Transcription of Why Worry about Building Energy Performance?
1 12/18/2013. Improving Building Energy performance Illinois Chapter December 12, 2013. Thomas H. Phoenix, , FASHRAE. ashrae -Certified Building Energy Assessment and Building Energy Modeling Professional 2013-14 President-Elect Why Worry about Building Energy performance ? 1. 12/18/2013. Source: US Dept of Energy . 2011 Buildings Energy Data Book Source: US Dept of Energy 2011. Buildings Energy Data Book 2. 12/18/2013. Source: NBI Energy performance of LEED for New Construction Buildings Why Are Tools Needed? Can't manage what you don't measure. Claims of high performing buildings made but little evidence presented to verify Establish common set of measurements with results reported against meaningful and consistent benchmarks. Reliable and reproducible protocols needed to give usable feedback to designers/operators when measured performance does not match design intent and expectations 3.
2 12/18/2013. Tools for Improving Building Energy performance Standards, Guidelines and Special Publications eLearning Certification Building Energy Quotient (bEQ). Case Study: ashrae Headquarters Maintain to Sustain Modern air conditioning systems protect the health, comfort and productivity of Building occupants. Unfortunately, they consume a lot of Energy while providing these benefits. When these systems are not operated properly, the Energy they use can increase by 50 percent or more. The elimination of non- value producing Energy helps protect our environment while saving the Building owner money.. - ashrae Presidential Member William Harrison 4. 12/18/2013. Maintain to Sustain Reduction not so much the result of changes in hardware and systems. Reduction comes from improvements in software and operational training.
3 Study by the Energy Systems Lab at Texas A & M University indicated Energy use in buildings could be reduced by 10% to 40% by improving operational strategies in buildings. Over reliance on expert knowledge has resulted in minimum transfer of knowledge. Standards and Guidelines Guideline 32-2012, Sustainable, High performance Operation and Maintenance Provides guidance on optimizing O&M to achieve lowest economic and environmental life cycle cost without sacrificing safety or functionality Assists those who operate and maintain buildings to achieve high performance : safe, productive indoor environments; low economic life cycle cost; low Energy , water and resource use;. and low impacts on environment Applies to all buildings, not just new ones 5. 12/18/2013. Standards and Guidelines ANSI/ ashrae /ACCA 180-2008, Standard Practice for Inspection and Maintenance of Commercial- Building HVAC Systems, establishes minimum HVAC.
4 Inspection/maintenance requirements that preserve a system's ability to achieve acceptable thermal comfort, Energy efficiency and indoor air quality Standard 111-2008, Measurement, Testing, Adjusting and Balancing of Building HVAC. Systems Standards and Guidelines Guideline 0-2005, The Commissioning Process, describes commissioning process capable of verifying facility and systems meet owner's project requirements Guideline , HVAC&R Technical Requirements for the Commissioning Process, describes technical requirements for application of commissioning process in Guideline 0-2005. Guideline , The Commissioning Process for Existing Systems and Assemblies Guideline , The Commissioning Process for Existing HVAC&R Systems 6. 12/18/2013. Standards and Guidelines ashrae /IES Standard 202-2013, Commissioning Process for Facilities and Systems Purpose: identify minimum acceptable commissioning process for buildings and systems Scope: provides procedures, methods, documentation requirements for each phase of project delivery from pre-design through occupancy and operation phases, including: overview of Commissioning Process activities description of each phase's minimum activities acceptance requirements minimum training requirements Newly published Standards and Guidelines Standard 214P, Standard for Measuring and Expressing Building Energy performance in a Rating Program Purpose.
5 Provide a standardized approach and methodology for measuring and expressing Building Energy performance in rating programs standardize formats and labels associated with Building Energy rating programs establish minimum requirements for rating program documentation 7. 12/18/2013. Standards and Guidelines Standard 214P. Scope: new and existing buildings; Building sites on which buildings are located; all accessory structures; Energy using systems and equipment establishes requirements for disclosure of Building Energy use via rating labels and supporting summary documentation modeling of buildings and Building sites to estimate/predict Building Energy use requirements for measuring and expressing Energy use of buildings and Building sites that are in operation acceptable credentialing criteria for individuals applying standard and reporting Building Energy use preoccupancy and post-occupancy conditions format and content of rating disclosure, labels and supporting documentation performance Measurement Procedures for Commercial Buildings.
