Voyager™ II Rooftop Units - Trane-Commercial

RT-PRC014-E4_0513:BAT2 13:53 Page 1. Voyager II. Rooftop Units Cooling-only TKD-TKH 155-175-200-250-265-290-340. Heat pump WKD-WKH 125-155-200-265-290-340. Cooling-only with gas-fired heating YKD-YKH 155-175-200-250. Heat pump with gas-fired heating DKD/DKH 125-155-200-265-290-340. R410A Refrigerant RT-PRC014-E4. RT-PRC014-E4_1112:BAT2 11:01 Page 2. 2013 trane RT-PRC014-E4. RT-PRC014-E4_1112:BAT2 11:01 Page 3. Contents Features and Benefits 4. Options and Accessories 7. Selection Procedure 11. General Data 12. Sound Levels 16. Electrical Data 18. Dimensions and Weights 19. Controls 20. Mechanical Specifications 24. RT-PRC014-E4 3. RT-PRC014-E4_1112:BAT2 11:01 Page 4. Features and Benefits Figure 1 - High performance Scroll The Micro requires no special tools to The negative pressure gas valve will not compressor run the unit through its paces. Simply allow gas flow unless the combustion place a jumper between Test 1 and Test blower is operating.

Features and Benefits 4 RT-PRC014-E4 • The Micro requires no special tools to run the unit through its paces. Simply place a jumper between Test 1 and Test 2 terminals on the Low Voltage Terminal

Tags:

  Unit, Trane, Rooftop, Rooftop units

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Voyager™ II Rooftop Units - Trane-Commercial

1 RT-PRC014-E4_0513:BAT2 13:53 Page 1. Voyager II. Rooftop Units Cooling-only TKD-TKH 155-175-200-250-265-290-340. Heat pump WKD-WKH 125-155-200-265-290-340. Cooling-only with gas-fired heating YKD-YKH 155-175-200-250. Heat pump with gas-fired heating DKD/DKH 125-155-200-265-290-340. R410A Refrigerant RT-PRC014-E4. RT-PRC014-E4_1112:BAT2 11:01 Page 2. 2013 trane RT-PRC014-E4. RT-PRC014-E4_1112:BAT2 11:01 Page 3. Contents Features and Benefits 4. Options and Accessories 7. Selection Procedure 11. General Data 12. Sound Levels 16. Electrical Data 18. Dimensions and Weights 19. Controls 20. Mechanical Specifications 24. RT-PRC014-E4 3. RT-PRC014-E4_1112:BAT2 11:01 Page 4. Features and Benefits Figure 1 - High performance Scroll The Micro requires no special tools to The negative pressure gas valve will not compressor run the unit through its paces. Simply allow gas flow unless the combustion place a jumper between Test 1 and Test blower is operating.

2 This is one of our 2 terminals on the Low Voltage Terminal unique safety features. Board and the unit will walk through its The forced combustion blower supplies operational steps automatically. The a gas-air mixture through a single unit automatically returns control to the stainless steel burner screen into a zone sensor after stepping through the sealed drum where ignition takes place. test mode a single time, even if the It is more reliable to operate and jumper is left on the unit . maintain than a multiple burner As long as the unit has power and the system. LED is lit, the Micro is operational. The The hot surface ignitor is a gas ignition light indicates that the Micro is device which doubles as a safety device functioning properly. utilizing a continuous test to prove the The Micro features expanded flame. diagnostic capabilities when utilized Weather Tight Top and C abinet with trane 's Integrated Comfort.

3 Systems. Voyager Units incorporate the trane - Tite-Top (T3 ). Each part of the top The Micro in the Voyager Units has built- (three pieces) overlaps in such a way in anti-short-cycle timers, time delay that water cannot leak into the unit . relays and minimum ''on'' time controls. These overlapped edges are gasketed These controls are functions of the Micro and sealed to ensure superior water and are factory tested to assure proper integrity. Compressors operation. Quick- Access panels reduce the Voyager contains the best Scroll The Micro softens electrical ''spikes'' by number of possible water entry points. compressor technology available, in staging on fans, compressors and order to achieve the highest heaters. For added water integrity, Voyager has performance possible. The trane a raised 30 mm lip around the supply The Intelligent Fallback or Adaptive Voyager Rooftop has among the best and return of the downflow Units to Control is a benefit to the building COP in its class.

4 All performances are prevent water from blowing into the occupant. If a component goes astray, Eurovent certified which provides the ductwork. the unit will continue to operate at assurance of accurate performance and Quality And Reliability predetermined temperature set points. common comparison criteria Intelligent Anticipation is a standard The fan and idler arm assembly ReliaTel Micro Controls designs have been tested to over feature of the Micro. It functions The Micro provides unit control for constantly as the Micro and zone 300,000 cycles each. heating, cooling and ventilating sensor work together in harmony to All of Voyager's designs were utilizing input from sensors that provide tighter comfort control than rigorously rain tested at the factory to measure outdoor and indoor conventional electro-mechanical ensure water integrity. temperature. thermostats.

