Example: marketing

VISTA-21iP, Data Sheet, Honeywell Security - …

VISTA-21iP. CONTROL PANEL. Honeywell 's high capacity, feature-rich VISTA-21iP lets you to and from the control panel. When used with an optional deliver more value to your customers on each and every AlarmNet GSM that snaps right on the board, the VISTA-21iP. sale. The VISTA-21iP provides up to 48 zones of protection, can be installed in premises without TELCO lines guaranteeing an on-board IP connection, graphic keypad support and communication independent of any infrastructure. The panel's dual partitions. The VISTA-21iP gives you the ability to send installation advantages, innovative end-user benefits and alarm signals and upload/download via an Internet Protocol robust system capacity make the value-priced VISTA-21iP. (IP), improving the speed at which information can be delivered an ideal choice for higher-end installations. FEATURES. Internet alarm reporting and 16 output devices Dynamic Signaling uploading/downloading capability Relays (Model 4204 Relay Modules, Reduces redundant reporting to via on-board AlarmNet Internet or 4229 Expansion Module), and/or the central station when multiple Communicator X-10 devices (when used with a reporting methods are used.)

Honeywell’s high capacity, feature-rich VISTA-21iP lets you deliver more value to your customers on each and every sale. The VISTA-21iP provides up to 48 zones of protection,

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of VISTA-21iP, Data Sheet, Honeywell Security - …

1 VISTA-21iP. CONTROL PANEL. Honeywell 's high capacity, feature-rich VISTA-21iP lets you to and from the control panel. When used with an optional deliver more value to your customers on each and every AlarmNet GSM that snaps right on the board, the VISTA-21iP. sale. The VISTA-21iP provides up to 48 zones of protection, can be installed in premises without TELCO lines guaranteeing an on-board IP connection, graphic keypad support and communication independent of any infrastructure. The panel's dual partitions. The VISTA-21iP gives you the ability to send installation advantages, innovative end-user benefits and alarm signals and upload/download via an Internet Protocol robust system capacity make the value-priced VISTA-21iP. (IP), improving the speed at which information can be delivered an ideal choice for higher-end installations. FEATURES. Internet alarm reporting and 16 output devices Dynamic Signaling uploading/downloading capability Relays (Model 4204 Relay Modules, Reduces redundant reporting to via on-board AlarmNet Internet or 4229 Expansion Module), and/or the central station when multiple Communicator X-10 devices (when used with a reporting methods are used.)

2 Supports four graphic 4300 Transformer) digital dialer and AlarmNet radio touchscreen keypads Four installer-configurable zone types allows the installer to create Valuable End-User Features Wireless keys can be programmed without using zones custom zone types by assigning Viewable on system keypads: all zone attributes Exit countdown Eight on-board hardwired zones standard (15 when Zone Doubling Supports four-wire, and up to Time and date display*. feature is used) 16 two-wire smokes Event log*. 40 hardwired expansion zones Works with Sentrol CleanMe Auto keypad backlighting on entry 40 wireless expansion zones maintenance signal Keyswitch arming Two low current on-board Multiple actions on output devices Programmable macro buttons and trigger outputs depending on system state single-button arming Turns lights off when system arms 100 Event Log viewable at system Supports a variety of wireless remote Turns the same light on keypads with time/date stamp controls for single-button operation when system disarms 48 system user codes assignable Flashes same lights when system User Scheduling to either partition is in alarm Automatically activates X-10 and Expandable to 48 total zones when Built-in phone line cut monitor relays at programmed times used with hardwired and/or wireless with programmable delay and Latchkey reports to pagers expansion modules annunciation options Auto arm/disarm Two independent partitions plus a Display on system keypads

