 75. Overcurrent Protection Tripping Curves .. 82. Harmonic 2 Restraint.. 93. Phase Overcurrent Cold Load Pick-Up (Cold Load Pick-Up I) ( VIP410 ).. 94. Earth Fault Cold Load Pick-Up (Cold Load Pick-Up Io) ( VIP410 ) .. 97. Thermal Overload Protection (ANSI 49 RMS) .. 100. Circuit Breaker Trip (Mitop Trip Unit Output).

6 109. External Trip ( VIP410 ).. 110. Phase Current Measurement .. 111. Earth Fault Current Measurement.. 112. Phase Peak Demand Current Values .. 113. Load Current History .. 114. Counting the Number of Trips on a Fault .. 115. Breaking Current History .. 116. Time-Tagged Record of Last 5 Events .. 117. Operating Language .. 119. Communication .. 120. Mitop Trip Unit Trip Circuit Supervision.. 122. Date and Time.. 123. Password.. 124. NRJED311206EN 03/2013 3. Display the Status of the Output Relays ( VIP410 ) .. 125. Display the Status of the External Trip Input ( VIP410 ) .. 126.

7 Watchdog Relay ( VIP410 ) .. 127. Indicator LEDs on the Front Panel.. 128. Fault Acknowledgement.. 130. Chapter 5 Custom Operating Mode .. 131. Introduction .. 132. Customizing Operation of the Mitop Trip Unit Output .. 133. Customizing the Output Relays ( VIP410 ) .. 135. Customization Associated with the Circuit Breaker .. 137. Chapter 6 Reliability .. 139. General Principle .. 140. Operation of the Self-test System .. 141. Chapter 7 Communication .. 143. At a Glance .. 144. Modbus Protocol .. 145. Commissioning and Diagnosis.. 147. Automatic Adaptation of the Configuration: AUTOGO.

8 149. Access to Data.. 150. Data Coding .. 151. Synchronization, Identification, Metering, Network Diagnosis and Test Zones .. 152. Remote Control Zone.. 155. Remote Control Order, Status Condition and Remote Indication Feedback Code Zone.. 157. Time-Tagged Events .. 160. Access to Remote Settings .. 164. Settings Table .. 166. Date and Time-Setting and Synchronization .. 174. Managing the Date and Time Using Function 43.. 175. Read VIP Identification .. 176. Chapter 8 Commissioning .. 179. Safety Precautions.. 180. Introduction .. 181. Settings .. 182. Checking VIP Operation.

9 183. Checking the Complete Protection Chain .. 185. Commissioning .. 188. Chapter 9 Maintenance .. 189. Preventive Maintenance .. 190. Pocket Battery Module.. 191. Troubleshooting Assistance.. 194. Removing the VIP .. 198. Replacing the VIP Battery .. 199. Chapter 10 Characteristics .. 201. Function Characteristics .. 202. VIP Default Settings.. 209. Technical Characteristics.. 211. Environmental Characteristics .. 215. Internal Operation .. 217. 4 NRJED311206EN 03/2013. Safety Information . Important Information NOTICE. Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it.

10 The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. PLEASE NOTE. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction and operation of Electrical equipment and its installation, and has received safety training to recognize and avoid the hazards involved.