5 We perform a 100% coil leak test at the The Micro improves quality and Drum And Tube Heat Exchanger factory. The evaporator and condenser reliability through the use of timetested coils are leak tested at MPa and The drum and tube heat exchanger is microprocessor controls and logic. pressure tested to MPa. designed for increased efficiency and - prevents the unit from short cycling, reliability and has utilized improved Every unit and its options receive a considerably improving compressor technology incorporated in the large 100% unit run test before leaving the life. Rooftop commercial Units for almost production line to make sure it lives up - ensures that the compressor will run 20 years. to trane r equirements. for a specific amount of time which allows oil to return for better The heat exchanger is manufactured lubrication, enhancing the reliability using aluminized steel with stainless of the compressor.

6 Steel components for maximum - reduces the number of components durability. The drum and tube design has required to operate the unit , thereby been tested and passed over reducing possibilities for component 150,000 cycles. failure. 4 RT-PRC014-E4. RT-PRC014-E4_1112:BAT2 11:01 Page 5. Features and Benefits Figure 2 - Idler arm assembly Ease Of Installation Power factor of the fan motor is corrected and inrush current is very low Voyager Units provide many time and thanks to progressive fan ramp up start money saving features. (by default: 1 minute ramp up time). Conversionless Units Reduced maintenance costs with: The dedicated design Units (either Almost no maintenance direct coupling downflow or horizontal) require no compared to belt drive. panel removal or alteration time to convert in the field. Easy commissioning with adjustment of nominal airlfow and ramp up time for Horizontal Units come complete with progressive textile duct inflation.

7 Duct flanges so the contractor doesn't have to field fabricate them. Serviceability Improved Airflow Voyager's Simpler Design U-shaped airflow allows for improved The Voyager design uses up to 42%. static capabilities. fewer parts than previous Units . Since Single Side Access it is simpler in design, it is easier to diagnose. No more than three screws must be removed to access components. Reliatel trane 's Idler Arm Assembly Reliatel requires no special tools to run the Voyager unit through its paces. On most Units , our idler pulley provides Simply press the Test button located quick- adjustment for belt or motor on the right side of the control panel sheaves. No longer does one have to and the unit will walk through its adjust the motor to tighten the belt or operational steps automatically. change the motor sheave setting. As long as the unit has power and Variable Speed Direct Drive the LED is lit, Reliatel is operational.

8 The light indicates that the Micro is Supply Fan functioning properly. Efficient, flexible and low maintenance Reliatel features expanded diagnostic Figure 3 - RTRM (ReliaTel Refrigeration direct driven fan capabilities when utilized with trane 's Module). High efficiency fan Integrated Comfort TM Systems. Direct transmission, variable speed drives One Zone Sensor option has central delivers energy saving through 3 aspects: control panel lights which indicate the mode the unit is in and possible Higher fan nominal efficiency: The pulley diagnostic information (dirty filters no longer penalizes the airflow stream for example). at the an inlet, resulting in less turbulence and higher fan static efficiency. Standardized Components Direct coupling drive efficiency: The Components are placed in the same direct coupling concept avoids losses by location for all Voyager Units .

9 Belt friction. Classic belt drive is depletes Easy Access Lo w Voltage Terminal part of the motor power caused by Board improper belt tension, pulley mis- alignment. The direct driven fan improves The thermostat wires must be Figure 4 - Variable speed direct drive motor consumption by about 15% to connected to the terminals located on supply fan 20% compared to belt driven fan. the main board. Reduction of power input with fan speed Single Point Power modulation at part load or in ventilation A single electrical connection powers mode. Substantial energy savings can the unit . be achieved by reducing fan speed by only 20%, resulting in 20% less airflow and 50% less absorbed power. On a typical application, the result is an annual energy saving of 30% of the total Rooftop consumption. RT-PRC014-E4 5. RT-PRC014-E4_1112:BAT2 11:01 Page 6. Features and Benefits Figure 5 - RTOM (ReliaTel Option An Answer to Market Intelligent Anticipation is a standard Module) feature of Reliatel.

10 It functions Needs constantly as Reliatel and zone sensor Capacity Modulation work together in harmony to provide Voyager features dual Scroll tighter comfort control than compressor Units . The dual compressor conventional electro-mechanical models are outstanding for humidity thermostats. control, light load cooling conditions Downflow And Horizontal Economizers and system back-up applications. Economizers come with a comparative Low Ambient Cooling enthalpy control. All Voyager Units have cooling trane Communication Interface or TCI-R. capabilities down to -18 C as standard. is available factory installed. This module Flexible Applications when applied with the Micro easily interfaces with trane 's Integrated Thanks to its high static pressure Comfort TM System. capabilities, the Voyager can replace an older machine with old ductwork and, trane Modbus Communication Interface in some cases, improve the comfort (PIC) is an accessory that interfaces with through better air distribution.