Voltage/Current Transmitters SC-1300

Voltage/Current Transmitters SC-1300 . SC-1302. mV, V, mA inputs Current/voltage outputs Input/output isolation (SC-1302). Optional pulse duration output Surface or rack mount High load output option The SC-1300 and SC-1302 accept SC-1300 Specifications SC-1302 Specifications voltage or current inputs and Inputs: Inputs: provide a current or voltage output. Input Input Impedance Voltage Current Current Input The SC-1302 provides isolation 0-1 VDC 2 M . between the input, output and Inputs Inputs Impedance*. VDC 2 M 0-100 mVDC 0, mA DC 5k . power for AC or isolated DC 1-5 VDC 5 M 0-200 mVDC 0,1-5 mA DC 1k . powered units. 0-1 mA 5000 0-500 mVDC 0, 2-10 mA DC 500 . 1-5 mA 1000 0-1 VDC 0, 4-20 mA DC 250 . 2-10 mA 500 VDC 0, 10-50 mA DC 100 . 4-20 mA 250 0, 1-5 VDC. 10-50 mA 100 0, 2-10 VDC.

7.39 SC-1300 Specifications Inputs: Input Input Impedance 0-1 VDC 2 MΩ 0.25-1.25 VDC 2 MΩ 1-5 VDC 5 MΩ 0-1 mA 5000Ω 1-5 mA 1000Ω 2-10 mA 500Ω 4-20 mA 250Ω

Tags:

  3100, Sc 1300

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Voltage/Current Transmitters SC-1300

1 Voltage/Current Transmitters SC-1300 . SC-1302. mV, V, mA inputs Current/voltage outputs Input/output isolation (SC-1302). Optional pulse duration output Surface or rack mount High load output option The SC-1300 and SC-1302 accept SC-1300 Specifications SC-1302 Specifications voltage or current inputs and Inputs: Inputs: provide a current or voltage output. Input Input Impedance Voltage Current Current Input The SC-1302 provides isolation 0-1 VDC 2 M . between the input, output and Inputs Inputs Impedance*. VDC 2 M 0-100 mVDC 0, mA DC 5k . power for AC or isolated DC 1-5 VDC 5 M 0-200 mVDC 0,1-5 mA DC 1k . powered units. 0-1 mA 5000 0-500 mVDC 0, 2-10 mA DC 500 . 1-5 mA 1000 0-1 VDC 0, 4-20 mA DC 250 . 2-10 mA 500 VDC 0, 10-50 mA DC 100 . 4-20 mA 250 0, 1-5 VDC. 10-50 mA 100 0, 2-10 VDC.

2 Note: Any of the above ranges can also be *For low input impedance, use SC-1326. zero based. Linear inverter available for all ranges. Ambient Temperature Effect: Voltage Input Impedance: For 25 F to 125 F (-4 C to 52 C) Greater than 5 M . F ( C) maximum Response Time: F ( C) typical Less than 400 mS (10-90%). Response Time: Ambient Temperature Effect: Less than 50 milliseconds (10-90%) (1-5 V input). Isolation: For 25 F to 125 F (-4 C to 52 C). 600 VAC or 1000 VDC input/power F ( C) maximum isolation for AC or isolated DC powered F ( C) typical units Isolation: Input/output/power is 600 VAC of 1000. VDC for AC or isolated DC powered units. AMETEK. Signal Conditioning Output Signals: Power Supplies: High Load Drive Option (HO): a. 115 VAC 20%, 50/60 Hz, 5 watts mA Output Drive Capability mA Output Drive 10-50 mA 320.

3 (standard). Capability 4-20 mA 800 b. 24 VDC 20%, watts (H suffix; 10-50 mA 600 . 2-10 mA 1600 non-isolated) 4-20 mA 1600 . 1-5 mA 3200 c. 230 VAC 20%, 50/60 Hz, 5 watts 2-10 mA 3200 . mA 16,000 (H2 suffix) 1-5 mA 6400 . VDC Output Impedance d. 115 VAC 10%, 60 Hz, 5 watts, (H3 mA 32,000 . 2-10 VDC 500 suffix; P-11 or A-12 option) Note: any analog output may also be 1-5 VDC 250 e. 115 VAC 10%, 50/60 Hz, 5 watts zero based VDC 50 (H4 suffix; P-11 or A-12 option) True Voltage Output Option (VO): 0-100 mVDC 5 f. 230 VAC 10%, 50/60 Hz, 5 watts 0-10 mVDC (H5 suffix; P-1 or A-12 option) VDC Minimum Drive Impedance Note: Any of the above ranges can also be g. 24 VDC 20%, watts (I suffix; 0-10 VDC 300 . zero based isolated) 0-5 VDC 150 . Linearity: of span, maximum h. 48 VDC 20%, 5 watts, (I1 suffix; Agency Approvals: FM approved for error; except SC-1300L and SC-1300U isolated) ordinary locations and hazardous Repeatability: of span, Controls: Multiturn zero and span locations Divisions I and 2, Class 1, maximum error potentiometers Groups C Class II, Groups E, F &.

4 G. Explosion-proof housing required for Ambient Temperature Range: Net Weight (Approximate): hazardous locations. 0 to 140 F (-18 to 60 C) lbs. ( kg). Power Supply Effect: for a Enclosures: CSA approved for ordinary locations for 20% power variation maximum with a. single unit surface mount (standard) SC-1300 and SC-1302 with either 117. 800 ohm load and 4-20 mA output b. P-11, high density, 19" rack mount VAC, 24 VDC isolated or 24 VDC non- (H3, H4, H5 options 10%) (with rear access terminal blocks) isolated power versions. Common Mode Rejection: c. A-12, high density, 19" rack and 130 dB at 60 Hz surface mount (with front access terminal blocks). d. NEMA 4 and 12 (from one to 24 Ordering Information: units) see page , e. explosion-proof single unit, FM. approved for Class 1, Division 1, Groups C and D Dimensions: see page SC-1300 /02 SC-1302-P.

5 INPUT ( ) 1. INPUT (+) 2. 4. OUTPUT ( ) 5. OUTPUT (+) 6. 7. K2. 8. AC ( FOR DC) 11. POWER. 12 INPUT. AC (+ FOR DC). EARTH G.


Related search queries