Example: bachelor of science

WAS / WYS Series - pdhvac.com

DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. WAS / WYS Series WAS: Cooling Only Version WYS: Cooling and Heating Version Inverter+ and Inverter++ Models For 9,000-36,000 BTU/hr Systems WiFi Ready installation manual CS78421-548-754. IMPORTANT NOTICE: Please read this manual car efully before installing or operating your new air conditioning system. Be sure to save this manual for future reference. Table of Contents installation manual 0 Safety 4. 1 6. 2 Indoor Unit installation 8. 3 Unit 10. 4 Indoor Unit 11. 1. Select installation 2. Attach mounting plate to 3.

Page 5 WARNING 6. For all electrical work, follow all local and national wiring standards, regulations, and especially this Installation Manual.

Tags:

  Manual, Installation, Installation manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of WAS / WYS Series - pdhvac.com

1 DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. WAS / WYS Series WAS: Cooling Only Version WYS: Cooling and Heating Version Inverter+ and Inverter++ Models For 9,000-36,000 BTU/hr Systems WiFi Ready installation manual CS78421-548-754. IMPORTANT NOTICE: Please read this manual car efully before installing or operating your new air conditioning system. Be sure to save this manual for future reference. Table of Contents installation manual 0 Safety 4. 1 6. 2 Indoor Unit installation 8. 3 Unit 10. 4 Indoor Unit 11. 1. Select installation 2. Attach mounting plate to 3.

2 Drill wall hole for connective 4. Prepare refrigerant 5. Connect drain 6. Connect signal 7. Wrap piping and 8. Connect indoor power 18. 9. Mount indoor 18. 5 Outdoor Unit 20. 1. Select installation 2. Install drain 21. 3. Anchor outdoor 22. 4. Connect signal and power 6 Refrigerant Piping 25. A. Note on Pipe 25. B. Connection Instructions Refrigerant 25. 1. Cut 25. 2. Remove 26. 3. Flare pipe 26. 4. Connect 27. MC MC. 7 Air 29. 1. Evacuation 29. 2. Note on Adding 8 Electrical and Gas Leak 31. 9 Test 32. 10 European Disposal 34. Safety Precautions Read and Understand Safety Precautions Prior to installation Improper installation due to negligence of instructions may result in serious damage or injury.

3 The magnitude of potential damages or injuries is classified as either a WARNING or a CAUTION. This symbol indicates that ignoring the related instructions may cause death, or serious injury. WARNING. This symbol indicates that ignoring the related instructions may cause moderate injury to nearby persons, and/or damage to your appliance or other property. CAUTION. This symbol indicates that you must never perform the action shown. WARNING. Do not power the system using an extension cable or smaller than specified gauge wiring. Do not share the electrical circuit with other appliances.

4 Improper or insufficient power supply can cause undesirable operation, fire, or electrical shock. When connecting refrigerant piping, do not let any substances or gases other than the specified refrigerant enter the unit. The presence of other gases or substances will lower the unit's capacity, and can cause abnormally high pressure in the refrigeration cycle. This can also cause explosion and injury , as well as permament equipment failure. Remember : No dust, humidity or air should be allowed to enter. Do not allow children to play with or around the air conditioner.

5 Children near the unit must be supervised at all times. 1. installation must be performed by a licensed and trained technician. Defective installation can cause water leakage, electrical shock, or fire. The usage of proper tools is a requirement. 2. installation must be performed according to the installation instructions. Improper installation can cause water leakage, undesired performance, electrical shock, or fire. (In North America, installation must be performed in accordance with the requirements of NEC and CEC, by authorized personnel only.). 3. Contact a qualified and licensed HVAC technician for any repairs or maintenance of this unit.

6 4. Only use the included accessories, parts, and specified items for installation . Using non-standard parts can cause water leakage, electrical shock, fire, and can cause total unit failure. 5. Install the unit on top of a firm structure that can fully support it's weight. If the chosen location cannot support the unit's weight, or the installation is not done properly, the unit may fall and cause serious injury and damage. Page 4 . WARNING. 6. For all electrical work, follow all local and national wiring standards, regulations, and especially this installation manual .

7 You must use an independent circuit and a dedicated breaker to supply power. Do not connect other appliances to the same circuit. Insufficient electrical capacity or defects in electrical work can cause electrical shock or fire. 7. For all electrical work, use the specified cables. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminals. Improper electrical connections can overheat and cause fire, and may also cause shock. 8. All wiring must be properly arranged to ensure that the control board cover can close properly.

8 If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock. 9. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended. This is intended as a comfort cooling system. 10. If the supply cord is damaged, it must be replaced by a certified service agent or similarly qualified technicians, in order to avoid a hazard. 11. This appliance can be used by children aged 8 years and above, as well as persons with reduced physical, sensory, or mental capabilities, or lack of experience or knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way, and understand the hazards involved.

9 Children shall not play with or near the appliance. Cleaning and user maintenance shall not be done or attempted by children or untrained personnel without proper supervision. CAUTION. For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any combustible materials. Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the unit, it may cause fire. Do not operate your air conditioner in a highly humid space, such as bathrooms or laundry rooms. Exposure to high humidity or water can cause electrical components to short circuit.

10 1. The product must be properly grounded at the time of installation , else electrical shock may occur. 2. Install drainage piping according to the instructions in this manual . Improper drainage may cause water damage to your home and property. Note about Fluorinated Gasses 1. This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. 2. installation , service, maintenance, and repair of this unit must be performed by a certified HVAC. technician.