VISTA-128BPT SERIES Data Sheet; VISTA® Partitioned ...

The vista -128 BPT is a powerful member of the Honeywellfamily of commercial alarm panels, integrating burglary, CCTVand access control functions. Many features are available thatextend the applications of the vista -128 BPT while simplifyingend-user vista -128 BPT and vista -128 BPTSIA are listed forresidential burglary, residential fire and commercial burglaryapplications (see agency listings in this document for more details). They are compatible with a wide range ofAlarmNet communications products for alarm reporting,uploading /downloading and remote features ( vista -128 BPT and vista -128 BPTSIA): Provides nine style-B hardwired zones Supports up to 119 additional zonesusing a built-in polling (V-Plex ,multiplex) loop interface Supports up to 127 wireless zonesusing up to two 5800 SERIES wirelessreceivers (fewer if using hardwireand/or polling loop zones) Provides one power-limited bell circuitdelivering (max) at 12 VDC Provides the ability to control eightseparate partitions independently,each functioning as if it had its ownseparate control Accommodates 150 user codes withseven authority levels Accommodates 32 keypad macrocommands per system Keeps a log of up to 512 events Supports up to 16 compatible two-wire smoke detectors on zone 1 Zone 7 may be used for keyswitcharming/disarming Integrates with

VISTA-128BPT SERIES Accessories AUXILIARY DEVICES • 4204 - Relay Module, four form C contacts • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 6220S - System Printer Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Single Relay/Zone Module

Tags:

  Manual, Series, Sheet, Data, Vista, Addressable, Pull, 128bpt, Vista 128bpt series data sheet, Manual pull

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of VISTA-128BPT SERIES Data Sheet; VISTA® Partitioned ...

1 The vista -128 BPT is a powerful member of the Honeywellfamily of commercial alarm panels, integrating burglary, CCTVand access control functions. Many features are available thatextend the applications of the vista -128 BPT while simplifyingend-user vista -128 BPT and vista -128 BPTSIA are listed forresidential burglary, residential fire and commercial burglaryapplications (see agency listings in this document for more details). They are compatible with a wide range ofAlarmNet communications products for alarm reporting,uploading /downloading and remote features ( vista -128 BPT and vista -128 BPTSIA): Provides nine style-B hardwired zones Supports up to 119 additional zonesusing a built-in polling (V-Plex ,multiplex) loop interface Supports up to 127 wireless zonesusing up to two 5800 SERIES wirelessreceivers (fewer if using hardwireand/or polling loop zones) Provides one power-limited bell circuitdelivering (max)

2 At 12 VDC Provides the ability to control eightseparate partitions independently,each functioning as if it had its ownseparate control Accommodates 150 user codes withseven authority levels Accommodates 32 keypad macrocommands per system Keeps a log of up to 512 events Supports up to 16 compatible two-wire smoke detectors on zone 1 Zone 7 may be used for keyswitcharming/disarming Integrates with WIN-PAK accesscontrol systems to provide increasedusers, event log and scheduling Supports V-Plex addressableVistaKey access control (up to eightdoors and 250 cards) Easily programmed and maintainedby Compass Windows-baseddownloader Supports up to 96 programmableoutputs Programmable to meet SIA falsealarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2010, order part numberV128 BPTSIA Supports up to six touchscreenAdvanced User Interface (AUI)devices (6272 or later) Smoke detector reset at keypad Quick exit Group bypass Arm faulted Event arming Carbon monoxide (CO) zonetype support Expanded high-speed RS-232capability for third party interface and automation Internet upload/download over AlarmNet GSM and/or IP communicators over the panel'skeypad (ECP) bus Ringback support for AlarmNetcommunicators (confirmation ofclosing report) 24-hour dialer test support forAlarmNet devices Supports V-Plex Smart Contactfeature for improved responsivenesson systems with many V-Plex zones Telco line cut detectionFEATURESVISTA-128 BPT SERIESPARTITIONED COMMERCIAL BURGLARYALARM CONTROL PANELSB asic Hardwired ZonesProvides nine style-B hardwired zoneswith the following characteristics.

