Example: tourism industry

Water Softener

Water SoftenerOperating ManualwatersourcewatersourceWater Softener Operating ManualWater Softener Operating ManualContents:1. Introduction2. Installation Instructions3. Settings4. Controller Features5. Trouble Shooting1. IntroductionThank you for choosing a Water Softener meticulously produced for you by Watersource. We take great care to ensure that you receive this product in the same perfect condition that it left us. An extensive testing program has been employed to guarantee the performance and reliability that you would expect from an appliance costing many times valve with which your Water Softener is fitted has been selected to provide the best balance possible for your requirements. Please identify your valve from the following to determine the correct set-up procedure. Time controlled ( ) Meter controlled (V)The plumbing requirements are identical for both types of softeners.

watersource watersource Water Softener Operating Manual 2. Installation Instructions A water softener is no more difficult than a dishwasher or washing

Tags:

  Softener, Water, Dishwasher, Water softener

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Water Softener

1 Water SoftenerOperating ManualwatersourcewatersourceWater Softener Operating ManualWater Softener Operating ManualContents:1. Introduction2. Installation Instructions3. Settings4. Controller Features5. Trouble Shooting1. IntroductionThank you for choosing a Water Softener meticulously produced for you by Watersource. We take great care to ensure that you receive this product in the same perfect condition that it left us. An extensive testing program has been employed to guarantee the performance and reliability that you would expect from an appliance costing many times valve with which your Water Softener is fitted has been selected to provide the best balance possible for your requirements. Please identify your valve from the following to determine the correct set-up procedure. Time controlled ( ) Meter controlled (V)The plumbing requirements are identical for both types of softeners.

2 There are 4 connections to make: Inlet, Outlet, Drain and : This is the Water supply from the mains or other : This is the treated Water leaving the Softener to supply the rest of the : This is the Water used during regeneration which is flushed to drain. This Water will be at mains pressure and must be taken directly to a : This is only used in the event of an over-fill of Water tothe salt cabinet. This should always be taken directly through thenearest wall to a point where it may be obvious low Water pressurebelow 20 psi, or a frozen drain line, is causing over-fill. A serviceenquiry can be made to discuss this particular Softener Operating Manual2. Installation InstructionsA Water Softener is no more difficult than a dishwasher or washing machine to install. However, it is advisable for the installation to be carried out by either a plumber or a competent , determine where the Water enters the house (usually under the Kitchen Sink).

3 Secondly, check to see that the Water softerer will fit the space available. Remember to leave sufficient space for connections to be made at the back. In some kitchens it may be necessary to remove part of the cupboard base to ensure sufficient head-room. In other cases it may make more sense to locate the Water Softener in an outside cabinet to maintain the space under the the ion exchange process used to soften Water results in a slight increase in the sodium level of the Water , it is often suggested to provide a lower sodium source of Water for infant feeds, aquaria, etc. Irish law & EU directives do not set regulations for low sodium pipe feeds within private households. Softened Water is often half of the 200 mg/L sodium EU are a number of ways to achieve this:Fit a Reverse Osmosis unit teed off a treated Water line. This has1. the benefit of giving a soft Water feed (free of Limescale) with low sodium and excludes virtually all undesireable contaminants, such as: fluoride, chlorine, aluminium, viruses, cysts (such as cryptosporidium), phosphates, pesticides, heavy metals and many more to %.

4 Fit an extra tap to the sink with either filtered or unfiltered raw 2. Water . This Water has not been treated and as such has only background Sodium the cold tap at the kitchen sink Once the above decisions have been made it is time to familliarise yourself with the hoses and fittings required to complete the Water Softener has been designed to operate at between and 5 Bar pressure. If your pressure falls outside these parameters it may be necessary to fit a booster pump or a Pressure Reduction Valve to prevent damage to the unit. The temperature range of the appliance is 0*C and 49* InstallationThe rising main is usually found under the sink. Once the stop-cock has been shut, open the cold Water tap at the kitchen sink. This will release the pressure in the line. At this point, the pipe can be cut to allow fitment of the non-return valve and the T complete with shut-off valve.

5 The next stage is to fit the by-pass valve and the outlet T for the return two washing machine valves provide the threaded connections for the washing machine hoses, which in turn connect to the inlet and outlet ports of the valve. The drain line also has a 3/4 bsp thread to allow a third washing machine hose to take the flow to overflow fitting must be connected to a hose dropping straight down and passing through the wall. This hose should always be visible to identify any discharge which would require a service the power supply and turn the machine powered-up, press the Regen button, or in the case of a Valve, press the up and down buttons and hold until you hear the the motor stops, open the inlet valve slowly to allow the Softener to fill. At this point the Softener is running to drain. This allows the resin to wash out any colour that may be motor will engage again after a set period and move on to the next stage.

