GOLD SERIES OIL BOILERW ater with Tankless Heater | Chimney Vent | 86-295 MBH Series 3 | Efficiency 85-87%**ENERGY STAR requires a minimum of 87% AFUE, which is only achieved by these models by reducing the burner rate and installing the optional vent damper kit. See Ratings chart on next page.*APPLICATIONS INCLUDE:ResidentialLight CommercialMultiple BoilersRadiant And Much MoreHIGH EFFICIENCY CAST IRON boiler Provides space and domestic hot water heating Durable cast iron heat exchanger design Made with Weil-McLain qualityNOTES:** Add P for packaged boiler ( wtgo -3 through wtgo -6 only). Add A for boiler only ( wtgo -3 through wtgo -9).

water per minute, heated from 40oF to 140 oF with 200 F boiler water temperature-tested in accordance with I-W-H Testing and Rating Standard for Indirect Tankless Water Heaters Test with Boilers. Factory Tested and Assembled Cast Iron Section Assembly (jacket and collector hood are not assembled on 7, 8 and 9 section blocks)

Tags:

  Water, Boiler, Lewis, Weil mclain, Mclain, Wtgo

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of WTGO - Weil-McLain

1 GOLD SERIES OIL BOILERW ater with Tankless Heater | Chimney Vent | 86-295 MBH Series 3 | Efficiency 85-87%**ENERGY STAR requires a minimum of 87% AFUE, which is only achieved by these models by reducing the burner rate and installing the optional vent damper kit. See Ratings chart on next page.*APPLICATIONS INCLUDE:ResidentialLight CommercialMultiple BoilersRadiant And Much MoreHIGH EFFICIENCY CAST IRON boiler Provides space and domestic hot water heating Durable cast iron heat exchanger design Made with Weil-McLain qualityNOTES:** Add P for packaged boiler ( wtgo -3 through wtgo -6 only). Add A for boiler only ( wtgo -3 through wtgo -9).

2 (1) No. 2 fuel oil-Commercial Standard Specification CS75-56. Heating value of oil-140,000 BTU / Gal.(2) Based on standard test procedures prescribed by the United States Department of Energy at combustion condition of CO2 and " draft.(3) MBH refers to thousands of BTU per hour.(4) AHRI gross output.(5) Net AHRI ratings are based on net installed radiation adequate for the requirements of the building, including a piping and pickup allowance of for normal conditions. Provide additional allowance only for unusual piping and pickup loads. (6) Tankless heater rating is in gallons of water per minute, heated from 40oF to 140oF with 200oF boiler water temperature-tested in accordance with I-W-H Testing and Rating Standard for Indirect Tankless water Heaters Test with Boilers.

3 Factory Tested and Assembled Cast Iron Section Assembly (jacket and collector hood are not assembled on 7, 8 and 9 section blocks) Tankless Heater (P-units) or Tankless Opening Cover Plate (A-units) Insulated Steel Jacket Aluminized Steel Flue Collector Hood with Flue Cap on Top Outlet (convertible to rear outlet) Swing-Away Burner Mounting Door Refractory Blanket and Target Wall in Combustion Area Circulator (when ordered) Sizes 3 4: Taco 007e Sizes 5 6: Taco 007 Comb. Temp. Controls, LWCO, Circulator Relay (all P-units/A-units ordered with tankless heater), and integrated service switch Two Vent Pipe Brackets Pressure / Temperature Gauge 30 PSI ASME Relief Valve ( boiler sections tested for 50 PSIG working pressure) Drain Valve Barometric Damper High-Efficiency Flame-Retention Oil Burner (Beckett AFG, Carlin EZ or Riello).

4 Specify 2-Stage Fuel Unit (optional) if Required Vent Damper Kit W-M 5 & 10 Year Homeowner Protection Plan W-M Indirect-Fired water Heaters OPTIONAL EQUIPMENT:A- wtgo FrontSideBackIntermediateDIMENSIONSSTAND ARD EQUIPMENT:ModelP-WGOA-WGOR eturnBLWTGO-3 wtgo -3 LWTGO-4 wtgo -5 wtgo -6 wtgo -7 wtgo -8 wtgo -9 Dimension (inches)1 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/21 1/213 3/416 7/82023 1/826 1/432 1/229 3/816 7/810 1/213 5/816 7/82023 1/829 3/826 1/413 1/2 Supply C (inches)(inches)NumberWT-14WT-14WT-14WT- 14WT-14WT-20WT-20WT-201/21/21/21/21/21/2 1/21/2 Inlet & Outlet(NPT) (in)3/43/43/43/43/43/43/43/4 Temp Control(NPT) (in)Tankless Heater1 1/4 (circulator flange)not applicablenot applicablenot applicable1 1/4 (circulator flange)1 1/4 (circulator flange)1 1/2 (circulator flange)1 1/2 (circulator flange)

5 Model**Heating Net RatingSDraft Loss ThroughRound (in.)Height (ft.)Approx. Shipping(MBH) (2) (3)(MBH) (3) (5) boiler (in w/c) wtgo -3LR9875 wtgo -3RD11285 wtgo -4RD140107 wtgo -5RD168129 wtgo -6RD196150 wtgo -7RD224171 wtgo -8322231 (4) wtgo -9357257 (4)GPH (1)Minimum Chimney Size Weight (Lbs)Rectangular (in.)ENERGY STAR* wtgo -3L13399 wtgo -3133100 wtgo -4168126 wtgo -5203152 wtgo -6245184 wtgo -75405956457608609301,0301, **MBH (3) Rating AHRI Certified RatingsCapacity Tankless Rating (6)IntermittentWM1905_BRO_016_WTGORATING ST appingSizeB2E3 HLNR11 1/21/23/43/41/23/4 Alternate return A units onlyPressure / temperature gaugeDrain valveHigh limit / circulator controlPiping to expansion tank or automatic air ventRelief valve(inches)LocationControlTappings*ENE RGY STAR compliant with Version boiler Specification of 87% AFUE only when installed at the reduced burner rate (R) and with the optional vent damper kit (D).

6 Burners shipped with standard rate nozzle, reduced rates achieved through nozzle change-refer to burner instructions or boiler s rating label for correct selection.*In the interest of continual improvements in product and performance, Weil-McLain reserves the right to change specifications without notice.