3 EOLR supervision (optional for zones2-8) supporting or sensors(EOLR supervision required for fireand UL burglary installations) Individually assignable to one of eight partitions Up to 16 two-wire smoke detectors on zone 1 Four-wire smoke or heat detectors on zones 1-8 (power to four-wiresmoke detectors must be supervisedwith an EOL device). Listed forresidential fire Loop ExpansionSupports up to 119 additional zonesusing a built-in polling (V-Plex, multiplex)loop interface. Current draw can totalup to 128mA. Polling loop zones havethe following characteristics: Must use V-Plex devices Supervised by control panel Individually assignable to one of eight partitions Supports VSI Module Supports 4297 Expander Module Maximum wiring distance = 12,000 feet Wireless ExpansionSupports up to 127 wireless zonesusing up to two 5800 SERIES wirelessreceivers (fewer if using hardwireand/or polling loop zones).

4 Wireless zones have the followingcharacteristics: Supervised by control panel forcheck-in signals (except certainnon-supervised transmitters) Tamper protection for supervisedtransmitters Individually assignable to one of eight partitionsSchedulingProvides the following schedulingcapabilities: Open/close schedules (for control ofarming/disarming and reporting) Holiday schedules (allows differenttime windows for open/closeschedules) Timed events (for activation of relays,auto-bypassing and unbypassing,auto-arming and disarming, etc.) Access schedules (for limiting systemaccess to users by time) End user output programming mode(provides 20 timers for output control)Eight PartitionsProvides the ability to control eightseparate areas independently, eachfunctioning as if it had its own separatecontrol. Partitioning features include: A Common Lobby partition (1-8),which can be programmed to armautomatically when the last partitionthat shares the common lobby isarmed, and to disarm when the firstpartition that shares the commonlobby is disarmed A Master partition (9), used strictly toassign keypads for the purpose ofviewing the status of all eight partitionsat the same time (master keypads) All zones assignable to one of eight partitions Keypads assignable to one of eightpartitions or to Master partition 9 toview system status Ability to assign relays to one or alleight partitions Ability to display fire and/or burglaryand panic and/or trouble conditionsat all other partitions keypads(selectable option)

5 Individually programmable accountnumber, entry delay and exit delay by partitionVISTA-128 BPT SERIESPARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS4293SN AdaptersVISTA-128 BPT4101 SNRelay ModuleFG1625SN Glassbreak4208EX Eight-zoneV-Plex Expander and4208SN Serialized Eight-zoneRemote Point Module710 StrobeLight748 Hor n5881 WirelessReceiver6160 Console4204 RelayModulePhone Line to Central StationGSMViGSMVorNotification AppliancesKeyswitchOption41465193 SERIES Smoke DetectorsV-Plex LoopPC ConnectionSerial PrinterRS-232DT7500SN V-Plex DUAL TECM otion SensorNOTE: Please refer to the website ( ) for the latest product BusorADDITIONAL FEATURESVISTA-128 BPT SERIESPARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELSA uxiliary Devices 4204 - Relay Module, four form C contacts 5881 SERIES - RF Receiver supporting5800 wireless detectors 6160 - Alpha Keypad/Annunciator 6220S - System Printer manual pull Stations 5140 MPS-1 5140 MPS-2V-Plex ( addressable ) Devices 4101SN Single Relay/Zone Module 4190SN Remote Point Module - two zones 4193SN Two-zone Serial InterfaceModule 4208EX - Eight-zone expander forULC commercial installations 4208SN Loop Expansion Module -eight zones 4209U Group Zoning Module -two/four zones 4293SN One-zone Serial Interface Module 4297 Isolation/Extender Module VSI Short/Overload Isolation Module 5193SD 5193 SDTP assive Infrared Detectors IS2500SN DT7500 SNV-Plex ( addressable )