6 When it stops, toggle it to the next stage by pressing the Regen button in the case of a metered unit, or by pressing the up arrow on the Unit. Continue this until the C4 ( ) or Rinse appears on the the unit to Rinse and Fill , approximately 8 minutes in total. Now you can see the Water level and fill with salt. When you fill with salt the Water will be displaced and will appear to be higher in the Softener Operating ManualAt this point the Water Softener is ready to give soft Water . Regenerations will be triggered on the basis of Water used or time elapsed depending on the To The SystemTo allow for connection to your plumbing system your new Water Softener is supplied with quick connect fittings for the inlet and outlet. These have an o ring seal to ensure leak-free connection time after time. The end connections are Bsp male, as is the drain line.

7 This means connections may be made with washing machine type hoses, or by hard plumbing in either or preferably, pipe. The quick connect fittings will allow for easy connection, whichever means you choose. Always remember with pex piping always use inserts when using compression or VolumetricPress Set Clock until display stops Press the Set Clock button, hours will flash. Use up & down 2. buttons to set Next button, repeat above to adjust Press Next and Up buttons together and hold until screen 4. Hardness then press Next button to scroll to Regen 5. Time Adjust as above and press Set Clock to exit menu. Set-up is now 6. Controlled ( )Press Set Hour until display stops Press Set Hour , adjust current time with arrows (hours only).2. Press Set Hour and up arrow together and Regen Hour will show. Adjust using Press Set Hour and Days to Regen will flash.

8 Adjust with 5. Set Hour until current time is shown. Set-up is now 6. Controller FeaturesMetered or VolumetricWhile in the service position, pressing the next button will toggle between the time, current flow rate in litres and the capacity force a regeneration a single press on the Regen button will cause the Softener to regenerate at the set time the following morning. Press and hold to force an immediate regeneration. When the valve is regenerating it will show a countdown clock for each valve shown openOutlet from softnerBy-pass valve shown closedInlet valve shown openInletfrommainsInlet to softnerNon-return valveInletOutletOverflowDrain LinewatersourcewatersourceWater Softener Operating Manual5. Trouble ShootingPROBLEM: Water STILL REMAINS HARD1. Is there a minimum of 6 inches of salt in the Brine Cabinet? Solution: Fill the cabinet with Is the bypass valve closed, and the inlet and outlet valves open?

9 Solution: Close the bypass valve and open the inlet and outlet Is the power on?Solution: Switch the power on and check the Is the hardness setting correct?Solution: Reset the hardness if : If any of the above requires action, add 5 litres of Water to the salt and initiate a REG (Regeneration).PROBLEM: NO WATER1. Is the Water mains open?Solution: Open the Water Are the inlet and outlet valves open?Solution: Open the inlet and outlet : UNIT REGENERATES AT THE INCORRECT TIME OF DAY1. Is the present time correct?Solution: Reset the present Is the recharge time correct?Solution: Reset the recharge Has there been a powercut?Solution: No action required if the time is : NO REGEN, OR LITTLE OR NO SALT USAGE1. Is the Water soft?Solution: If yes no action is Is the Water level in the brine cabinet high?Solution: If yes, check the drain line is not frozen or blocked. Initiate an immediate regeneration and check the progress of the cycle.

10 If the Water level approaches the overflow level, shut off inlet and arrange a service Press Next button to check remaining : If capacity remaining is still larger than 25% of full capacity press Regen button to force a : EXCESSIVE SALT USAGE1. Check the : Reduce the hardness setting if : NO Water IN THE BRINE CABINET1. Depending on the salt level you may not see the Water . This is quite normal. Only a few inches of Water are used. Solution: No action : HIGH Water LEVEL IN THE BRINE CABINET1. Is the Water level in the brine cabinet high?Solution: Initiate an immediate regeneration. If the problem does not return, further action is not : Water IS RUNNING FROM THE OVERFLOW1. Is the Water level in the brine cabinet approaching the height of the over-flow pipe?Solution: If yes, bypass the Water Softener and call for : Water IS RUNNING FROM THE DRAIN CONSTANTLY1. Is the unit in recharge mode?


Related search queries