Wet Gas Transmitter.. - Analytical Technology, Inc.

Gas ..Increasingly stringent air qualityrequirements have led to expandeduse of wet scrubber systems to controlair emissions. Chlorine storagefacilities and chemical process plantsare frequently required to scrubexhaust gas streams to removehalogen and acid , monitoring reactivegas concentrations in moisturesaturated air streams presentsproblems for standard diffusionsensors. Condensing water in these airlines can quickly blind diffusionsensors, rendering them s Series B12 Wet Gas Systemwas developed to meet the need forreliable measurements in wetscrubber outlets for other gas streamsthat might be saturated with watervapor. Systems have been developedfor monitoring strong oxidants(chlorine, bromine, chlorine dioxide,or ozone), acid gases (HCl or HF), basic B12 Wet Gas Systemconsists of a loop-powered 2-wiretransmitter and a corrosion resistantsensor specifically engineered tooperate at 100% RH.

SeriesB12 . Wet Gas Transmitter.. ..... Increasingly stringent air quality requirements have led to expanded use of wet scrubber systems to control

Tags:

  Transmitter, Wet gas transmitter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Wet Gas Transmitter.. - Analytical Technology, Inc.

1 Gas ..Increasingly stringent air qualityrequirements have led to expandeduse of wet scrubber systems to controlair emissions. Chlorine storagefacilities and chemical process plantsare frequently required to scrubexhaust gas streams to removehalogen and acid , monitoring reactivegas concentrations in moisturesaturated air streams presentsproblems for standard diffusionsensors. Condensing water in these airlines can quickly blind diffusionsensors, rendering them s Series B12 Wet Gas Systemwas developed to meet the need forreliable measurements in wetscrubber outlets for other gas streamsthat might be saturated with watervapor. Systems have been developedfor monitoring strong oxidants(chlorine, bromine, chlorine dioxide,or ozone), acid gases (HCl or HF), basic B12 Wet Gas Systemconsists of a loop-powered 2-wiretransmitter and a corrosion resistantsensor specifically engineered tooperate at 100% RH.

2 Sensors aredesigned for direct insertion into ventstacks, or may be used in a flowcell ifsample can be pumped to the remote display and alarmrelay functions are required, the B12 Wet Gas Transmitters can beconnected to ATI's B14 Alarm ReceiverSystem. This system will provide directdigital display of gas concentration,plus 3 alarm setpoints, remote alarmreset input, and retransmitted 4-20mA output. Or, the B12 transmittermay be used separately and tieddirectly to the users' DCS, PLC, orother equipment. Either way, the B12is an excellent solution to a difficultmonitoring a look at these features: Direct measuring sensor Minimal maintenance Rapid response Stack mount or flow-throughsensor transmitter LCD display option Loop-powered electronicsAccurate Gas Measurementin Wet Gas StreamsRepresented By:Gas Type:Oxidant gases: Cl2, Br2, ClO2, O3 Acid gases: HF, HClHydrogenRange:0-10, 0-20, 0-50, or 0-100 ppm foroxidant or acid gases.

3 0-2% or0-10% for :Generally 5% of value, but limitedby available calibration Repeatability: 1% of spanElectronic Linearity: of spanOutput:Loop-powered 4-20 mA, 675 ohmsmaximum at 24 VDCP ower:12-28 VDCE nclosure:NEMA 4X polystyrene, LCD displayoptional. Explosion-proof optional,Class 1, Div 1, Groups B, C, & :Zero and span potentionmetersmounted on transmitter circuitboardOperating temperature:0 to +50 CSensor materials:NorylSensor cable:25 feet standard, 100 :1 lb ( kg)Suffix CC - Gas Type69 - Oxidant gas (specify Cl2, Br2, O3, or ClO2)70 - Acid gas (specify HCl or HF)71 - HydrogenSuffix D - transmitter Type2 - Explosion-proof5 - Standard NEMA 4X noryl6 - NEMA 4X with LCD Gas ..SpecificationsOrdering Information: Model B12-CC-D-EEEE-FVent StackDouble Strap SaddleWet Stack Sensor1-1/4" MNPTB12 Transmitter25' Std Cable Length(Supplied by ATI)CustomerReadoutDevice+_240 VDCT ypicalInstallationAnalytical Technology, Iron Bridge Drive Collegeville, PA 19426 Phone: 610/917-0991 Toll-Free: 800/959-0299 Fax: 610/917-0992E-Mail: (UK) LimitedBank Chambers, 33 Stamford StreetMossley, Aston-u-Lyne OL5 0 LLPhone: +44 (0) 1457 832800 Fax: +44 (0) 1457 83950E-Mail: E - Measurement RangeCode the measurement range using a 4-digit specifications above for available ranges.

4 For example, a standard wet chlorine transmitter with a range of 0-10 ppmwould be coded 0010. A hydrogen system with a range of 0-2% would be coded 0002. Consult factory for availability ofspecial F - Units of Measurement1 - PPM3 - %Accessories00-0633 - Flowcell assembly/calibration adapterReceiver - Series B14 alarm system (see separate B14data sheet)