6 Contacts 4939SN-WH 4944SN-WH 4959 SNV-Plex Glassbreak Detectors FG1625 SNVISTA Interactive Phone Module 4286 VIP ModuleOptional Communicators AlarmNet Internet/Intranetcommunicators and digital cellularcommunicatorsAccess Control VISTAKey V-Plex ( addressable ) Access Control VISTAKey-SK Starter Kit VISTAKey-EX Expansion KitWireless Devices 5804 - Wireless Key 5804BD - Bidirectional Key 5804 BDV - Bidirectional Key with voice 5816 - Door/Window Transmitter 5819 - Shock Sensor 5827BD - Bidirectional Keypad 5853 - Glassbreak Detector 5898 - Wireless DUAL TEC Motion Sensor 5800 PIR-OD - Outdoor Motion Sensor 5870 API - Asset Protection Device 5800 PIR/5800 PIR-RES/5800 PIR-COM- Wireless Motion Detectors 5800CO (5800 COA - Canada) -Wireless Carbon Monoxide Detector 5800RP - Wireless Repeater 5808W3 (5808W3A - Canada) -Wireless Smoke Detector 5809 - Wireless Heat DetectorCommercial Listed Wireless Devices 5817CB - Commercial UL Burglary,Universal Contact MonitoringTransmitter* 5869 - Commercial UL Wireless Hold-up Button* 5881 ENHC and 5883H Receivers*When used with 5881 ENHC and/or 5883H Detectors4944 SNContact5881 ENHCC ommercial Wireless Receiver(Max Two)4204 RelayModuleSupports Up To 16 Conventional Two-WireSmoke Detectors4209 UGroup ZoningModule4190 SNRemote Point Module4193 SNTwo-zone Serial Interface Module4959 SNOverhead Door ContactIS2500 SNV-Plex PIRM otion Sensor4208 UEight-zoneExpansion ModuleECP Bus5808W3(5808W3A - Canada)

7 WirelessSmoke Detector5800 PIR SeriesWireless PIRs5816 Door/WindowTransmitter5800 SeriesWirelessDevicesVISTAKey V-PlexAccess ControlModule5817CB UniversalContact MonitoringTransmitter5869 Commercial ULWireless Hold-upButtonORDERING vista -128 BPT Commercial Burglary Alarm Control Panel (UL Listed)V128 BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed)V128 BPTCNKT vista -128 BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)L/VSTA128 BPTD/D April 2011 2011 Honeywell International Inc. For more and Control SolutionsHoneywell Security & Communications2 Corporate Center Dr. Suite Box 9040 Melville, NY SERIESPARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELSA gency Listed to the Following Standards: UL609 Grade A Local MercantilePremises and Mercantile Safe and Vault UL1610 Grades A, AA Central Station UL365 Grades A, AA Police Connect UL985 Household Fire UL1023 Household Burglar AlarmCalifornia State Fire Marshall (CSFM) UL1635 - Digital AlarmCommunicator System Units CAN/ULC - S303 CAN/ULC - S304 CAN/ULC - S545 CAN/ULC - S1023 For commercial burglary attack proof requirements, use N5873V4 BEattack proof enclosure provided inVISTA-ULKT kitElectrical Voltage Input: From Honeywell Plug-In Transformer or1361X10 transformer (for X-10installations) rated , 40 VA Use 1361CN plug-in transformerfor Canada Alarm Sounder Output: , amps max.

8 ,(UL1023, UL609 installations);750mA less aux. current draw(UL985 installations) Auxiliary Power Output: , 750mA max. For ULinstallations, the accessoriesconnected to the output must be ULListed, and rated to operate in theabove voltage range Backup Battery: 12 VDC, 4AH or 7 AHsealed-lead acid. YUASA NP4-12(12V, 4AH) or NP7-12 (12V, 7AH)recommended Standby Time: Four hours min. with 750mA aux. load using 7AH battery Circuit Protectors: PTC circuitbreakers are used on battery input toprotect against reverse batteryconnections and on alarm sounderoutput to protect against wiring faults(shorts). A solid state circuit breakeris used on auxiliary power output toprotect against wiring faults (shorts).Main Dialer Formats Supported: ADEMCOC ontact ID with support for four-digitand ten-digit accounts andADEMCO 4 + 2 Express Line Seize: Double Pole Ringer Equivalence: Dimensions12-1/2" W X 14 1/2" H X 3" DSPECIFICATIONS