3 User access time windows common partition Trigger local sounders Supports up to four end-user Global arming from any Trigger system bell numeric pagers system keypad VIP Module allows system control Goto function to view or operate Security Dealer Features from any touchtone phone one partition from the other Automatic System Load Shed Chime by zone Separate partition account numbers During extended AC power fail, the system battery will be disconnected to prevent irreversible *Requires custom alpha keypad battery failure. Reduces service calls to replace batteries. VISTA-21iP. CONTROL PANEL. SPECIFICATIONS. Electrical 5881 ENL RF Receiver supports Standard for Safety for Digital Alarm Aux. power 12 VDC, 600mA maximum up to eight zones 60mA Communicator System Units . 5881 ENM supports up to ANSI/UL 1635, 1996 (3rd edition). Seven hour standby at 400mA aux. load with four amp hour battery 16 zones 50mA Safety of Household Burglar Alarm 5881 ENH up to 48 zones 50mA System Units, ANSI/UL 1023, issued transformer 1996/11/25 (6th edition) with revisions Alarm output 12 VDC, amps max.

4 5883H High Security Transceiver up to 12/30/04. For agency listed installations, Module supports up to 48 zones . 80mA Commercial Burglary: combined aux. and alarm output cannot exceed 700mA Supports Eagle 1225 and 1221 boards Standard for Safety for Police Station Connected Burglar Alarm Units and Output Control Keypads Systems ANSI/UL 365 (4th edition), issued 1997/01/31 with revisions up Supports up to four relay boards 6160 Custom Alpha to 2005/03/08. (up to 16 relays) (required for programming). 100mA Standard for Safety Local Burglar Optional X-10 transformer/interface Alarm Units and Systems UL 609. (part no. 4300) may be used to control 6160V Custom Alpha Voice (11th edition), issued1996/08/28 with up to 16 X-10 receiving devices 100mA. revisions up to 2005/03/17. 6150 Fixed English LCD. Zones Standard for Safety Central Station 85mA/40mA. Eight hardwired zones Burglar Alarm Units ANSI/UL 1610. 6150V Fixed English Voice LCD (3rd edition), issued 1998/10/26 with (15 with zone doubling) 85mA/40mA revisions up to 2005/08/16.

5 Selectable response 10msec, 6150RF Fixed English RF LCD. 350msec, 750msec 85mA/40mA Communications Assignable to any partition 6148 Fixed English LCD VISTA-GSM Snap-in Dual-Path Digital 20 selectable zone types plus four 70mA/30mA Wireless Communicator (IP required configurable zone types for activation and registration). 6270 Graphic Touchscreen Programmable swinger suppression User Interface Touchtone or pulse standard TELCO. dialers 6271C Color Graphic Touchscreen Expansion Devices Formats supported User Interface 4219 Eight hardwired zones 16mA ADEMCO Contact ID. 6271CV Color Graphic Touchscreen 4204 Up to four relays 15mA ADEMCO 4 + 2 Express User Interface with Voice standby (each active relay ADEMCO low speed 8132 Symphony Advanced User Sescoa/Radionics draws an additional 40mA). Interface 4229 Eight hardwired zones and two 3 + 1, 4 + 1 and 4 + 2 reporting relays 36mA (each active relay Agency Listings Reporting capabilities draws an additional 40mA) ETL listing Split Dual Accessories Residential Fire and Burglary: Split/Dual True dial tone detection VISTA-GSM Snap-in Dual-Path Digital Household Fire Warning System Low battery reports Wireless Communicator (IP required Units ANSI/UL 985, 2000/05/26.)

6 (5th edition) with revisions up to AC loss and restoral reporting supported for activation and registration). 2004/04/29. 4286 VIP Voice Module 220mA. ORDERING. VISTA-21iP Control Panel VISTA-21iPSIA Control Panel for SIA Installations VISTA-GSM Optional Snap-in Radio Module VISTA-ULKT Cabinet for Listed Commercial Burglary Applications Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100. Box 9040. Melville, NY 11747 L/VS21iPD/D. August 2008. 2008 Honeywell International Inc.