6 Best Practices Guide Tools, techniques for measuring, managing, improving facility performance Provides specific best practices for Energy use water use four elements of indoor environmental quality thermal comfort, indoor air quality lighting/daylighting acoustics Companion book to performance Measurement Protocols for Commercial Buildings 8. 12/18/2013. Advanced Energy Design Guides Collaboration of professional organizations AIA, USGBC, IES and DOE. Provide design packages and strategies to help owners and designers achieve 50% site Energy savings over ashrae 2004. Present climate specific recommendations by Building types Whole Building approach Opaque envelope and fenestration Daylighting and lighting HVAC and service hot water Plug and process loads Existing Building Guidance Set of two guidance documents Provides business case and technical guidance for Energy improvements Demonstrates how to benchmark performance against comparable buildings Illustrates how Energy use and cost can be reduced by up to 30.
7 Percent Developed with BOMA, AIA, USGBC, IES, GSA. 9. 12/18/2013. ashrae GreenGuide Covers need-to-know information what to do, what to suggest how to interact with other members of the design team in a productive way Updated version slated for January 2014. Indoor Environmental Quality Describes 40 strategies for achieving critical IAQ objectives related to moisture management, ventilation, filtration and air cleaning and source control. Highlights how design and construction teams can work together to incorporate good IAQ. strategies from initial design through project completion. Joint effort of ashrae , AIA, BOMA, EPA, SMACNA, USGBC. Free download at 10. 12/18/2013. New eLearning Website Simpler, more intuitive navigation: subscriptions and access to training landing page Single sign on for ashrae .
8 Members Simplified purchasing process More search tools: o Browse by course, course package or library o Filter by training level or subject Subscription Options Choose from variety of course packages, such as HVAC Systems or HVAC Control Systems Or pull individual courses from variety of course packages or libraries to tailor to specific training needs Introduction to HVAC Control Systems Sensors and Auxiliary Devices Control Diagrams and Sequences DDC Introduction to Hardware and Software DDC Networks and Protocols DDC Specification, Installation and Commissioning 11. 12/18/2013. Certification ashrae 's certification programs recognize industry professionals who have mastered the knowledge and skills reflecting best practices in certain aspects of Building design and operations.
9 Earning this recognized, high-quality industry certification can demonstrate your value to the design process and also serves as a springboard for continued professional development. ashrae has certified more than 1,600 HVAC&R professionals. Certification Building Energy Assessment Professional (BEAP). Building Energy Modeling Professional (BEMP). Commissioning Process Management Professional (CPMP). High- performance Building Design Professional (HBDP). Healthcare Facility Design Professional (HFDP). Operations & performance Management Professional (OPMP). 12. 12/18/2013. Commissioning Process Management Professionals ashrae 's most popular certification; introduced in 2009. Revision of exam completed in 2011; next revision slated for 2014 or 2015. Developed first online practice exam earlier this year Commissioning Process Management Professionals Helps Building owners, developers, operators recognize individuals capable of assuring Building systems and equipment are designed, installed, tested, operated and maintained according to their operational needs 523 Commissioning Process Management Professionals 13.
10 12/18/2013. Building Energy Assessment Professional (BEAP). Certifies ability to audit and analyze residential, commercial, and industrial buildings including: Determining project scope Collecting data Analyzing Building performance Interpreting results information Evaluating alternatives Recommending Energy conservation measures Assisting with ECM implementation Exam currently being updated 184 Building Energy Assessment Professionals Building Energy Modeling Professional (BEMP). Certifies ability to: Evaluate and choose Use and calibrate Interpret results of Energy modeling software when applied to Building and systems Energy performance and economics for new and existing buildings Exam updated in 2012. 290 Building Energy Modeling Professionals 14. 12/18/2013. Building Energy Labeling As the nation looks to reduce its Energy use, information is the critical first step in making the necessary choices and changes.